Manufacturing, installation, commissioning, and first results with the 3D low-temperature co-fired ceramic high-frequency magnetic sensors on the Tokamak à Configuration Variable

View through CrossRef
Innovative high-frequency magnetic sensors have been designed and manufactured in-house for installation on the Tokamak à Configuration Variable (TCV), which are now routinely operational during the TCV experimental campaigns. These sensors combine the Low Temperature Co-fired Ceramic (LTCC) and the classical thick-film technologies and are in various aspects similar to the majority of the in-vessel inductive magnetic sensors foreseen for ITER (around 450 out of the 505 currently being procured are of the LTCC-1D type). The TCV LTCC-3D magnetic sensors provide measurements in the frequency range up to 1 MHz of the perturbations to the wall-aligned toroidal (δBTOR), vertical (δBVER), and radial (δBRAD) magnetic field components. Knowledge of the equilibrium at the last closed flux-surface allows us to then obtain the field-aligned parallel (δBPAR ∼ δBTOR), poloidal (δBPOL), and normal (δBNOR) components, the latter being in most cases rather different from the vertical and radial components, respectively. The main design principles were aimed at increasing the effective area and reducing the self-inductance of the sensor in each of the three measurement axes, which are centered at the same position on each sensor, while reducing the mutual and parasitic coupling between them by optimizing the on-board wiring. The physics requirements are set by the installation of two high-power/high-energy neutral beam injection systems on TCV, i.e., studying fast ions physics, coherent instabilities, and turbulence in the (super-)Alfvénic frequency range. In this paper, we report the manufacturing, installation, and commissioning work for these high-frequency LTCC-3D magnetic sensors and conclude with an overview of illustrative experimental results obtained with this system. The LTCC-3D data provide new insights into the δBPOL coherent (eigenmodes, up to ∼400 kHz) and in-coherent background turbulent fluctuations in the higher frequency range up to ∼1 MHz, which were not previously available with the TCV Mirnov sensors. Furthermore, the LTCC-3D δBPOL measurements allow us to cross-check the data obtained with the standard Mirnov coils and have led to the identification of largeelectromagnetic (EM) noise pick-up for the Mirnov data acquisition (DAQ). When the sources of EM noise pick-up on the Mirnov DAQ are removed, the LTCC-3D data for δBPOL are in good overall agreement, i.e., within the expected measurement uncertainties, with those obtained with the standard Mirnov sensors located at the same poloidal position in the frequency range where the respective data acquisition overlap, routinely up to 125 kHz and up to 250 kHz in some discharges. The LTCC-3D δBPAR measurements (not previously available in TCV or elsewhere) provide evidence that certain instabilities have a finite parallel δB at the wall, hence at the LCFS, consistent with the recent theoretical results for pressure-driven modes. The LTCC-3D δBNOR measurements improve significantly on the corresponding measurements with the saddle loops, which are mounted onto the wall and have a bandwidth of ∼3 kHz (due to the wall penetration time). A detailed end-to-end system modeling tool has been developed and applied to test on the simulated data the actual measurement capabilities of this new diagnostic system and obtain the ensuing estimates of the intrinsic measurement uncertainties. A detailed error analysis is then performed so that, finally, fully calibrated, absolute measurements of the frequency-dependent amplitude and spectral breaks of coherent eigenmodes and in-coherent broadband magnetic fluctuations are provided for the first time in physical units with quantitative uncertainties.
Title: Manufacturing, installation, commissioning, and first results with the 3D low-temperature co-fired ceramic high-frequency magnetic sensors on the Tokamak à Configuration Variable
Description:
Innovative high-frequency magnetic sensors have been designed and manufactured in-house for installation on the Tokamak à Configuration Variable (TCV), which are now routinely operational during the TCV experimental campaigns.
These sensors combine the Low Temperature Co-fired Ceramic (LTCC) and the classical thick-film technologies and are in various aspects similar to the majority of the in-vessel inductive magnetic sensors foreseen for ITER (around 450 out of the 505 currently being procured are of the LTCC-1D type).
The TCV LTCC-3D magnetic sensors provide measurements in the frequency range up to 1 MHz of the perturbations to the wall-aligned toroidal (δBTOR), vertical (δBVER), and radial (δBRAD) magnetic field components.
Knowledge of the equilibrium at the last closed flux-surface allows us to then obtain the field-aligned parallel (δBPAR ∼ δBTOR), poloidal (δBPOL), and normal (δBNOR) components, the latter being in most cases rather different from the vertical and radial components, respectively.
The main design principles were aimed at increasing the effective area and reducing the self-inductance of the sensor in each of the three measurement axes, which are centered at the same position on each sensor, while reducing the mutual and parasitic coupling between them by optimizing the on-board wiring.
The physics requirements are set by the installation of two high-power/high-energy neutral beam injection systems on TCV, i.
e.
, studying fast ions physics, coherent instabilities, and turbulence in the (super-)Alfvénic frequency range.
In this paper, we report the manufacturing, installation, and commissioning work for these high-frequency LTCC-3D magnetic sensors and conclude with an overview of illustrative experimental results obtained with this system.
The LTCC-3D data provide new insights into the δBPOL coherent (eigenmodes, up to ∼400 kHz) and in-coherent background turbulent fluctuations in the higher frequency range up to ∼1 MHz, which were not previously available with the TCV Mirnov sensors.
Furthermore, the LTCC-3D δBPOL measurements allow us to cross-check the data obtained with the standard Mirnov coils and have led to the identification of largeelectromagnetic (EM) noise pick-up for the Mirnov data acquisition (DAQ).
When the sources of EM noise pick-up on the Mirnov DAQ are removed, the LTCC-3D data for δBPOL are in good overall agreement, i.
e.
, within the expected measurement uncertainties, with those obtained with the standard Mirnov sensors located at the same poloidal position in the frequency range where the respective data acquisition overlap, routinely up to 125 kHz and up to 250 kHz in some discharges.
The LTCC-3D δBPAR measurements (not previously available in TCV or elsewhere) provide evidence that certain instabilities have a finite parallel δB at the wall, hence at the LCFS, consistent with the recent theoretical results for pressure-driven modes.
The LTCC-3D δBNOR measurements improve significantly on the corresponding measurements with the saddle loops, which are mounted onto the wall and have a bandwidth of ∼3 kHz (due to the wall penetration time).
A detailed end-to-end system modeling tool has been developed and applied to test on the simulated data the actual measurement capabilities of this new diagnostic system and obtain the ensuing estimates of the intrinsic measurement uncertainties.
A detailed error analysis is then performed so that, finally, fully calibrated, absolute measurements of the frequency-dependent amplitude and spectral breaks of coherent eigenmodes and in-coherent broadband magnetic fluctuations are provided for the first time in physical units with quantitative uncertainties.

Related Results

Integrated commissioning for integrated care
Integrated commissioning for integrated care
Background: To support the success of integrated care, it must be underpinned by integrated commissioning. This workshop introduces the Integrated System Commissioning Program, dra...
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
Analysis of energetic particle-driven Alfvénic instabilities in tokamak and stellarator plasmas using three dimensional numerical tools
Analysis of energetic particle-driven Alfvénic instabilities in tokamak and stellarator plasmas using three dimensional numerical tools
In this thesis, a detailed analysis of the experientially observed energetic particle-driven Alfvénic instabilities in tokamak and stellarator plasmas using three dimensional numer...
Analysis of commissioning and procurement of adult social care in Scotland
Analysis of commissioning and procurement of adult social care in Scotland
Background: Strategic planning and commissioning of adult social care (ASC) involves forecasting population needs across a defined area, together with availability of services or r...
The West Point Band's Wind Commissioning Project in Celebration of the Bicentennial of the United States Military Academy
The West Point Band's Wind Commissioning Project in Celebration of the Bicentennial of the United States Military Academy
The United States Military Academy Band, also known as the West Point Band is the oldest active band in the United States Army and the oldest unit at the United States Military Aca...
TU‐G‐116‐01: A Roadmap for Installing and Commissioning New Equipment
TU‐G‐116‐01: A Roadmap for Installing and Commissioning New Equipment
Learning Objectives:1. To learn how to build a new equipment commissioning project plan using efficient project management methods2. To identify equipment, personnel resources and ...
Magnetic cloak made of NdFeB permanent magnetic material
Magnetic cloak made of NdFeB permanent magnetic material
In the past few years, the concept of an electromagnetic invisibility cloak has received much attention. Based on the pioneering theoretical work, invisibility cloaks have been gre...

Back to Top