Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Thermal Performance of Slotted Light Steel-Framed Composite Wall

View through CrossRef
In this study, calibrated hot box and finite element simulation methods were used to study the influence of a slotted web on the thermal performance of a lightweight steel stud composite wall. By comparing the results from the simulations and experiments, the accuracy of the finite element method was verified; this method was then used for parameter analyses. The results showed that the wall’s thermal transfer coefficient is inversely proportional to increases in the length of the slot and height of the stud web, leading to improvements in the thermal insulation effect; vice versa, the wall thermal transfer coefficient increases when the slot transverse spacing and stud thickness increase, and the insulation effect correspondingly worsens. The stud spacing influences the insulation performance of the wall by changing the proportion of studs within a certain wall. The greater the proportion of studs, the greater the stud thermal bridging, the faster the thermal loss, and the worse the insulation effect of the wall. In practice, the height of the stud web can be set as required. Preferably, for practical applications, the number of rows of slots is 5–7, the length of the slots is 70–80 mm, the transverse distance of the slots is 6–8 mm, the thickness of each stud is 1 or 1.2 mm, and the distance of each stud is 600 mm.
Title: Thermal Performance of Slotted Light Steel-Framed Composite Wall
Description:
In this study, calibrated hot box and finite element simulation methods were used to study the influence of a slotted web on the thermal performance of a lightweight steel stud composite wall.
By comparing the results from the simulations and experiments, the accuracy of the finite element method was verified; this method was then used for parameter analyses.
The results showed that the wall’s thermal transfer coefficient is inversely proportional to increases in the length of the slot and height of the stud web, leading to improvements in the thermal insulation effect; vice versa, the wall thermal transfer coefficient increases when the slot transverse spacing and stud thickness increase, and the insulation effect correspondingly worsens.
The stud spacing influences the insulation performance of the wall by changing the proportion of studs within a certain wall.
The greater the proportion of studs, the greater the stud thermal bridging, the faster the thermal loss, and the worse the insulation effect of the wall.
In practice, the height of the stud web can be set as required.
Preferably, for practical applications, the number of rows of slots is 5–7, the length of the slots is 70–80 mm, the transverse distance of the slots is 6–8 mm, the thickness of each stud is 1 or 1.
2 mm, and the distance of each stud is 600 mm.

Related Results

Thermal Effects in High Compactness CEA Stack
Thermal Effects in High Compactness CEA Stack
Thermal management is a pivotal aspect of stack durability and system operability. Consequently, understanding the thermal mapping within a stack based on its operating conditions ...
Structural Behavior And Design Method Of Steel/Concrete Composite Ice Walls for Arctic Offshore Structures
Structural Behavior And Design Method Of Steel/Concrete Composite Ice Walls for Arctic Offshore Structures
ABSTRACT In order to develop an optimum steel/concrete composite ice wall for the arctic offshore structures, structural behavior of the steel/concrete composite ...
Der skal ikke lades sten på sten tilbage
Der skal ikke lades sten på sten tilbage
The Building by the Barbar TempleClose by the large temple at Barbar 1) lies a little tell, which was investigated in the spring of 1956. The tell was shown to cover a building of ...
Composite Slotted Tools from the Kazachka Site (Eastern Siberia)
Composite Slotted Tools from the Kazachka Site (Eastern Siberia)
Composite slotted tools made of bone and antler are a common element in the material culture of the Early Holocene communities across Eurasia, including Eastern Siberia. These tool...
Modal and stress behavioral for CFRP composite lifting lug
Modal and stress behavioral for CFRP composite lifting lug
Purpose In the present study, a steel lifting lug is replaced with a composite (carbon fiber-reinforced epoxy [CFRP]) lifting lug made of a carbon/epoxy composite. The purpose of t...
Wet Gas Measurement with Slotted Orifice Meter--Effect of Geometry of Slots and Pressure
Wet Gas Measurement with Slotted Orifice Meter--Effect of Geometry of Slots and Pressure
Wet gas metering by differential pressure flow meters is gaining prominence in the oil and gas industry, owing to their simple construction. Slotted orifice, a modified version of ...

Back to Top