Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Preprocedural Mean Platelet Volume Level Is a Predictor of In-Stent Restenosis of the Superficial Femoral Artery Stents in Follow-Up

View through CrossRef
Background. The mean platelet volume (MPV), the most commonly used measure of the platelet size, is a cheap and easy-to-use marker of the platelet activation. We aimed to evaluate the relationship between preprocedural MPV and other hematologic blood count parameters and in-stent restenosis in patients with superficial femoral artery (SFA) stenting.Methods and Results. The consecutive 118 patients who successfully underwent endovascular stenting of the SFA were enrolled retrospectively in the study. The mean follow-up was 23 ± 12 months. The in-stent restenosis was observed in 42 patients (35.6%). There were no statistically significant differences between the restenosis group and no-restenosis group in terms of age, gender, and smoking (p=0.116,p=0.924, andp=0.428, resp.). In the restenosis group, the MPV level was markedly higher than that in the no-restenosis group, and it was statistically significant (p<0.001). According to the ROC curve analysis, the optimal cutoff value of the MPV to determine the restenosis was >8.7 fL, and the level of the MPV >8.7 fL was a strong predictor of the restenosis (p<0.001) in logistic regression analysis.Conclusions. The measurement of the preprocedural MPV levels may help to identify high-risk patients for development of the in-stent restenosis. These patients may benefit from an aggresive antiplatelet therapy and close follow-up.
Title: Preprocedural Mean Platelet Volume Level Is a Predictor of In-Stent Restenosis of the Superficial Femoral Artery Stents in Follow-Up
Description:
Background.
The mean platelet volume (MPV), the most commonly used measure of the platelet size, is a cheap and easy-to-use marker of the platelet activation.
We aimed to evaluate the relationship between preprocedural MPV and other hematologic blood count parameters and in-stent restenosis in patients with superficial femoral artery (SFA) stenting.
Methods and Results.
The consecutive 118 patients who successfully underwent endovascular stenting of the SFA were enrolled retrospectively in the study.
The mean follow-up was 23 ± 12 months.
The in-stent restenosis was observed in 42 patients (35.
6%).
There were no statistically significant differences between the restenosis group and no-restenosis group in terms of age, gender, and smoking (p=0.
116,p=0.
924, andp=0.
428, resp.
).
In the restenosis group, the MPV level was markedly higher than that in the no-restenosis group, and it was statistically significant (p<0.
001).
According to the ROC curve analysis, the optimal cutoff value of the MPV to determine the restenosis was >8.
7 fL, and the level of the MPV >8.
7 fL was a strong predictor of the restenosis (p<0.
001) in logistic regression analysis.
Conclusions.
The measurement of the preprocedural MPV levels may help to identify high-risk patients for development of the in-stent restenosis.
These patients may benefit from an aggresive antiplatelet therapy and close follow-up.

Related Results

Predictors of insistent restenosis in patients undergoing percutaneous intervention
Predictors of insistent restenosis in patients undergoing percutaneous intervention
Coronary artery disease is one of the leading causes of morbidity and mortality worldwide. The first percutaneous coronary intervention was performed by Andreas Gruntzig on Septemb...
3D-printed polymeric bioresorbable stents for cardiovascular applications
3D-printed polymeric bioresorbable stents for cardiovascular applications
(English) Bioresorbable stents (BRS) have been envisioned as a revolution in the treatment of coronary heart disease. Ideally, stents would initially retain sufficient radial stren...
Novel functionalized and patterned surfaces for cardiovascular applications
Novel functionalized and patterned surfaces for cardiovascular applications
Nowadays, cardiovascular diseases are mainly treated by implantation of a metallic or polymeric mesh, called stent, which maintains the artery widely open. This technique shows ver...
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Abstract Introduction Coronary subclavian steal syndrome (CSSS) is a rare phenomenon that often goes undiagnosed and causes severe complications, including death. This report prese...
Incidence of Restenosis Following Rapamycin or Paclitaxeleluting Stent in Coronary Stent Implantation
Incidence of Restenosis Following Rapamycin or Paclitaxeleluting Stent in Coronary Stent Implantation
Background & Objectives: Coronary artery disease (CAD) is chiefly characterized by atherosclerosis and plaque formation in coronary arteries. The aim of this study was to evalu...
Six-Month Angiographic Outcome After Successful Repeat Percutaneous Intervention for In-Stent Restenosis
Six-Month Angiographic Outcome After Successful Repeat Percutaneous Intervention for In-Stent Restenosis
Background —In-stent restenosis is an increasing clinical problem. Discordant results have been published regarding the risk of recurrent restenosis after repeat angiop...