Javascript must be enabled to continue!
Development of bra pressure measuring system using air pressure sensor
View through CrossRef
Introduction: This paper is the result of the research “Development of bra pressure measuring system using air pressure sensor” developed in the Ha Noi University of Science and Technology in 2019.
Proplem: The pressure of the bra on the human body affects the comfort of the wearer and the wearer's health. Therefore, bra pressure is one of the most important parameters taken into account when designing and manufacturing bras.
Objective: To determine the pressure value of a bra, it is necessary to use a suitable pressure measuring device.
Methodology: The device operates on the principle of resitive gas pressure sensor, with 8 measuring channels. The system is controlled by the computer via programming software in the Visual C language, measuring the pressure of the shirt on the position on the curved surface of the human body. Pressure values and timed charts are displayed on the computer. The measuring device was tested with GE Druck DPI 610 pressure generator.
Results: Test results showed that the device has a sensitivity of 0.01 kPa, measuring range from 0.1to 10 kPa and an accuracy of 0.01 kPa.
Conclusion: This measurement system is important for objectively assessing the pressure of the bra on the wearer.
Originality: This paper presents the results of research and design of the PB228 system when measuring the pressure of the bra on the wearer's body in static, dynamic and static-dynamic combined states.
Limitations: The accuracy of the device only applies in standard conditions
Universidad Cooperativa de Colombia- UCC
Title: Development of bra pressure measuring system using air pressure sensor
Description:
Introduction: This paper is the result of the research “Development of bra pressure measuring system using air pressure sensor” developed in the Ha Noi University of Science and Technology in 2019.
Proplem: The pressure of the bra on the human body affects the comfort of the wearer and the wearer's health.
Therefore, bra pressure is one of the most important parameters taken into account when designing and manufacturing bras.
Objective: To determine the pressure value of a bra, it is necessary to use a suitable pressure measuring device.
Methodology: The device operates on the principle of resitive gas pressure sensor, with 8 measuring channels.
The system is controlled by the computer via programming software in the Visual C language, measuring the pressure of the shirt on the position on the curved surface of the human body.
Pressure values and timed charts are displayed on the computer.
The measuring device was tested with GE Druck DPI 610 pressure generator.
Results: Test results showed that the device has a sensitivity of 0.
01 kPa, measuring range from 0.
1to 10 kPa and an accuracy of 0.
01 kPa.
Conclusion: This measurement system is important for objectively assessing the pressure of the bra on the wearer.
Originality: This paper presents the results of research and design of the PB228 system when measuring the pressure of the bra on the wearer's body in static, dynamic and static-dynamic combined states.
Limitations: The accuracy of the device only applies in standard conditions.
Related Results
Parametric modelling & digital manufacturing for better bra fit
Parametric modelling & digital manufacturing for better bra fit
<p>This research focuses on developing an overall system for a more accurate bra design and fit. The bra, consequently, becomes part of a life-long service system that is abl...
Comparative Morphological Evaluation of Young Women’s Breast-Bra Reshaping by Different Bra Cups
Comparative Morphological Evaluation of Young Women’s Breast-Bra Reshaping by Different Bra Cups
Female breasts are regarded as a factor reflecting women’s morphological beauty. An appropriate bra can fulfill aesthetic needs, thus boosting self-esteem. This study proposed a me...
Sports Bra Pressure: Effect on Core Body Temperature and Comfort Sensation
Sports Bra Pressure: Effect on Core Body Temperature and Comfort Sensation
Background: Sports bras are engineer designed to enhance sports performance, which means that they need to provide an excellent fit, and offer adequate support and protection of th...
Dynamic stochastic modeling for inertial sensors
Dynamic stochastic modeling for inertial sensors
Es ampliamente conocido que los modelos de error para sensores inerciales tienen dos componentes: El primero es un componente determinista que normalmente es calibrado por el fabri...
Which Bra Components Contribute to Incorrect Bra Fit in Women Across a Range of Breast Sizes?
Which Bra Components Contribute to Incorrect Bra Fit in Women Across a Range of Breast Sizes?
The purpose of this study was to investigate whether different components of encapsulation-style bras contribute to incorrect bra fit among women and whether this was influenced by...
Abstract P4-13-15: A retrospective head-to-head comparison between TiLoop Bra/TiMesh and seragyn in 320 cases of reconstructive breast surgery
Abstract P4-13-15: A retrospective head-to-head comparison between TiLoop Bra/TiMesh and seragyn in 320 cases of reconstructive breast surgery
Abstract
Background: As an alternative option to ADMs (acellular dermal matrices) synthetic meshes are a cheaper and equally effective option in implanted breast rec...
Study on realizing the personalized customization of bra cup by solving the inverse problem of bra cup design
Study on realizing the personalized customization of bra cup by solving the inverse problem of bra cup design
In the process of bra cup customization, the matching between bra cup surface and breast shape largely depends on the practical experience of designers. To achieve effective custom...
The Triple Plane, the Bra-Flap, and the Inverted Bra-Flap Modified Dual Plane Techniques for Breast Augmentation
The Triple Plane, the Bra-Flap, and the Inverted Bra-Flap Modified Dual Plane Techniques for Breast Augmentation
Abstract
Background
Breast augmentation (BA) is a very common procedure performed for a wide range of indications. The short-ter...

