McMillan electron lens in a system with space charge
View through CrossRef
Abstract
Space charge (SC) forces of a circulating beam in a ring
have both linear (defocusing) and nonlinear components, due to a
nonuniform beam distribution. The linear component of SC forces
produces a betatron tune shift, which is the largest for a
zero-amplitude particle, while the nonlinear component produces an
amplitude-dependent betatron tune spread. These SC effects are
responsible for several undesirable phenomena in accelerators:
emittance growth, particle losses, beam halo, etc. In this paper,
we investigate the possibility to mitigate the distributed SC forces
by a thin McMillan lens, providing an axially-symmetric kick, which
is qualitatively opposite to the accumulated effect of beam's own
SC. Experimentally, the proposed concept can be tested in Fermilab's
IOTA ring. A thin McMillan lens can be implemented by a short
(70) insertion of an electron beam with a specifically
chosen density distribution in transverse directions. In this
article, to test if McMillan lenses can reduce the tune spread
induced by SC, we make several simulations with a 6-D particle
tracking code, Synergia. We choose such beam and lattice parameters
that the SC tune spread is roughly 0.5 and the emittance growth due
to the half-integer resonance is clearly observed without the SC
compensation. Then, we focus on reducing the emittance growth by
adjusting the bare betatron tunes using the ring quadrupoles, and
reducing the tune spread by the McMillan lenses. The results of
reducing a large tune spread (≈ 0.5), reported here, are not
perfect, but substantial. There is still room for further
investigation. The simulations performed so far indicate that
McMillan lenses can cope with an SC tune spread of ≈ 0.1 per
lens.
Title: McMillan electron lens in a system with space charge
Description:
Abstract
Space charge (SC) forces of a circulating beam in a ring
have both linear (defocusing) and nonlinear components, due to a
nonuniform beam distribution.
The linear component of SC forces
produces a betatron tune shift, which is the largest for a
zero-amplitude particle, while the nonlinear component produces an
amplitude-dependent betatron tune spread.
These SC effects are
responsible for several undesirable phenomena in accelerators:
emittance growth, particle losses, beam halo, etc.
In this paper,
we investigate the possibility to mitigate the distributed SC forces
by a thin McMillan lens, providing an axially-symmetric kick, which
is qualitatively opposite to the accumulated effect of beam's own
SC.
Experimentally, the proposed concept can be tested in Fermilab's
IOTA ring.
A thin McMillan lens can be implemented by a short
(70) insertion of an electron beam with a specifically
chosen density distribution in transverse directions.
In this
article, to test if McMillan lenses can reduce the tune spread
induced by SC, we make several simulations with a 6-D particle
tracking code, Synergia.
We choose such beam and lattice parameters
that the SC tune spread is roughly 0.
5 and the emittance growth due
to the half-integer resonance is clearly observed without the SC
compensation.
Then, we focus on reducing the emittance growth by
adjusting the bare betatron tunes using the ring quadrupoles, and
reducing the tune spread by the McMillan lenses.
The results of
reducing a large tune spread (≈ 0.
5), reported here, are not
perfect, but substantial.
There is still room for further
investigation.
The simulations performed so far indicate that
McMillan lenses can cope with an SC tune spread of ≈ 0.
1 per
lens.
Related Results
Comparative Clinical Performance of Rigid versus Soft Hyper Dk Contact Lenses Used for Continuous Wear
Comparative Clinical Performance of Rigid versus Soft Hyper Dk Contact Lenses Used for Continuous Wear
ABSTRACT
Purpose.
The purpose of this study is to investigate the comparative clinical performance of two hyper Dk contac...
Morphometric OCT parameters of the lens under accommodative stimulus. Report 1. Assessment of age-related changes
Morphometric OCT parameters of the lens under accommodative stimulus. Report 1. Assessment of age-related changes
Introduction. The structural approach to studying the mechanism of accommodation and its age-related changes focuses on analyzing morphometric parameters (size, shape, and position...
H atom parameters: how Classical Physics gives new/clear results
H atom parameters: how Classical Physics gives new/clear results
In our recent paper [A. Bacchieri, Phys. Essays 36, 61 (2023)], we had found that the total escape speed from all the masses in the universe, u = (‐2 u)1/2, where u is the total gr...
Seditious Spaces
Seditious Spaces
The title ‘Seditious Spaces’ is derived from one aspect of Britain’s colonial legacy in Malaysia (formerly Malaya): the Sedition Act 1948. While colonial rule may seem like it was ...
Structural and functional features of the eye in Marfan syndrome. Report 2. Changes in the anatomical complex of the lens
Structural and functional features of the eye in Marfan syndrome. Report 2. Changes in the anatomical complex of the lens
Analysis of lens changes in Marfan syndrome (MS), in addition to assessing the position of the lens itself, should include the possibility of examining its supporting and accommoda...
Morphology Effects on Space Charge Characteristics of Low Density Polyethylene
Morphology Effects on Space Charge Characteristics of Low Density Polyethylene
Low density polyethylene (LDPE) film samples with different morphology were prepared by three kinds of annealing methods which were different in cooling rates in this study. A puls...
Lists, Spatial Practice and Assistive Technologies for the Blind
Lists, Spatial Practice and Assistive Technologies for the Blind
IntroductionSupermarkets are functionally challenging environments for people with vision impairments. A supermarket is likely to house an average of 45,000 products in a median fl...
Molecular Genetics of Cataract
Molecular Genetics of Cataract
Abstract
Cataract can be defined as any opacity or cloudiness of the crystalline lens. When there is significant variation of the refractive ind...