Using Optic Sensors for Near-Continuous Water Quality Monitoring of Stormwater Runoff

View through CrossRef
Highlights Spectrophotometers enabled water quality monitoring for 96% of the runoff volume recorded during the study at a high frequency of 4 minutes, providing insights into pollutant dynamics. Local calibration of spectrophotometers proved more challenging in the stormwater context than the previously reported perennial streams due to inherent flashy flows and concentrations, resulting in limited representation of high-concentration local samples and an unstable relationship between the water color matrix and concentrations. Using instrument-reported to lab-reported concentration regressions (SLR), the annual nitrate, DOC, and TSS loads were estimated within an uncertainty range of ±10%, and within ±16% using absorbance to lab-reported concentration regressions (PSLR). Event load estimation using spectrophotometers had uncertainty estimated within ±10% around the mean for nitrate and DOC loads using the best calibrations for 90% of the events. Much higher uncertainties, between 40 and 60%, were observed for TSS. ABSTRACT. This paper presents methods, challenges, and uncertainties associated with using spectrophotometers for continuous stormwater water quality monitoring. Spectrophotometer sensors, proven insightful in other fields of hydrological research, were tested for monitoring the inflow to a constructed stormwater wetland. These sensors allowed for water quality monitoring at a 4-minute frequency, providing insight into pollutant dynamics, and enabled 95% of total recorded inflow volume to be sampled over 20 months of study. The main challenge of using spectrophotometers in non-sewer stormwater was instrument calibration due to inherently flashy flows and generally low concentration ranges of nitrate. To calibrate the sensor, local samples were collected by autosamplers and analyzed in the laboratory. Two local calibration methods were tested: simple linear regressions (SLR) between instrument and lab concentrations and partial least square regressions (PLSR) between the absorbance spectra and lab concentrations. The resulting annual and event loads were used to estimate the uncertainties associated with each regression model. The observed uncertainties were due to the (1) regression type, (2) uniformity of concentration range represented in calibration samples, and (3) presence or absence of stratification in the calibration samples. Stratified samples yielded lowest uncertainty for both calibration models. SLR model offered lower uncertainty ranges than PLSR for estimation of both annual and event loads for stormwater. Keywords: High-frequency stormwater sampling, Monitoring uncertainties, Near-continuous stormwater sampling, Spectrophotometer in stormwater, Stormwater monitoring, Stormwater pollutant dynamics.
Title: Using Optic Sensors for Near-Continuous Water Quality Monitoring of Stormwater Runoff
Description:
Highlights Spectrophotometers enabled water quality monitoring for 96% of the runoff volume recorded during the study at a high frequency of 4 minutes, providing insights into pollutant dynamics.
Local calibration of spectrophotometers proved more challenging in the stormwater context than the previously reported perennial streams due to inherent flashy flows and concentrations, resulting in limited representation of high-concentration local samples and an unstable relationship between the water color matrix and concentrations.
Using instrument-reported to lab-reported concentration regressions (SLR), the annual nitrate, DOC, and TSS loads were estimated within an uncertainty range of ±10%, and within ±16% using absorbance to lab-reported concentration regressions (PSLR).
Event load estimation using spectrophotometers had uncertainty estimated within ±10% around the mean for nitrate and DOC loads using the best calibrations for 90% of the events.
Much higher uncertainties, between 40 and 60%, were observed for TSS.
ABSTRACT.
This paper presents methods, challenges, and uncertainties associated with using spectrophotometers for continuous stormwater water quality monitoring.
Spectrophotometer sensors, proven insightful in other fields of hydrological research, were tested for monitoring the inflow to a constructed stormwater wetland.
These sensors allowed for water quality monitoring at a 4-minute frequency, providing insight into pollutant dynamics, and enabled 95% of total recorded inflow volume to be sampled over 20 months of study.
The main challenge of using spectrophotometers in non-sewer stormwater was instrument calibration due to inherently flashy flows and generally low concentration ranges of nitrate.
To calibrate the sensor, local samples were collected by autosamplers and analyzed in the laboratory.
Two local calibration methods were tested: simple linear regressions (SLR) between instrument and lab concentrations and partial least square regressions (PLSR) between the absorbance spectra and lab concentrations.
The resulting annual and event loads were used to estimate the uncertainties associated with each regression model.
The observed uncertainties were due to the (1) regression type, (2) uniformity of concentration range represented in calibration samples, and (3) presence or absence of stratification in the calibration samples.
Stratified samples yielded lowest uncertainty for both calibration models.
SLR model offered lower uncertainty ranges than PLSR for estimation of both annual and event loads for stormwater.
Keywords: High-frequency stormwater sampling, Monitoring uncertainties, Near-continuous stormwater sampling, Spectrophotometer in stormwater, Stormwater monitoring, Stormwater pollutant dynamics.

Related Results

Stormwater Runoff Quality from Different Surfaces in an Urban Catchment in Beijing, China
Stormwater Runoff Quality from Different Surfaces in an Urban Catchment in Beijing, China
Urban stormwater runoff quality, widely investigated around the world, has been monitored less in Beijing, China, which impedes the municipal government to use best management prac...
A Data-Driven Approach to Stormwater Quality Analysis in Two Urban Catchments
A Data-Driven Approach to Stormwater Quality Analysis in Two Urban Catchments
The StormTac Web model, representing a low-complexity conceptual model (LCCM), was applied to two urban catchments featuring stormwater quality controls, a stormwater pond or a bio...
Green Street: Landscape Design Approach to Street Stormwater Management
Green Street: Landscape Design Approach to Street Stormwater Management
Stormwater is a resource, but the traditional stormwater management practices treat it as a waste and cause many problems. Green Street is a new method to manage the street stormwa...
Indicator-based Hydrological Resilience Framework for Urban Stormwater Management Systems
Indicator-based Hydrological Resilience Framework for Urban Stormwater Management Systems
Abstract Urbanisation changes the nature of urban catchments by altering landcover, soil conditions and runoff storage capacity, resulting in increased runoff volume and pe...

Back to Top