The 6-m Timed Hop Is Not a Suitable Clinical Assessment Tool for Use Following Anterior Cruciate Ligament Reconstruction

View through CrossRef
Context: Single-leg hop tests are used to assess functional performance following anterior cruciate ligament (ACL) reconstruction. Recording 6-m timed hop scores using a stopwatch increases the potential for misclassification of patient status due to the number of error sources present. Objective: To examine the consistency of pass/fail (>90% limb symmetry index [LSI]) decisions in athletes tested at discharge following ACL reconstruction during the 6-m timed hop and the agreement between different human raters using a stopwatch and an electronic timing system. Setting: Clinic, rehabilitation. Participants: A total of 20 professional soccer players (age 24.6 [4.2] y; height 175.3 [10.2] cm; mass 73.6 [14.5] kg; 36 [10.5] wk following ACL reconstruction) volunteered to take part in this study. Main Outcome Measures: Two individual raters recorded each trial of the 6-m timed hop test on each limb with a stopwatch and an electronic timing system acted as the criterion measure. LSI scores were also computed with a pass score >90% LSI. Results: No significant differences were observed between limbs for any scoring method (P > .05). Mean differences indicated the electronic timing system was slower than both human raters (P < .05). Five participants failed the test (<90% LSI) but on each occasion this was only recorded by one method of rating. Kappa statistics showed no agreement in LSI scores across all 3 methods of scoring (κ = −.13) and no agreement when comparing the light gates to individual raters and rater 1 versus 2 (κ < 0). 95% limits of agreement in LSI scores recorded values of approximately ±20%. Conclusions: The 6-m timed hop test recorded using a stopwatch is not a valid measure to make clinical decisions following ACL reconstruction. Systematic bias between methods also suggests that a stopwatch and electronic timing system cannot be used interchangeably.
Title: The 6-m Timed Hop Is Not a Suitable Clinical Assessment Tool for Use Following Anterior Cruciate Ligament Reconstruction
Description:
Context: Single-leg hop tests are used to assess functional performance following anterior cruciate ligament (ACL) reconstruction.
Recording 6-m timed hop scores using a stopwatch increases the potential for misclassification of patient status due to the number of error sources present.
Objective: To examine the consistency of pass/fail (>90% limb symmetry index [LSI]) decisions in athletes tested at discharge following ACL reconstruction during the 6-m timed hop and the agreement between different human raters using a stopwatch and an electronic timing system.
Setting: Clinic, rehabilitation.
Participants: A total of 20 professional soccer players (age 24.
6 [4.
2] y; height 175.
3 [10.
2] cm; mass 73.
6 [14.
5] kg; 36 [10.
5] wk following ACL reconstruction) volunteered to take part in this study.
Main Outcome Measures: Two individual raters recorded each trial of the 6-m timed hop test on each limb with a stopwatch and an electronic timing system acted as the criterion measure.
LSI scores were also computed with a pass score >90% LSI.
Results: No significant differences were observed between limbs for any scoring method (P > .
05).
Mean differences indicated the electronic timing system was slower than both human raters (P < .
05).
Five participants failed the test (<90% LSI) but on each occasion this was only recorded by one method of rating.
Kappa statistics showed no agreement in LSI scores across all 3 methods of scoring (κ = −.
13) and no agreement when comparing the light gates to individual raters and rater 1 versus 2 (κ < 0).
95% limits of agreement in LSI scores recorded values of approximately ±20%.
Conclusions: The 6-m timed hop test recorded using a stopwatch is not a valid measure to make clinical decisions following ACL reconstruction.
Systematic bias between methods also suggests that a stopwatch and electronic timing system cannot be used interchangeably.

Related Results

Ứng dụng kỹ thuật BoBs để phát hiện một số bất thường nhiễm sắc thể trong chẩn đoán trước sinh
Ứng dụng kỹ thuật BoBs để phát hiện một số bất thường nhiễm sắc thể trong chẩn đoán trước sinh
Mục tiêu: Đánh giá giá trị kỹ thuật Bobs trong phát hiện một số lệch bội và mất đoạn nhỏ nhiễm sắc thể của thai. Đối tượng và phương pháp nghiên cứu: mẫu dịch ối của 1.880 thai phụ...
ANTERIOR CRUCIATE LIGAMENT, DESCRIPTION, RUPTURE AND TREATMENT
ANTERIOR CRUCIATE LIGAMENT, DESCRIPTION, RUPTURE AND TREATMENT
Introduction: the anterior cruciate ligament (ACL) along with the posterior cruciate ligament are the central stabilizers of the knee. Rupture of the ACL usually occurs in active a...
Physiotherapy treatment and rehabilitation following anterior cruciate ligament injury in New Zealand: Are we doing enough?
Physiotherapy treatment and rehabilitation following anterior cruciate ligament injury in New Zealand: Are we doing enough?
Physiotherapists are lead providers of rehabilitation following anterior cruciate ligament injury in New Zealand. Rehabilitation is considered an essential component following ante...
Mix En Meng It Op: Emile YX?'s Alternative Race and Language Politics in South African Hip-Hop
Mix En Meng It Op: Emile YX?'s Alternative Race and Language Politics in South African Hip-Hop
This paper explores South African hip-hop activist Emile YX?'s work to suggest that he presents an alternative take on mainstream US and South African hip-hop. While it is arguable...
Functional Evaluation of the Knee in Athletes and Sportsmen Undergoing Anterior Cruciate Ligament Reconstruction Surgery
Functional Evaluation of the Knee in Athletes and Sportsmen Undergoing Anterior Cruciate Ligament Reconstruction Surgery
The knee is a joint made up of bones, muscles, ligaments and cartilage. The anterior cruciate ligament is a fundamental part for the proper functioning of the knee, being responsib...
The Effects of Knee Reconstruction on Combined Anterior Cruciate Ligament and Anterolateral Capsular Deficiencies
The Effects of Knee Reconstruction on Combined Anterior Cruciate Ligament and Anterolateral Capsular Deficiencies
We tested the effect of intraarticular reconstructions of the anterior cruciate ligament alone and in combination with extraarticular reconstructions in 10 cadaveric knees. These k...
Anterior Cruciate Ligament: Anatomy and Biomechanics
Anterior Cruciate Ligament: Anatomy and Biomechanics
Abstract The Anterior cruciate ligament (ACL) is a unique structure and one of the most important ligaments for knee stability, serving as primary restriction for the anterior tibi...

Back to Top