Javascript must be enabled to continue!
Multiform Ventricular Ectopic Rhythm by Combined Parasystolic and Reentrant Activities
View through CrossRef
Multiform ventricular ectopic rhythm (MVER), i.e., at least two QRS configurations of ventricular ectopic beats (VEBs), was assessed by 24‐hour ambulatory ECG recording in four patients with ventricular parasystole (VP). In two of these four patients, VEBs with fixed coupling to the preceding impulses coexisted with VP beats of different configuration. In case no. 1, the VEBs had an identical coupling interval to sinus bents and VP beats, suggesting a mechanism of reentry elicited from both dominant pacemakers. In case no. 2, an intermittent form of VP due to type II second‐degree entrance block was present. In this patient, the VEBs were coupled to sinus beats and to sinus‐VP fusion beats and appeared to be dependent on the sinus beats reaching the VP focus. A mechanism of reentry determined by the penetration of sinus beats into the VP area, with prematurity‐dependent aberrancy of VEBs, was suggested for the coupled VEBs in this patient. These observations suggest that the coexistence of an automatic ventricular ectopic focus and of a reentrant activity determined by, or elicited from, an area of automaticity may constitute the underlying mechanism of MVER in some patients.
Title: Multiform Ventricular Ectopic Rhythm by Combined Parasystolic and Reentrant Activities
Description:
Multiform ventricular ectopic rhythm (MVER), i.
e.
, at least two QRS configurations of ventricular ectopic beats (VEBs), was assessed by 24‐hour ambulatory ECG recording in four patients with ventricular parasystole (VP).
In two of these four patients, VEBs with fixed coupling to the preceding impulses coexisted with VP beats of different configuration.
In case no.
1, the VEBs had an identical coupling interval to sinus bents and VP beats, suggesting a mechanism of reentry elicited from both dominant pacemakers.
In case no.
2, an intermittent form of VP due to type II second‐degree entrance block was present.
In this patient, the VEBs were coupled to sinus beats and to sinus‐VP fusion beats and appeared to be dependent on the sinus beats reaching the VP focus.
A mechanism of reentry determined by the penetration of sinus beats into the VP area, with prematurity‐dependent aberrancy of VEBs, was suggested for the coupled VEBs in this patient.
These observations suggest that the coexistence of an automatic ventricular ectopic focus and of a reentrant activity determined by, or elicited from, an area of automaticity may constitute the underlying mechanism of MVER in some patients.
Related Results
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Emerging Evidence of IgG4-Related Disease in Pericarditis: A Systematic Review
Abstract
Introduction
Immunoglobulin G4-related disease (IgG4-RD) is a recently identified immune-mediated condition that is debilitating and often overlooked. While IgG4-RD has be...
Assessment of Clinical Features Responsible for Ectopic Pregnancy
Assessment of Clinical Features Responsible for Ectopic Pregnancy
Background: Ectopic pregnancy is a lethal condition and a gynecological emergency. It is associated with maternal morbidity and mortality with pregnancy loss. The incidence of ecto...
Electrophysiological features of bioelectrical activity of the horse brain
Electrophysiological features of bioelectrical activity of the horse brain
Purpose: to study the bioelectrical activity of the brain and determine the parameters of electroencephalograms in sports and untrained horses.Materials and methods. The object of ...
Risk Factors and Patient Characteristics Associated with Ectopic Pregnancy
Risk Factors and Patient Characteristics Associated with Ectopic Pregnancy
Background: Ectopic pregnancy is an increasingly common gynecological emergency and a major cause of maternal morbidity in early pregnancy. Understanding the demographic and clinic...
Ectopic pregnancy after sequential embryo transfer: review of 22 cases
Ectopic pregnancy after sequential embryo transfer: review of 22 cases
To assess the prevalence of ectopic pregnancy among women who conceived with assisted reproductive technology and to see if there is increased risk after sequential embryo transfer...
Vagus nerve stimulation reduces ventricular arrhythmias and increases ventricular electrical stability
Vagus nerve stimulation reduces ventricular arrhythmias and increases ventricular electrical stability
AbstractBackgroundTranscutaneous stimulation of the auricular branch of the vagus nerve (AB‐VNS) is a potentially noninvasive, inexpensive, and safe approach for vagus nerve stimul...
Abstract 13023: Characteristics of Treatment Failure With Rate and Rhythm Control Strategies in Patients With Atrial Fibrillation: Insights From the AFFIRM (Atrial Fibrillation Follow-up Investigation of Rhythm Management) Trial
Abstract 13023: Characteristics of Treatment Failure With Rate and Rhythm Control Strategies in Patients With Atrial Fibrillation: Insights From the AFFIRM (Atrial Fibrillation Follow-up Investigation of Rhythm Management) Trial
Introduction:
In patients with atrial fibrillation (AF) both “rate control” and “rhythm control” therapies have distinct set of limitations. We sought to investigate th...
Abstract 11923: Ventricular Parasystole: An Under-Recognized Risk Factor for Ventricular Fibrillation in Patients With Implantable Cardioverter-Defibrillators
Abstract 11923: Ventricular Parasystole: An Under-Recognized Risk Factor for Ventricular Fibrillation in Patients With Implantable Cardioverter-Defibrillators
Introduction:
Ventricular parasystole is an uncommon characteristic of ventricular ectopic beats characterized by cyclical depolarization that is independent of the dom...

