Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Impact of personalized alignment technique on implant components position in total knee arthroplasty

View through CrossRef
Introduction Due to substantial rates of dissatisfaction in patients with mechanical alignment in total knee replacement, surgeons began searching for alternative techniques to improve functional outcome. In the recent decade, kinematic alignment that is not based on the mechanical axis of the femur has become the most popular alternative to mechanical alignment. Kinematic alignment technique development has led to creation of a personalized alignment technique.Purpose To compare postoperative implant positions in full-length standing lower-leg radiographs between kinematic alignment and mechanical alignment groups of patients.Materials and methods A prospective, single-center, randomized, controlled study was performed in 139 patients with grade 3–4 knee osteoarthritis (Kellgren – Lawrence). We collected data from 76 cases of mechanical alignment (66 women and 10 men) and 83 cases of personalized alignment group (60 women and 23 men). There were no patients with significant post-traumatic or other deformities of the lower limb which can alter the results in the study. All measurements were done on digital full-length standing X-rays of the lower legs with special MediCAD software.Results The positions of the implant components in mechanical and personalized alignments did not differ significantly in many parameters after operations, despite the fact that the alignment was based on completely different principles. There were no differences between the average values of the angles after operations with mechanical and anatomical axes of the femur in both study groups (the difference was 0.1° at p = 0.595). The only difference in the groups was the position of the tibial component in relation to the horizontal surface in the standing position: in personalized alignment, the angle was 0.9°, and in mechanical alignment it was 2.4° valgus (p < 0.001).Discussion The absence of significant difference in the postoperative leg alignment and implant position except in the joint line orientation between the groups demonstrates possibility to achieve good leg alignment with both techniques. In the personalized alignment group, the joint line orientation in the coronal plane was found nearly parallel to the ground which can result in a more balanced weight distribution compared to mechanical alignment.Conclusion In patients who receive total knee replacement with the personalized technique, the postoperative lower limb alignment was found within the safe boundaries of 3° from the mechanical axis while the joint line orientation in the coronal plane was significantly closer to be parallel with the ground compared with mechanical alignment group.
Russian Ilizarov Scientific Centre Restorative Traumatology and Orthopaedics
Title: Impact of personalized alignment technique on implant components position in total knee arthroplasty
Description:
Introduction Due to substantial rates of dissatisfaction in patients with mechanical alignment in total knee replacement, surgeons began searching for alternative techniques to improve functional outcome.
In the recent decade, kinematic alignment that is not based on the mechanical axis of the femur has become the most popular alternative to mechanical alignment.
Kinematic alignment technique development has led to creation of a personalized alignment technique.
Purpose To compare postoperative implant positions in full-length standing lower-leg radiographs between kinematic alignment and mechanical alignment groups of patients.
Materials and methods A prospective, single-center, randomized, controlled study was performed in 139 patients with grade 3–4 knee osteoarthritis (Kellgren – Lawrence).
We collected data from 76 cases of mechanical alignment (66 women and 10 men) and 83 cases of personalized alignment group (60 women and 23 men).
There were no patients with significant post-traumatic or other deformities of the lower limb which can alter the results in the study.
All measurements were done on digital full-length standing X-rays of the lower legs with special MediCAD software.
Results The positions of the implant components in mechanical and personalized alignments did not differ significantly in many parameters after operations, despite the fact that the alignment was based on completely different principles.
There were no differences between the average values of the angles after operations with mechanical and anatomical axes of the femur in both study groups (the difference was 0.
1° at p = 0.
595).
The only difference in the groups was the position of the tibial component in relation to the horizontal surface in the standing position: in personalized alignment, the angle was 0.
9°, and in mechanical alignment it was 2.
4° valgus (p < 0.
001).
Discussion The absence of significant difference in the postoperative leg alignment and implant position except in the joint line orientation between the groups demonstrates possibility to achieve good leg alignment with both techniques.
In the personalized alignment group, the joint line orientation in the coronal plane was found nearly parallel to the ground which can result in a more balanced weight distribution compared to mechanical alignment.
Conclusion In patients who receive total knee replacement with the personalized technique, the postoperative lower limb alignment was found within the safe boundaries of 3° from the mechanical axis while the joint line orientation in the coronal plane was significantly closer to be parallel with the ground compared with mechanical alignment group.

Related Results

The Influence of Kinematic Alignment on Patellofemoral Joint Biomechanics in Total Knee Arthroplasty
The Influence of Kinematic Alignment on Patellofemoral Joint Biomechanics in Total Knee Arthroplasty
Background: Anterior knee pain is a prevalent issue post total knee arthroplasty, often necessitating revision surgery. Various factors contribute to this complication, including p...
Sex-specific versus standard posterior cruciate-substituting total knee prosthesis
Sex-specific versus standard posterior cruciate-substituting total knee prosthesis
Background The introduction of sex-specific (SS) knee prosthesis designs was an approach to offer more sizing options and is based on the anatomic sex differences. Thes...
Midterm Outcomes of Posterior Cruciate Ligament Substituting Total Knee Arthroplasty
Midterm Outcomes of Posterior Cruciate Ligament Substituting Total Knee Arthroplasty
Objective: In the present study, it is aimed to retrospectively investigate and present the midterm results of the cases with posterior cruciate ligament (PCL) substituting total k...
Investigating Pre-Operative Joint-Level Biomechanics in Partial versus Total Knee Arthroplasty
Investigating Pre-Operative Joint-Level Biomechanics in Partial versus Total Knee Arthroplasty
BackgroundWhile knee osteoarthritis (OA) is incurable, end-stage OA can be managed surgically with partial knee arthroplasty (PKA) or total knee arthroplasty (TKA). Most studies th...
Hip Functions in Patients with Rotating Hinge Knee Arthroplasty
Hip Functions in Patients with Rotating Hinge Knee Arthroplasty
Abstract Background Rotating hinged knee prosthesis is frequently used for certain indications. The indications and results for rotating hinge knee prosthesis in primary an...
Frequency of Anterior Knee Pain (AKP) in Different Gender Groups after Total Knee Replacement (TKR)
Frequency of Anterior Knee Pain (AKP) in Different Gender Groups after Total Knee Replacement (TKR)
Introduction: Anterior Knee Pain (AKP) is one of the most common causes of persistent problems after knee replacement. Total Knee Arthroplasty (TKA) is a surgical procedure in whic...
Reliability and Validity of a Chinese Version of the Lysholm Score and Tegner Activity Scale for Knee Arthroplasty
Reliability and Validity of a Chinese Version of the Lysholm Score and Tegner Activity Scale for Knee Arthroplasty
Objective: To verify the reliability and validity of Chinese versions of the Lysholm score and the Tegner activity scale for knee arthroplasty.Methods: Sixty-four patients undergoi...
Investigating the Correlations between Patient Demographics and Complications Following Total Knee Arthroplasty: A Cross-Sectional Study
Investigating the Correlations between Patient Demographics and Complications Following Total Knee Arthroplasty: A Cross-Sectional Study
Introduction: This study investigates the relationship between patient age, gender, and various complications, such as pain, restricted range of motion (ROM), and hemorrhage follow...

Back to Top