Javascript must be enabled to continue!
Alternative Level 1A to 1B Processing of GRACE Follow-On LRI data
View through CrossRef
<p>The Laser Ranging Interferometer (LRI) on-board GRACE Follow-On, which was&#160;launched in May 2018, provides ranging data between two satellites with previously unknown precision. The low noise level of approximately 200 pm/rtHz at Fourier frequencies around 10 Hz allows us to investigate features, that have not been seen before in the ranging data. &#160;</p><p>Due to this high sensitivity of the LRI, we are able to assess spurious linear non-gravitational accelerations in direction of the line-of-sight caused by attitude thruster activation, which should ideally produce only angular motion. This analysis may help to refine the models used in the Calibrated Accelerometer Data&#160;(ACT) product. The ACT product is derived from raw accelerometer data and corrects artefacts present in the raw accelerometer (ACC) product. However, linear non-gravitational accelerations can only be measured in narrow frequency ranges by the LRI, where&#160;the gravity ranging signal decayed below other contributors.</p><p>The conversion of LRI Level-1A to 1B is a complex task that comprises non-trivial removal of phase jumps, scaling, filtering and interpolation of data. In order to access the high-quality ranging data and have low post-fit residuals, the LRI instrument team at the Albert-Einstein Institute (AEI) in Hanover, Germany derived an alternative LRI Level-1B data product for January 2019 with some improvements compared to the official SDS RL04 data. The data can be downloaded at https://wolke7.aei.mpg.de/s/AYza4wrFjYBxHHQ.</p><p>In this poster we compare the AEI release with RL04 and explain the differences in the preprocessing of the data, which mainly originate from a more sophisticated estimation of the scale factor (i.e. the absolute laser frequency or wavelength), a continuous data stream without biases at day bounds and a light time correction with less noise from numerical inaccuracies.</p>
Title: Alternative Level 1A to 1B Processing of GRACE Follow-On LRI data
Description:
<p>The Laser Ranging Interferometer (LRI) on-board GRACE Follow-On, which was&#160;launched in May 2018, provides ranging data between two satellites with previously unknown precision.
The low noise level of approximately 200 pm/rtHz at Fourier frequencies around 10 Hz allows us to investigate features, that have not been seen before in the ranging data.
&#160;</p><p>Due to this high sensitivity of the LRI, we are able to assess spurious linear non-gravitational accelerations in direction of the line-of-sight caused by attitude thruster activation, which should ideally produce only angular motion.
This analysis may help to refine the models used in the Calibrated Accelerometer Data&#160;(ACT) product.
The ACT product is derived from raw accelerometer data and corrects artefacts present in the raw accelerometer (ACC) product.
However, linear non-gravitational accelerations can only be measured in narrow frequency ranges by the LRI, where&#160;the gravity ranging signal decayed below other contributors.
</p><p>The conversion of LRI Level-1A to 1B is a complex task that comprises non-trivial removal of phase jumps, scaling, filtering and interpolation of data.
In order to access the high-quality ranging data and have low post-fit residuals, the LRI instrument team at the Albert-Einstein Institute (AEI) in Hanover, Germany derived an alternative LRI Level-1B data product for January 2019 with some improvements compared to the official SDS RL04 data.
The data can be downloaded at https://wolke7.
aei.
mpg.
de/s/AYza4wrFjYBxHHQ.
</p><p>In this poster we compare the AEI release with RL04 and explain the differences in the preprocessing of the data, which mainly originate from a more sophisticated estimation of the scale factor (i.
e.
the absolute laser frequency or wavelength), a continuous data stream without biases at day bounds and a light time correction with less noise from numerical inaccuracies.
</p>.
Related Results
Thermal Influence on the LRI Scale Factor
Thermal Influence on the LRI Scale Factor
<p>In this talk we present the current status of our investigations regarding variations of the LRI scale factor with spotlight on the thermal environment of the LRI....
Relative Kinematic Orbit Determination for GRACE-FO Satellite by Jointing GPS and LRI
Relative Kinematic Orbit Determination for GRACE-FO Satellite by Jointing GPS and LRI
As the first in-orbit formation satellites equipped with a Laser Ranging Interferometer (LRI) instrument, Gravity Recovery and Climate Experiment Follow-on (GRACE-FO) satellites ar...
Novel LRI Level 0/1A Data Simulator
Novel LRI Level 0/1A Data Simulator
GRACE-FO was launched almost six years ago, following the successful GRACE mission. Measuring changes in the Earth's mass distribution is useful for climate research, such as monit...
Scale Factor Determination for the GRACE-FO LRI and Thermal Coupling in KBR-LRI Residuals
Scale Factor Determination for the GRACE-FO LRI and Thermal Coupling in KBR-LRI Residuals
<p>The GRACE-FO missions hosts two ranging instruments, namely the prime K-Band Ranging (KBR) and the Laser Ranging Interferometer (LRI) as a technology demonstrator....
Optical Cavity Developments for GRACE-like Architectures
Optical Cavity Developments for GRACE-like Architectures
The Laser Ranging Interferometer (LRI) on GRACE FO provided orders of magnitude improved precision satellite-to-satellite ranging measurements over the microwave ranging instrument...
Contribution Analysis of the Addition of Laser Ranging Interferometry on GRACE-FO Gravity Field Estimation under Different Accelerometer Calibration Schemes
Contribution Analysis of the Addition of Laser Ranging Interferometry on GRACE-FO Gravity Field Estimation under Different Accelerometer Calibration Schemes
To investigate the influence of K-Band microwave ranging (KBR) and Laser Ranging Interferometer (LRI) inter-satellite range-rates from the GRACE-FO mission on the recovery of gravi...
Temporal Patterns, Causes, and Risk Determinants of Lower Respiratory Infections in BRICS+ Countries: A Longitudinal Inter-Country Assessment of Disease Burdens
Temporal Patterns, Causes, and Risk Determinants of Lower Respiratory Infections in BRICS+ Countries: A Longitudinal Inter-Country Assessment of Disease Burdens
Abstract
With the inclusion of new member states, nearly half of the world's population today residence in the BRICS + countries. However, no studies have systematically as...
Patterns in GRACE-FO LRI Post-Fit Range Rate Residuals
Patterns in GRACE-FO LRI Post-Fit Range Rate Residuals
The LRI on GRACE Follow-On (GRACE-FO) provided range and range rate measurements for more than 4 years. At our institute we produce monthly gravity field coefficients from these ob...

