DjinniChip: Evaluation of a novel molecular rapid diagnostic device for the detection of Chlamydia trachomatis in trachoma-endemic areas

View through CrossRef
Abstract Background The clinical signs of active trachoma are often present in the absence of ocular Chlamydia trachomatis infection, particularly following mass drug administration. Treatment decisions following impact surveys and in post-control surveillance for communities are currently based on the prevalence of clinical signs, which may result in further unnecessary distribution of mass antibiotic treatment and the increased spread of macrolide resistance alleles in ‘off-target’ bacterial species. We therefore developed a simple, fast, low cost diagnostic assay (DjinniChip) for diagnosis of ocular C. trachomatis for use by trachoma control programmes. Methods The study was conducted in London, Germany and Tanzania. For clinical testing in Tanzania, specimens from a sample of 350 children between the ages of 7 to15 years, which were part of a longitudinal cohort that began in February 2012 were selected. Two ocular swabs were taken from the right eye. The second swab was collected dry, kept cool in the field and archived at -80 o C before sample lysis for DjinniChip detection and parallel nucleic acid purification and detection/quantification by qPCR assay. Results Djinnichip was able to reliably detect >10 copies of C. trachomatis per test and correctly identified 7/10 Quality Control for Molecular Diagnostics C. trachomatis panel samples, failing to detect 3 positive samples with genome equivalent amounts >10 copies. Djinnichip performed well across a range of typical trachoma field conditions and when used by lay personnel using a series of mock samples. In the laboratory in Tanzania, using clinical samples the sensitivity and specificity of DjinniChip for C. trachomatis was 66% (95% CI 51–78) and 94.8 (95% CI 91–97%) with an overall accuracy of 90.1 (95% CI 86.4 – 93). Conclusions DjinniChip performance is extremely promising, particularly its ability to detect low concentrations of C. trachomatis and its usability in field conditions. The DjinniChip requires further development to reduce inhibition and advance toward a closed system. DjinniChip results did not vary between local laboratory results and typical trachoma field settings, illustrating its potential for use in low-resource areas to prevent unnecessary rounds of MDA and to monitor for C. trachomatis recrudescence.
Title: DjinniChip: Evaluation of a novel molecular rapid diagnostic device for the detection of Chlamydia trachomatis in trachoma-endemic areas
Description:
Abstract Background The clinical signs of active trachoma are often present in the absence of ocular Chlamydia trachomatis infection, particularly following mass drug administration.
Treatment decisions following impact surveys and in post-control surveillance for communities are currently based on the prevalence of clinical signs, which may result in further unnecessary distribution of mass antibiotic treatment and the increased spread of macrolide resistance alleles in ‘off-target’ bacterial species.
We therefore developed a simple, fast, low cost diagnostic assay (DjinniChip) for diagnosis of ocular C.
trachomatis for use by trachoma control programmes.
Methods The study was conducted in London, Germany and Tanzania.
For clinical testing in Tanzania, specimens from a sample of 350 children between the ages of 7 to15 years, which were part of a longitudinal cohort that began in February 2012 were selected.
Two ocular swabs were taken from the right eye.
The second swab was collected dry, kept cool in the field and archived at -80 o C before sample lysis for DjinniChip detection and parallel nucleic acid purification and detection/quantification by qPCR assay.
Results Djinnichip was able to reliably detect >10 copies of C.
trachomatis per test and correctly identified 7/10 Quality Control for Molecular Diagnostics C.
trachomatis panel samples, failing to detect 3 positive samples with genome equivalent amounts >10 copies.
Djinnichip performed well across a range of typical trachoma field conditions and when used by lay personnel using a series of mock samples.
In the laboratory in Tanzania, using clinical samples the sensitivity and specificity of DjinniChip for C.
trachomatis was 66% (95% CI 51–78) and 94.
8 (95% CI 91–97%) with an overall accuracy of 90.
1 (95% CI 86.
4 – 93).
Conclusions DjinniChip performance is extremely promising, particularly its ability to detect low concentrations of C.
trachomatis and its usability in field conditions.
The DjinniChip requires further development to reduce inhibition and advance toward a closed system.
DjinniChip results did not vary between local laboratory results and typical trachoma field settings, illustrating its potential for use in low-resource areas to prevent unnecessary rounds of MDA and to monitor for C.
trachomatis recrudescence.

Related Results

Prevalence of Chlamydia trachomatis and Candida albicans ; hospital based study
Prevalence of Chlamydia trachomatis and Candida albicans ; hospital based study
Abstract Background Chlamydia and candidiasis have only mild or no symptoms at all. When symptoms develop, they are often mista...
The relationship between male factor infertility and Chlamydia infection, still an undecided issue
The relationship between male factor infertility and Chlamydia infection, still an undecided issue
Background: Seropositivity of Chlamydia trachomatis in men is suggestive of chronic and recurrent infection with this sexually transmitted organism. Most males with urogenital Chla...
Prevalence of Ocular Chlamydia trachomatis Infection in Amhara Region, Ethiopia, after 8 Years of Trachoma Control Interventions
Prevalence of Ocular Chlamydia trachomatis Infection in Amhara Region, Ethiopia, after 8 Years of Trachoma Control Interventions
ABSTRACT. Although trachoma mass drug administration (MDA) programs target ocular Chlamydia trachomatis, the global trachoma control program does not monitor infection as a measure...
Trachoma risk factors in Oromia Region, Ethiopia
Trachoma risk factors in Oromia Region, Ethiopia
Background Trachoma, the leading infectious cause of blindness, is caused by the bacterium Chlamydia trachomatis (Ct). Despite enormous disease control efforts and encouraging prog...
Prevalence and associations of active trachoma among rural preschool children in Wadla district, northern Ethiopia
Prevalence and associations of active trachoma among rural preschool children in Wadla district, northern Ethiopia
Abstract Background ፡ Trachoma is a neglected eye problem and an important cause of preventable corneal blindness. In endemic areas, initial infection can occur in early ch...
Prevalence and associations of active trachoma among rural preschool children in Wadla district, Northern Ethiopia
Prevalence and associations of active trachoma among rural preschool children in Wadla district, Northern Ethiopia
Abstract Background፡Trachoma is a neglected eye infection and important cause of preventable corneal blindness. In endemic areas, initial infection can occur in early child...

Back to Top