Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Three‐dimensional evaluation of the holographic projection in digital dental model superimposition using HoloLens device

View through CrossRef
Structured AbstractObjectiveTo assess validity and reliability of palatal superimposition of holograms of 3D digital dental models using a customized software, (Ortho Mechanics Sequential Analyzer OMSA), installed on Microsoft HoloLens device as compared to the OMSA application running on a regular computer screen.MethodsThe sample consisted of pre‐ and post‐treatment digital maxillary dental models of 20 orthodontic cases (12.3 ± 1.9 years) treated by rapid maxillary expansion (two turns per day). For each case, the pre‐ and post‐treatment digital models were superimposed using hand gestures for marking the dental models holograms in mixed reality using the Microsoft HoloLens. The same models were then superimposed using the conventional landmark‐based method with OMSA software running on a regular computer screen. The same set of dental arch parameters was measured on the superimposed 3D data by the two software versions for comparison. Agreement in the superimposition outcomes among the two superimposition methods was assessed using Dahlberg error (DE), concordance correlation coefficients (CCCs) using two‐way ANOVA mixed model for absolute agreement and Bland‐Altman analysis.ResultsRepeatability was acceptable for all variables based on the high values of CCCs over 0.99 with a lower 95% confidence limit over 0.95 for any variable. The DE ranged from 0.14 mm to 0.36 mm. The absolute error did not exceed 0.5 mm for any variable.ConclusionUsing the depth vision capabilities of the Microsoft HoloLens, 3D digital dental models can be reliably superimposed allowing virtual assessment of orthodontic treatment outcomes.
Title: Three‐dimensional evaluation of the holographic projection in digital dental model superimposition using HoloLens device
Description:
Structured AbstractObjectiveTo assess validity and reliability of palatal superimposition of holograms of 3D digital dental models using a customized software, (Ortho Mechanics Sequential Analyzer OMSA), installed on Microsoft HoloLens device as compared to the OMSA application running on a regular computer screen.
MethodsThe sample consisted of pre‐ and post‐treatment digital maxillary dental models of 20 orthodontic cases (12.
3 ± 1.
9 years) treated by rapid maxillary expansion (two turns per day).
For each case, the pre‐ and post‐treatment digital models were superimposed using hand gestures for marking the dental models holograms in mixed reality using the Microsoft HoloLens.
The same models were then superimposed using the conventional landmark‐based method with OMSA software running on a regular computer screen.
The same set of dental arch parameters was measured on the superimposed 3D data by the two software versions for comparison.
Agreement in the superimposition outcomes among the two superimposition methods was assessed using Dahlberg error (DE), concordance correlation coefficients (CCCs) using two‐way ANOVA mixed model for absolute agreement and Bland‐Altman analysis.
ResultsRepeatability was acceptable for all variables based on the high values of CCCs over 0.
99 with a lower 95% confidence limit over 0.
95 for any variable.
The DE ranged from 0.
14 mm to 0.
36 mm.
The absolute error did not exceed 0.
5 mm for any variable.
ConclusionUsing the depth vision capabilities of the Microsoft HoloLens, 3D digital dental models can be reliably superimposed allowing virtual assessment of orthodontic treatment outcomes.

Related Results

Awareness of Dental Personnel towards Occupational Injury- A Cross Sectional Study
Awareness of Dental Personnel towards Occupational Injury- A Cross Sectional Study
TITLE: Awareness of dental personnel towards occupational injury- a cross sectional study ABSTRACT Objective: To determine the awareness of dental personnel towards dental occup...
Access Denied
Access Denied
Introduction As social-distancing mandates in response to COVID-19 restricted in-person data collection methods such as participant observation and interviews, researchers turned t...
Guest Editorial
Guest Editorial
Dental caries is one of the major health problems in Indonesia. Data from Indonesian Basic Health Research in 2013, 2015 and 2018 showed a consistent increase in the prevalence of ...
Management of Oblique Root Fracture Using Mineral Trioxide Aggregate: A Case Report
Management of Oblique Root Fracture Using Mineral Trioxide Aggregate: A Case Report
Root fractures are relatively uncommon compared to other types of dental traumas. It is sometimes extremely difficult for practitioners to decide what should be done and which appr...
The Holographic Human for Surgical Navigation using Microsoft HoloLens
The Holographic Human for Surgical Navigation using Microsoft HoloLens
In surgical navigation, to accurately know the position of a surgical instrument in a patient's body is very important. Using transparent smart glasses is very useful for surgical ...
Delivering clinical tutorials to medical students using the Microsoft HoloLens 2: A mixed-methods evaluation
Delivering clinical tutorials to medical students using the Microsoft HoloLens 2: A mixed-methods evaluation
Abstract Background Mixed reality offers potential educational advantages in the delivery of clinical teaching. Holographic artefacts can be rendere...
Comparison of prevalence of symptoms of carpal tunnel syndrome between dental students and dental practitioners - A cross-sectional study
Comparison of prevalence of symptoms of carpal tunnel syndrome between dental students and dental practitioners - A cross-sectional study
Background: carpal tunnel syndrome (CTS) arises from compression of the median nerve when it passes through the carpal tunnel in the wrist. Dental professionals use vibratory instr...
Optical Methods for the Measurement of the Temperature and Concentration Distribution in Combustion Chambers
Optical Methods for the Measurement of the Temperature and Concentration Distribution in Combustion Chambers
<div class="htmlview paragraph">Two kinds of optical methods for the measurement of the temperature and concentration distribution in combustion chambers by means of the real...

Back to Top