Does Sagittal Alignment Matter? A Biomechanical Look at Pinning Pediatric Supracondylar Humerus Fractures
View through CrossRef
Objective:
Closed manipulation and percutaneous pinning is standard of care for displaced supracondylar humerus fractures, yet the optimal pin configuration, particularly in the sagittal plane, is not well defined. This study evaluates how sagittal plane pin variations affect construct strength biomechanically.
Methods:
One hundred synthetic pediatric humerus models were used to emulate supracondylar humerus fracture. The models were pinned using 4 different configurations uniformly divergent in the coronal plane with variations in the sagittal plane: (1) 2 diverging pins with the lateral pin anterior (n = 25), (2) 2 diverging pins with the lateral pin posterior (n = 25), (3) 2 parallel pins (n = 25), and (4) 3 parallel pins (n = 25). The models were tested under bending (flexion, extension, and varus) and rotational (internal and external) forces, measuring stiffness and torque. Statistical analyses identified significant differences across configurations.
Results:
The 2-pin parallel configuration (9.68 N/mm in extension, 8.76 N/mm in flexion, 0.14 N-m/deg in internal rotation, and 0.14 N-m/deg in external rotation) performed similarly to the 3-pin parallel setup (10.77 N/mm in extension, 7.78 N/mm in flexion, 0.16 N-m/deg in internal rotation, and 0.14 N-m/deg in external rotation), with no significant differences in stiffness. In contrast, both parallel configurations significantly outperformed the 2-pin anterior (5.22 N/mm in extension, 5.7 N/mm in flexion, 0.11 N-m/deg in internal rotation and 0.10 N-m/deg in external rotation) and posterior (9.86 N/mm in extension, 8.31 N/mm in flexion, 0.12N-m/deg in internal rotation, and 0.11 N-m/deg in external rotation) configurations in resisting deformation. No notable disparities were observed in varus loading among any configurations.
Conclusions:
This study illuminates the sagittal plane’s role in construct stability. It suggests that, when utilizing 2-pins, parallel configurations in the sagittal plane improve biomechanical stability. In addition, it suggests avoiding the lateral anterior pin configuration due to its biomechanical inferiority. Further research should assess ultimate strength and compare various 3-pin configurations to better delineate differences between 2-pin and 3-pin configurations regarding sagittal plane alignment.
Level of Evidence:
Level III—biomechanical study.
Ovid Technologies (Wolters Kluwer Health)
Title: Does Sagittal Alignment Matter? A Biomechanical Look at Pinning Pediatric Supracondylar Humerus Fractures
Description:
Objective:
Closed manipulation and percutaneous pinning is standard of care for displaced supracondylar humerus fractures, yet the optimal pin configuration, particularly in the sagittal plane, is not well defined.
This study evaluates how sagittal plane pin variations affect construct strength biomechanically.
Methods:
One hundred synthetic pediatric humerus models were used to emulate supracondylar humerus fracture.
The models were pinned using 4 different configurations uniformly divergent in the coronal plane with variations in the sagittal plane: (1) 2 diverging pins with the lateral pin anterior (n = 25), (2) 2 diverging pins with the lateral pin posterior (n = 25), (3) 2 parallel pins (n = 25), and (4) 3 parallel pins (n = 25).
The models were tested under bending (flexion, extension, and varus) and rotational (internal and external) forces, measuring stiffness and torque.
Statistical analyses identified significant differences across configurations.
Results:
The 2-pin parallel configuration (9.
68 N/mm in extension, 8.
76 N/mm in flexion, 0.
14 N-m/deg in internal rotation, and 0.
14 N-m/deg in external rotation) performed similarly to the 3-pin parallel setup (10.
77 N/mm in extension, 7.
78 N/mm in flexion, 0.
16 N-m/deg in internal rotation, and 0.
14 N-m/deg in external rotation), with no significant differences in stiffness.
In contrast, both parallel configurations significantly outperformed the 2-pin anterior (5.
22 N/mm in extension, 5.
7 N/mm in flexion, 0.
11 N-m/deg in internal rotation and 0.
10 N-m/deg in external rotation) and posterior (9.
86 N/mm in extension, 8.
31 N/mm in flexion, 0.
12N-m/deg in internal rotation, and 0.
11 N-m/deg in external rotation) configurations in resisting deformation.
No notable disparities were observed in varus loading among any configurations.
Conclusions:
This study illuminates the sagittal plane’s role in construct stability.
It suggests that, when utilizing 2-pins, parallel configurations in the sagittal plane improve biomechanical stability.
In addition, it suggests avoiding the lateral anterior pin configuration due to its biomechanical inferiority.
Further research should assess ultimate strength and compare various 3-pin configurations to better delineate differences between 2-pin and 3-pin configurations regarding sagittal plane alignment.
Level of Evidence:
Level III—biomechanical study.
Related Results
PROXIMAL HUMERUS FRACTURES, ANATOMY, EPIDEMIOLOGY, MECHANISMS OF ACTION, CLASSIFICATION, CLINICAL PRESENTATION, IMAGING PRESENTATION, DIFFERENTIAL DIAGNOSIS, TREATMENT AND COMPLICATIONS
PROXIMAL HUMERUS FRACTURES, ANATOMY, EPIDEMIOLOGY, MECHANISMS OF ACTION, CLASSIFICATION, CLINICAL PRESENTATION, IMAGING PRESENTATION, DIFFERENTIAL DIAGNOSIS, TREATMENT AND COMPLICATIONS
Introduction: Proximal humerus fractures (PHF) make up 5 to 6% of all fractures presented in adults. Approximately 67 to 85% of proximal humerus fractures are managed non-surgicall...
Increased pin diameter improves torsional stability in supracondylar humerus fractures: An experimental study
Increased pin diameter improves torsional stability in supracondylar humerus fractures: An experimental study
Background Pediatric supracondylar humerus fractures are the most common elbow fractures seen in children, and account for 16 % of all pediatric fractures. Closed reduction and per...
<b>Functional Outcome of Percutaneous Pining in Gartland Type III Supracondylar Humerus Fractures</b>
<b>Functional Outcome of Percutaneous Pining in Gartland Type III Supracondylar Humerus Fractures</b>
Background: Supracondylar fractures of the humerus are the most common pediatric elbow injuries, accounting for nearly two-thirds of cases, with Gartland type III representing the ...
COMPARISON OF TWO TECHNIQUES OF TREATING GARTLAND TYPE III SUPRACONDYLAR FRACTURE OF HUMERUS IN CHILDREN
COMPARISON OF TWO TECHNIQUES OF TREATING GARTLAND TYPE III SUPRACONDYLAR FRACTURE OF HUMERUS IN CHILDREN
Background: Supracondylar fractures of humerus are one of the largest sources of serious problems and treatment controversy in childhood fractures. The advantages and disadvantages...
A study on management of paediatric supracondylar humerus fractures with lateral percutaneous Kirschner wire fixation
A study on management of paediatric supracondylar humerus fractures with lateral percutaneous Kirschner wire fixation
<p class="abstract"><strong>Background:</strong> Supracondylar fracture of the humerus in children is a common injury encountered in orthopaedic practice. Undispl...
The Pediatric Anesthesiology Workforce: Projecting Supply and Trends 2015–2035
The Pediatric Anesthesiology Workforce: Projecting Supply and Trends 2015–2035
BACKGROUND:
A workforce analysis was conducted to predict whether the projected future supply of pediatric anesthesiologists is balanced with the requirements of the in...
The Geographic Distribution of Pediatric Anesthesiologists Relative to the US Pediatric Population
The Geographic Distribution of Pediatric Anesthesiologists Relative to the US Pediatric Population
BACKGROUND:
The geographic relationship between pediatric anesthesiologists and the pediatric population has potentially important clinical and policy implications. In ...
OUTCOME OF CROSSED K-WIRES WITH LATERAL K-WIRES FOR TYPE-III SUPRACONDYLAR FRACTURE OF HUMERUS IN CHILDREN
OUTCOME OF CROSSED K-WIRES WITH LATERAL K-WIRES FOR TYPE-III SUPRACONDYLAR FRACTURE OF HUMERUS IN CHILDREN
Background and Objectives: Elbow is the most common site of fractures in children. It accounts for approximately 60% of all injuries in children. These fractures are caused by dire...