Noncontact 3D evaluation of surface topography of reciprocating instruments after retreatment procedures
View through CrossRef
Abstract This study evaluated the Reciproc R25 and Pro-R 25 instruments in unused condition, after one and a second use in endodontic retreatment employing a noncontact 3D light interferometer profiler, scanning electron microscopy (SEM) and cyclic fatigue tests. Twenty single-root teeth were instrumented with Reciproc R25 and filled with gutta-percha and sealer. A 3D profiler with a 20x objective using the Mx™ software was used to evaluate the cutting blade surfaces of Reciproc R25 and Pro-R 25 (n=5 per group) in unused condition, after the first and second uses in retreatment procedures. After retreatment, SEM was used to evaluate the topographic features of the used instruments. Cyclic fatigue tests were performed to compare new to used instruments. One-way ANOVA followed by Tukey test was used to compare the tested instruments before and after the first and second uses. Student t-test was used to compare the different instruments and for cyclic fatigue evaluation. No significant differences were observed in the cutting blade surfaces of Reciproc and Pro-R before and after one and two uses (p>0.05). Reciproc without use showed higher Sa and Sq when compared to Pro-R without use (p<0.05). No differences were observed between Reciproc and Pro-R after one and two uses (p>0.05). New and unused Reciproc showed longer time to fracture than Pro-R instruments (p<0.05), and only Pro-R showed differences between new and used instruments (p<0.05). Retreatment procedures with Reciproc and Pro-R did not change the surface topography of instruments. Reciproc had greater resistance to cyclic fatigue compared with Pro-R.
Title: Noncontact 3D evaluation of surface topography of reciprocating instruments after retreatment procedures
Description:
Abstract This study evaluated the Reciproc R25 and Pro-R 25 instruments in unused condition, after one and a second use in endodontic retreatment employing a noncontact 3D light interferometer profiler, scanning electron microscopy (SEM) and cyclic fatigue tests.
Twenty single-root teeth were instrumented with Reciproc R25 and filled with gutta-percha and sealer.
A 3D profiler with a 20x objective using the Mx™ software was used to evaluate the cutting blade surfaces of Reciproc R25 and Pro-R 25 (n=5 per group) in unused condition, after the first and second uses in retreatment procedures.
After retreatment, SEM was used to evaluate the topographic features of the used instruments.
Cyclic fatigue tests were performed to compare new to used instruments.
One-way ANOVA followed by Tukey test was used to compare the tested instruments before and after the first and second uses.
Student t-test was used to compare the different instruments and for cyclic fatigue evaluation.
No significant differences were observed in the cutting blade surfaces of Reciproc and Pro-R before and after one and two uses (p>0.
05).
Reciproc without use showed higher Sa and Sq when compared to Pro-R without use (p<0.
05).
No differences were observed between Reciproc and Pro-R after one and two uses (p>0.
05).
New and unused Reciproc showed longer time to fracture than Pro-R instruments (p<0.
05), and only Pro-R showed differences between new and used instruments (p<0.
05).
Retreatment procedures with Reciproc and Pro-R did not change the surface topography of instruments.
Reciproc had greater resistance to cyclic fatigue compared with Pro-R.
Related Results
Cost‐effectiveness analysis of full versus selective root canal retreatment
Cost‐effectiveness analysis of full versus selective root canal retreatment
AbstractAimSelective root‐canal retreatment has been proposed as an alternative to full retreatment in multirooted, root‐canal‐filled teeth with evidence of apical pathology, where...
Verification of remaining filling materials in flattened/oval-shaped root canals after use of several endodontic retreatment protocols
Verification of remaining filling materials in flattened/oval-shaped root canals after use of several endodontic retreatment protocols
This study verified of remaining filling materials in flattened/oval-shaped root canals after use of several endodontic retreatment protocols. Material and methods: Seventy human m...
The importance of radiological follow-up and relevant interventions for aneurysmal recurrence after endovascular treatment
The importance of radiological follow-up and relevant interventions for aneurysmal recurrence after endovascular treatment
Background:
Recurrence after cerebral aneurysm treatment is an important problem. Cerebrovascular endovascular treatment has a higher recurrence and retreatment...
Does selective root canal retreatment preserve the tooth’s fracture resistance? An ex-vivo study
Does selective root canal retreatment preserve the tooth’s fracture resistance? An ex-vivo study
Abstract
Objectives
To assess the tooth’s fracture resistance when submitted to a selective root canal retreatment compared to the conventional appr...
Evaluation of Effectiveness of Two Different Retreatment Systems in Removal of Obturation Materials From Curved Canals: An in-Vitro Study
Evaluation of Effectiveness of Two Different Retreatment Systems in Removal of Obturation Materials From Curved Canals: An in-Vitro Study
Abstract
Introduction:
The primary objective of endodontic retreatment is to remove the contamination of the root canals, thus ...
Cleaning Efficacy, Debris Extrusion, and Instrument Separation during Root Canal Filling Removal using Continuous Rotation, Reciprocation, and Optimum Torque Reverse Motions: An In Vitro Study
Cleaning Efficacy, Debris Extrusion, and Instrument Separation during Root Canal Filling Removal using Continuous Rotation, Reciprocation, and Optimum Torque Reverse Motions: An In Vitro Study
Abstract
This study aims to address the Optimum Torque Reverse (OTR) efficacy in root canal obturationmaterials removal, the amount of apically extruded debris, a...
Comparative evaluations on the canal-centering ability of novel heat-treated retreatment file system using nano-computed tomography
Comparative evaluations on the canal-centering ability of novel heat-treated retreatment file system using nano-computed tomography
Abstract
Introduction:
The main goal of instrumentation during retreatment is to maintain the original curvature of the canal during retrieval of...
Evaluation of Obturating Material Removal from Root Canal by Hedstrom and Rotary Retreatment File
Evaluation of Obturating Material Removal from Root Canal by Hedstrom and Rotary Retreatment File
An in vitro investigation was conducted to assess the efficacy of Hedstrom and Rotary Retreatment File using Cone Beam Computed Tomography (CBCT) in removing obturating material fr...