Voltammetric Method Development for Itopride Assay in a Pharmaceutical Formulation
View through CrossRef
Background:
Itopride used for the gastrointestinal symptoms caused by reduced gastrointestinal
mobility. For the first time rapid, low cost and green voltammetric method has been applied to
analyze itopride in pharmaceutical formulation.
Method:
Cyclic Voltammetry (CV), Linear Sweep Voltammetry (LSV), Square Wave Voltammetry
(SWV) and Differential Pulse Voltammetry (DPV) methods have been applied in this study.
Results:
Na2SO4 (1M) supporting electrolyte exhibited sharper anodic peak current than other used
supporting electrolytes; glassy carbon electrode (GC) working electrode shows better results than platinum
electrode (Pt). SWV results show the lowest limit of detection and quantitation values of 2.3 and
18.1 μg.mL-1, respectively. SWV recovery is 100.56% and 100.46% for 50 μg.mL-1 and 100 μg.mL-1
of commercially available itopride tablets, respectively. Furthermore, SWV inter and intraday results
precessions are better than other used methods with 0.96 and 0.56% RSD, respectively.
Conclusion:
The optimum method of applied methods in this study is SWV method. Voltammetry
showed low LOD and LOQ values with high accuracy and precession in addition to comparable repeatability
and reproducibility values.
Title: Voltammetric Method Development for Itopride Assay in a Pharmaceutical Formulation
Description:
Background:
Itopride used for the gastrointestinal symptoms caused by reduced gastrointestinal
mobility.
For the first time rapid, low cost and green voltammetric method has been applied to
analyze itopride in pharmaceutical formulation.
Method:
Cyclic Voltammetry (CV), Linear Sweep Voltammetry (LSV), Square Wave Voltammetry
(SWV) and Differential Pulse Voltammetry (DPV) methods have been applied in this study.
Results:
Na2SO4 (1M) supporting electrolyte exhibited sharper anodic peak current than other used
supporting electrolytes; glassy carbon electrode (GC) working electrode shows better results than platinum
electrode (Pt).
SWV results show the lowest limit of detection and quantitation values of 2.
3 and
18.
1 μg.
mL-1, respectively.
SWV recovery is 100.
56% and 100.
46% for 50 μg.
mL-1 and 100 μg.
mL-1
of commercially available itopride tablets, respectively.
Furthermore, SWV inter and intraday results
precessions are better than other used methods with 0.
96 and 0.
56% RSD, respectively.
Conclusion:
The optimum method of applied methods in this study is SWV method.
Voltammetry
showed low LOD and LOQ values with high accuracy and precession in addition to comparable repeatability
and reproducibility values.
Related Results
Selection of Injectable Drug Product Composition using Machine Learning Models (Preprint)
Selection of Injectable Drug Product Composition using Machine Learning Models (Preprint)
BACKGROUND
As of July 2020, a Web of Science search of “machine learning (ML)” nested within the search of “pharmacokinetics or pharmacodynamics” yielded over 100...
Application and Progress of Chemometrics in Voltammetric Biosensing
Application and Progress of Chemometrics in Voltammetric Biosensing
The voltammetric electrochemical sensing method combined with biosensors and multi-sensor systems can quickly, accurately, and reliably analyze the concentration of the main analyt...
ASP Formulation Development Journey, Optimisation and Validation for Mangala Field
ASP Formulation Development Journey, Optimisation and Validation for Mangala Field
Abstract
Mangala is a large low salinity, high quality fluvial oil field reservoir in India with STOIIP of over one billion barrels of waxy and moderately viscous cr...
Prostate‐specific antigen assay using whole blood samples spotted on filter paper and its application to mass screening for prostate cancer
Prostate‐specific antigen assay using whole blood samples spotted on filter paper and its application to mass screening for prostate cancer
Aim: The disc assay system for prostate‐specific antigen (PSA) is a novel technique using a small amount of whole blood on filter paper. The accuracy of this assay system and its ...
Welcome to Pharmaceutical Communications
Welcome to Pharmaceutical Communications
Welcome to the inaugural issue of Pharmaceutical Communications-a biannual, open access, and peer-reviewed journal aiming to publish high-quality research articles in the field of ...
Corporate social responsibility of pharmaceutical industry in Korea
Corporate social responsibility of pharmaceutical industry in Korea
Background: Global pharmaceutical companies in Korea argue that the development of innovative drugs should be recognized as a social contribution, yet it has been countered by vari...
Cellex qCoV Protocol v2
Cellex qCoV Protocol v2
Cellex’s qCOV assay is a viral enzyme activity assay, which detects the activity of coronaviral protease 3CL (chymotrypsin-like protease) in 15 minutes with sensitivity equivalent ...
Guidelines for antioxidant assays for food components
Guidelines for antioxidant assays for food components
AbstractRecently, research on antioxidants has become increasingly active in various fields. Antioxidants react through free radical or molecular oxygen quenching, being capable to...