In Silico and in Vitro Development of a New Bipolar Radiofrequency Ablation Device for Renal Denervation

View through CrossRef
Abstract Background: Renal denervation with radiofrequency ablation has become an accepted treatment for drug-resistant hypertension. However, there is a continuing need to develop new catheters for high-accuracy, targeted ablation. We, therefore, developed a radiofrequency ablation device with a basket catheter and bipolar electrodes for controlled, targeted ablation through Joule heating induction between 60°C and 100°C.Methods: Finite element modeling was used to determine the optimum catheter design to deliver a minimum ablation zone of 4 mm (W) x 10 mm (L) x 4 mm (H) within 60 seconds with a 500 kHz, 60 Vp-p signal, and 0.9 W maximum. The computational model was validated using in vitro phantom tissue impregnated with a color-changing thermochromic pigment.Results: The in vitro ablation zone closely matched the size and shape of the simulated area. The new electrode design directs the current density towards the artery walls and tissue, reducing unwanted blood temperature increases by focusing energy on the ablation zone. In contrast, the basket catheter design does not block renal flow during renal denervation.Conclusions: This computational model of radiofrequency ablation can be used to estimate renal artery ablation zones for highly targeted renal denervation in patients with resistant hypertension. Furthermore, this innovative catheter has short ablation times and the lowest power requirement of existing designs to perform the ablation.
Title: In Silico and in Vitro Development of a New Bipolar Radiofrequency Ablation Device for Renal Denervation
Description:
Abstract Background: Renal denervation with radiofrequency ablation has become an accepted treatment for drug-resistant hypertension.
However, there is a continuing need to develop new catheters for high-accuracy, targeted ablation.
We, therefore, developed a radiofrequency ablation device with a basket catheter and bipolar electrodes for controlled, targeted ablation through Joule heating induction between 60°C and 100°C.
Methods: Finite element modeling was used to determine the optimum catheter design to deliver a minimum ablation zone of 4 mm (W) x 10 mm (L) x 4 mm (H) within 60 seconds with a 500 kHz, 60 Vp-p signal, and 0.
9 W maximum.
The computational model was validated using in vitro phantom tissue impregnated with a color-changing thermochromic pigment.
Results: The in vitro ablation zone closely matched the size and shape of the simulated area.
The new electrode design directs the current density towards the artery walls and tissue, reducing unwanted blood temperature increases by focusing energy on the ablation zone.
In contrast, the basket catheter design does not block renal flow during renal denervation.
Conclusions: This computational model of radiofrequency ablation can be used to estimate renal artery ablation zones for highly targeted renal denervation in patients with resistant hypertension.
Furthermore, this innovative catheter has short ablation times and the lowest power requirement of existing designs to perform the ablation.

Related Results

Microwave Ablation with or Without Chemotherapy in Management of Non-Small Cell Lung Cancer: A Systematic Review
Microwave Ablation with or Without Chemotherapy in Management of Non-Small Cell Lung Cancer: A Systematic Review
Abstract Introduction  Microwave ablation (MWA) has emerged as a minimally invasive treatment for patients with inoperable non-small cell lung cancer (NSCLC). However, whether it i...
Imaging-derived tissue visualization guides catheter ablation of premature ventricular contractions
Imaging-derived tissue visualization guides catheter ablation of premature ventricular contractions
Abstract Background The presence of myocardial scarring is associated with worse outcomes after catheter ablation of premature v...
Sympathetic renal denervation treatment in resistant hypertension: one-year follow-up
Sympathetic renal denervation treatment in resistant hypertension: one-year follow-up
Abstract Aims A comparison influence of renal denervation versus pharmacological treatment with sympathetic nervous system block...
The advantage of mini electrode-equipped catheter for the radiofrequency ablation of paroxysmal supraventricular tachycardia
The advantage of mini electrode-equipped catheter for the radiofrequency ablation of paroxysmal supraventricular tachycardia
Introduction: Novel ablation catheters equipped with mini-electrodes (ME) offer high resolution mapping for target tissue. This study aimed to evaluate the mappin...
Analisis Penyalahgunaan Zat sebagai Faktor Risiko Kejadian Gangguan Bipolar pada Orang Dewasa
Analisis Penyalahgunaan Zat sebagai Faktor Risiko Kejadian Gangguan Bipolar pada Orang Dewasa
Abstract. Bipolar disorder is an emotional disorder with recurrent episodes of mood swings and depression, followed by changes in activity or energy and associated with characteris...
Neuromodulation in electrical storm: safety and efficacy of renal denervation
Neuromodulation in electrical storm: safety and efficacy of renal denervation
Abstract Background Catheter ablation (CA) has shown efficacy in managing ventricular arrhythmias (VA) associated with structura...
Ablation Performance of C/SiC-ZrC Composites
Ablation Performance of C/SiC-ZrC Composites
Abstract To reveal the ablation performance of C/SiC-ZrC composites under different ablation methods, C/SiC-ZrC composites were prepared by chemical vapor deposition and pr...

Back to Top