Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Experimental Investigations of the Burning Behaviour of Transport Package Impact Limiters and of Fire Spread Impact Onto the Cask

View through CrossRef
Accident safe packages for the transport of spent nuclear fuel and high-level waste shall fulfil international IAEA safety requirements. Compliance is shown by consecutive mechanical and thermal testing. Additional numerical analysis are usually part of the safety evaluation. For damage protection some package designs are equipped with wood filled impact limiters encapsulated by steel sheets. The safety of these packages is established in compliance with IAEA regulations. Cumulative mechanical and fire tests are conducted to achieve safety standards and to prevent loss of containment. Mechanical reliability is proven by drop tests. Drop testing might cause significant damage of the impact limiter steel sheets and might enable sufficient oxygen supply to the impact limiter during the fire test to ignite the wood filling. The boundary conditions of the fire test are precisely described in the IAEA regulatory. During the test the impact limiter will be subjected to a 30 minute enduring fire phase. Subsequent to the fire phase any burning of the specimen has to extinguish naturally and no artificial cooling is allowed. At BAM a large-scale fire test with a real size impact limiter and a wood volume of about 3m3 was conducted to investigate the burning behaviour of wood filled impact limiters in steel sheet encapsulation. The impact limiter was equipped with extensive temperature monitoring equipment. Until today burning of such impact limiters is not sufficiently considered in transport package design and more investigation is necessary to explore the consequences of the impacting fire. The objective of the large scale test was to find out whether a self-sustaining smouldering or even a flaming fire inside the impact limiter was initiated and what impact on the cask is resulting. The amount of energy, transferred from the impact limiter into the cask is of particular importance for the safety of heavy weight packages. With the intention of heat flux quantification a new approach was made and a test bench was designed.
Title: Experimental Investigations of the Burning Behaviour of Transport Package Impact Limiters and of Fire Spread Impact Onto the Cask
Description:
Accident safe packages for the transport of spent nuclear fuel and high-level waste shall fulfil international IAEA safety requirements.
Compliance is shown by consecutive mechanical and thermal testing.
Additional numerical analysis are usually part of the safety evaluation.
For damage protection some package designs are equipped with wood filled impact limiters encapsulated by steel sheets.
The safety of these packages is established in compliance with IAEA regulations.
Cumulative mechanical and fire tests are conducted to achieve safety standards and to prevent loss of containment.
Mechanical reliability is proven by drop tests.
Drop testing might cause significant damage of the impact limiter steel sheets and might enable sufficient oxygen supply to the impact limiter during the fire test to ignite the wood filling.
The boundary conditions of the fire test are precisely described in the IAEA regulatory.
During the test the impact limiter will be subjected to a 30 minute enduring fire phase.
Subsequent to the fire phase any burning of the specimen has to extinguish naturally and no artificial cooling is allowed.
At BAM a large-scale fire test with a real size impact limiter and a wood volume of about 3m3 was conducted to investigate the burning behaviour of wood filled impact limiters in steel sheet encapsulation.
The impact limiter was equipped with extensive temperature monitoring equipment.
Until today burning of such impact limiters is not sufficiently considered in transport package design and more investigation is necessary to explore the consequences of the impacting fire.
The objective of the large scale test was to find out whether a self-sustaining smouldering or even a flaming fire inside the impact limiter was initiated and what impact on the cask is resulting.
The amount of energy, transferred from the impact limiter into the cask is of particular importance for the safety of heavy weight packages.
With the intention of heat flux quantification a new approach was made and a test bench was designed.

Related Results

Development of the Concrete Cask Horizontal Transfer System
Development of the Concrete Cask Horizontal Transfer System
Concrete cask system is focused as the candidate one for spent fuel dry storage facilities from economic potential in Japan. Concrete cask consists of a concrete storage cask and a...
Abstract 19049: CASK Regulates Sodium Channels Distribution and Function in Costameric Microdomain
Abstract 19049: CASK Regulates Sodium Channels Distribution and Function in Costameric Microdomain
Introduction: Proteins of the MAGUK family have emerged as key components in ion channels organization and regulation within specialized submembrane domains of cardiomy...
Behavior of Wood Filled Impact Limiters During the IAEA Thermal Test
Behavior of Wood Filled Impact Limiters During the IAEA Thermal Test
Packages for the transport of radioactive material are often equipped with impact limiters consisting of wood, encapsulated by steel sheets. These impact limiters shall ensure that...
PEMODELAN DINAMIK PENDINGINAN BAHAN BAKAR NUKLIR BEKAS REAKTOR RISET SECARA NATURAL KONVEKSI PADA PROTOTIPE DRY CASK STORAGE
PEMODELAN DINAMIK PENDINGINAN BAHAN BAKAR NUKLIR BEKAS REAKTOR RISET SECARA NATURAL KONVEKSI PADA PROTOTIPE DRY CASK STORAGE
PEMODELAN DINAMIK PENDINGINAN BAHAN BAKAR NUKLIR BEKAS REAKTOR RISET SECARA NATURAL KONVEKSI PADA PROTOTIPE DRY CASK STORAGE. Penelitian ini secara khusus bertujuan untuk menguji k...
Load-Limiters Effect on Occupant Restraint System Performance
Load-Limiters Effect on Occupant Restraint System Performance
<div class="section abstract"><div class="htmlview paragraph">This paper investigates the role that load-limiters play with respect to the performance of occupant prote...
Shielding Design for the <sup>99</sup>Mo Column Transport Cask
Shielding Design for the <sup>99</sup>Mo Column Transport Cask
The objective of this work is design a shielded cask to transport the radioactive 99Mo column from the radioisotopes facility to the consumers. The cask must be designed to confine...

Back to Top