Javascript must be enabled to continue!
WITHDRAWN: The enhancement of energetic and exergetic performance of embedded twisted rib turbulator over absorber plate of solar air heater
View through CrossRef
Abstract
Owing to present investigation, a stochastic analysis is conducted to numerically optimize the energetic and exergetic efficiencies of embedded twisted rib turbulator over absorber plate of solar air heaters (SAHs). These efficiencies are assessed taking into account temperature rise and design characteristics. The criterion in context to energy efficiency do not take into consideration the pumping force which is needed to blow the air from the duct. Therefore, estimating the energy distribution of solar air heaters becomes a difficult task when evaluating their exergetic or effective efficiency. The experimental work determined the Nu and fr correlations in the term of geometrical configurations which are considered for evaluating the thermal behavior and compared to prior findings with smooth plate. The Optimal turbulator parameters were defined by the exergetic efficiency criterion in terms of the Reynolds and insolation.
Maximum improvements in energetic and exergetic efficiencies were reported as
η
th
=1.81;
η
eff
=1.79 and
η
II
=1.82 times over smooth plate for a geometric arrangement with P/e = 8, α = 60°, y/e = 3 and Re = 5000. The maximum differences between simulated and experimental results, when taken into account, resulted ± 6%. The current methodology also tackles the methods to research novel artificial turbulator to increase the energetic and exergetic performance of a SAHs, making it feasible to develop a design plot for the turbulator parameter without having to spend a lot of money on actual trials.
Springer Science and Business Media LLC
Title: WITHDRAWN: The enhancement of energetic and exergetic performance of embedded twisted rib turbulator over absorber plate of solar air heater
Description:
Abstract
Owing to present investigation, a stochastic analysis is conducted to numerically optimize the energetic and exergetic efficiencies of embedded twisted rib turbulator over absorber plate of solar air heaters (SAHs).
These efficiencies are assessed taking into account temperature rise and design characteristics.
The criterion in context to energy efficiency do not take into consideration the pumping force which is needed to blow the air from the duct.
Therefore, estimating the energy distribution of solar air heaters becomes a difficult task when evaluating their exergetic or effective efficiency.
The experimental work determined the Nu and fr correlations in the term of geometrical configurations which are considered for evaluating the thermal behavior and compared to prior findings with smooth plate.
The Optimal turbulator parameters were defined by the exergetic efficiency criterion in terms of the Reynolds and insolation.
Maximum improvements in energetic and exergetic efficiencies were reported as
η
th
=1.
81;
η
eff
=1.
79 and
η
II
=1.
82 times over smooth plate for a geometric arrangement with P/e = 8, α = 60°, y/e = 3 and Re = 5000.
The maximum differences between simulated and experimental results, when taken into account, resulted ± 6%.
The current methodology also tackles the methods to research novel artificial turbulator to increase the energetic and exergetic performance of a SAHs, making it feasible to develop a design plot for the turbulator parameter without having to spend a lot of money on actual trials.
Related Results
Are Cervical Ribs Indicators of Childhood Cancer? A Narrative Review
Are Cervical Ribs Indicators of Childhood Cancer? A Narrative Review
Abstract
A cervical rib (CR), also known as a supernumerary or extra rib, is an additional rib that forms above the first rib, resulting from the overgrowth of the transverse proce...
Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract
Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review
FAKTOR-FAKTOR YANG MEMPENGARUHI MORTALITAS PADA PASIEN DENGAN FRAKTUR COSTA: Literature Review Anna Tri Wahyuni1), Masfuri2), Liya Arista3)1,2,3 Fakultas Ilmu Keperawatan Univers...
Far Posterior Approach for Rib Fracture Fixation
Far Posterior Approach for Rib Fracture Fixation
Background:
The present video article describes the far posterior or paraspinal approach to posterior rib fractures. This approach is utilized to optimize visualization...
Thermal and Thermo-hydraulic Performance of Packed Bed Solar Air Heater
Thermal and Thermo-hydraulic Performance of Packed Bed Solar Air Heater
Modification of flow passage of air in a solar air heater using a packing material is one of available techniques to considerably improve thermal performance of solar air heaters. ...
Heat transfer enhancement of a solar air heater using capsule-shaped turbulators: a numerical analysis
Heat transfer enhancement of a solar air heater using capsule-shaped turbulators: a numerical analysis
Abstract
The development of a laminar sublayer inside the channel of the solar collector results in a poor heat transfer coefficient. Adding artificial roughness to the a...
A Review on Heat Transfer Enhancement of Solar Air Heater Using Various Artificial Roughed Geometries
A Review on Heat Transfer Enhancement of Solar Air Heater Using Various Artificial Roughed Geometries
Solar air heater acts as one of the important components in utilization of solar energy. The air heater absorbs the irradiance and converts it into heat energy at the absorbing sur...
[RETRACTED] Gro-X Male Enhancement | Safely Grow Your Size, Sex Drive v1
[RETRACTED] Gro-X Male Enhancement | Safely Grow Your Size, Sex Drive v1
[RETRACTED]Gro-X Male Enhancement Reviews - Is It Worth the Money? Scam or Legit? Gro-X Male Enhancement Male health is very important, especially for a couple. Low sperm count an...

