Javascript must be enabled to continue!
Performance of Masonry Buildings in St. Peter, Minnesota During the March 29, 1998 Tornadoes
View through CrossRef
Thirteen tornadoes struck southern Minnesota, March 29, 1998. The city of St. Peter, MN and the adjacent campus of Gustavus Adolphus College, were hit by a multi-vortex tornado, classified as F4 on the Fujita scale, with path width and length that exceeded 1 mile (1.6 km) and 17 miles (27 km), respectively. The city of St. Peter and Gustavus Adolphus College have large inventories of masonry buildings with construction dates that span more than one century, several of which were damaged during the storm. A TMS Disaster Investigation team surveyed the performance of masonry buildings in St. Peter and Gustavus Adolphus College, given the large inventory of masonry buildings and news reports of widespread damage. This paper summarizes the data collected by the team, and provides an assessment of masonry building performance during the tornadoes.
The observed performance of masonry buildings was very good, as long as certain undesirable practices were avoided. No apparent trends were found which correlate damage vulnerability with either age of building at the time of the storm or design method used to proportion the building components (that is, engineered vs. empirical). Common instances of structural damage in masonry buildings were related to deficiencies in roof diaphragms and tie-downs to the masonry walls, as well as large unsupported openings in the masonry. Other types of masonry distresses observed include cracking and crushing from projectile impact, parapet uplift and collapse, brick veneer peeling, and loss of coping stones and cladding panels. Nonstructural damage was extensive with many buildings suffering window breakage, water damage and roof damage (loss of shingles and ballast, partial loss of membranes, and damage to coping and flashing, to complete roof lift off and removal).
Title: Performance of Masonry Buildings in St. Peter, Minnesota During the March 29, 1998 Tornadoes
Description:
Thirteen tornadoes struck southern Minnesota, March 29, 1998.
The city of St.
Peter, MN and the adjacent campus of Gustavus Adolphus College, were hit by a multi-vortex tornado, classified as F4 on the Fujita scale, with path width and length that exceeded 1 mile (1.
6 km) and 17 miles (27 km), respectively.
The city of St.
Peter and Gustavus Adolphus College have large inventories of masonry buildings with construction dates that span more than one century, several of which were damaged during the storm.
A TMS Disaster Investigation team surveyed the performance of masonry buildings in St.
Peter and Gustavus Adolphus College, given the large inventory of masonry buildings and news reports of widespread damage.
This paper summarizes the data collected by the team, and provides an assessment of masonry building performance during the tornadoes.
The observed performance of masonry buildings was very good, as long as certain undesirable practices were avoided.
No apparent trends were found which correlate damage vulnerability with either age of building at the time of the storm or design method used to proportion the building components (that is, engineered vs.
empirical).
Common instances of structural damage in masonry buildings were related to deficiencies in roof diaphragms and tie-downs to the masonry walls, as well as large unsupported openings in the masonry.
Other types of masonry distresses observed include cracking and crushing from projectile impact, parapet uplift and collapse, brick veneer peeling, and loss of coping stones and cladding panels.
Nonstructural damage was extensive with many buildings suffering window breakage, water damage and roof damage (loss of shingles and ballast, partial loss of membranes, and damage to coping and flashing, to complete roof lift off and removal).
Related Results
Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Improvement of seismic performance of ordinary reinforced partially grouted concrete masonry shear walls
Reinforced masonry constitutes about 10% of all low-rise construction in the US. Most of these structures are commercial and school buildings. It may also be used for multi-story h...
Comparison of Tornado Damage Characteristics to Low-Altitude WSR-88D Radar Observations and Implications for Tornado Intensity Estimation
Comparison of Tornado Damage Characteristics to Low-Altitude WSR-88D Radar Observations and Implications for Tornado Intensity Estimation
Abstract
Given the obvious difficulties in directly sampling tornadic wind fields, ongoing work continues to improve estimates of near-ground wind speeds in tornadoes. This study b...
The Masonry Market is Booming in Brazil- Why?
The Masonry Market is Booming in Brazil- Why?
This paper is motivated by the keynote presentation at the 12th North American Masonry Conference in Denver, Colorado in 2015. It gives an overview on how engineered masonry became...
Experimental Comparison Between Two-Course Molded Masonry Specimen and Three-Course Extracted Masonry Specimen in Clay Masonry Structures
Experimental Comparison Between Two-Course Molded Masonry Specimen and Three-Course Extracted Masonry Specimen in Clay Masonry Structures
This study investigates the relationship between the compressive strength results of two-course molded masonry specimens and three-course masonry specimens extracted from previousl...
Stress and strain studies of historical masonry
Stress and strain studies of historical masonry
Introduction
. Brick masonry of historical buildings has a number of features compared to masonry made of contemporary materials. This applies to both strength ...
Investigating residual properties of masonry units at elevated temperatures
Investigating residual properties of masonry units at elevated temperatures
Masonry structures are renowned globally for their strength, durability, affordability, and thermal and sound insulation properties. However, there is limited information on the re...
Engineering Design Provisions for Prestressed Masonry, Part 1 – Masonry Stresses
Engineering Design Provisions for Prestressed Masonry, Part 1 – Masonry Stresses
Masonry can be strengthened through controlled precompression stresses which reduce or eliminate tension. In other countries, primarily the United Kingdom, prestressed masonry has ...
Behaviour of Unreinforced Masonry Buildings Subjected to Earthquakes
Behaviour of Unreinforced Masonry Buildings Subjected to Earthquakes
The collapse of unreinforced masonry buildings during an earthquake is the main contributor to the maximum loss of lives and injuries to people and it will continue to be so becaus...

