Javascript must be enabled to continue!
A Wearable Gait Phase Detection System Based on Force Myography Techniques
View through CrossRef
(1) Background: Quantitative evaluation of gait parameters can provide useful information for constructing individuals’ gait profile, diagnosing gait abnormalities, and better planning of rehabilitation schemes to restore normal gait pattern. Objective determination of gait phases in a gait cycle is a key requirement in gait analysis applications; (2) Methods: In this study, the feasibility of using a force myography-based technique for a wearable gait phase detection system is explored. In this regard, a force myography band is developed and tested with nine participants walking on a treadmill. The collected force myography data are first examined sample-by-sample and classified into four phases using Linear Discriminant Analysis. The gait phase events are then detected from these classified samples using a set of supervisory rules; (3) Results: The results show that the force myography band can correctly detect more than 99.9% of gait phases with zero insertions and only four deletions over 12,965 gait phase segments. The average temporal error of gait phase detection is 55.2 ms, which translates into 2.1% error with respect to the corresponding labelled stride duration; (4) Conclusions: This proof-of-concept study demonstrates the feasibility of force myography techniques as viable solutions in developing wearable gait phase detection systems.
Title: A Wearable Gait Phase Detection System Based on Force Myography Techniques
Description:
(1) Background: Quantitative evaluation of gait parameters can provide useful information for constructing individuals’ gait profile, diagnosing gait abnormalities, and better planning of rehabilitation schemes to restore normal gait pattern.
Objective determination of gait phases in a gait cycle is a key requirement in gait analysis applications; (2) Methods: In this study, the feasibility of using a force myography-based technique for a wearable gait phase detection system is explored.
In this regard, a force myography band is developed and tested with nine participants walking on a treadmill.
The collected force myography data are first examined sample-by-sample and classified into four phases using Linear Discriminant Analysis.
The gait phase events are then detected from these classified samples using a set of supervisory rules; (3) Results: The results show that the force myography band can correctly detect more than 99.
9% of gait phases with zero insertions and only four deletions over 12,965 gait phase segments.
The average temporal error of gait phase detection is 55.
2 ms, which translates into 2.
1% error with respect to the corresponding labelled stride duration; (4) Conclusions: This proof-of-concept study demonstrates the feasibility of force myography techniques as viable solutions in developing wearable gait phase detection systems.
Related Results
Making Sense of Sensor Data
Making Sense of Sensor Data
Every year, approximately 12.2 million people worldwide experience a stroke, placing a significant burden on individuals, families, and healthcare systems. Despite rehabilitation, ...
<b>Predictive Use of Wearable Sensors for Detecting Gait Deterioration in Children with Cerebral Palsy: A Narrative Review</b>
<b>Predictive Use of Wearable Sensors for Detecting Gait Deterioration in Children with Cerebral Palsy: A Narrative Review</b>
Background: Wearable sensor technologies are increasingly used to quantify gait in children with cerebral palsy (CP) outside laboratory settings, with potential to support earlier ...
Gait assessments in patients with early Parkinson's disease
Gait assessments in patients with early Parkinson's disease
Introduction : Gait disturbances are affected in all stages of PD. At the early stages of the disease, gait disturbances can be present but in most patients, it does not cause sign...
Validity of self-reporting of gait alteration after tap test among patients with idiopathic normal pressure hydrocephalus
Validity of self-reporting of gait alteration after tap test among patients with idiopathic normal pressure hydrocephalus
PurposeThe study aimed to examine the validity of self-reporting as an additional method to indicate gait alteration among patients with idiopathic normal pressure hydrocephalus. T...
Gait Training Techniques in Children
Gait Training Techniques in Children
The development of gait is a fundamental milestone in childhood that signifies the onset of functional independence, social engagement, and cognitive exploration. The book “Gait Tr...
Dynamic Gait Parameters in Patients With Nonunion of the Tibia Following Treatment With the Ilizarov Method
Dynamic Gait Parameters in Patients With Nonunion of the Tibia Following Treatment With the Ilizarov Method
Abstract
The purpose of this study was a comprehensive assessment of the dynamic parameters of gait in patients who underwent Ilizarov treatment for nonunion of the ...
Distinct roles of the human cuneiform and pedunculopontine nuclei in gait and freezing of gait
Distinct roles of the human cuneiform and pedunculopontine nuclei in gait and freezing of gait
Abstract
Freezing of gait (FOG) in Parkinson’s disease (PD) is a major cause of disability, often resistant to dopaminergic therapy and deep brain stimulation (DB...
MMF-Gait: A Multi-Model Fusion-Enhanced Gait Recognition Framework Integrating Convolutional and Attention Networks
MMF-Gait: A Multi-Model Fusion-Enhanced Gait Recognition Framework Integrating Convolutional and Attention Networks
Gait recognition is a reliable biometric approach that uniquely identifies individuals based on their natural walking patterns. It is widely used to recognize individuals who are c...

