Javascript must be enabled to continue!
A lanthanum bromide detector of runaway electrons for TCV
View through CrossRef
The safe control and dissipation of Runaway Electrons (REs) generated in tokamak plasmas is vital for the operation of future fusion reactors. Measuring the evolution of RE energy in tokamaks is important for understanding their generation, transport, and termination. A new gamma ray spectrometer using a 2″ × 2″ cylindrical, cerium doped lanthanum bromide (LaBr3:Ce) scintillator coupled to a fast photomultiplier tube was developed for studying runaway electrons on the Tokamak à Configuration Variable (TCV). This diagnostic is capable of measuring the RE bremsstrahlung energy spectrum between 1 and 20 MeV with a peak height resolution of 1.91% at 1.44 MeV. A calibration of the detector using its self-emission up to 2.66 MeV was performed and modeled using Geant4. This model was then applied to predict the detector response to photons originating from TCV. The diagnostic was employed to measure the high energy Hard X-Ray (HXR) spectrum with energies in the range from 0.5 MeV to ∼8MeV on TCV for the first time. In TCV, the observations made with this system are demonstrated to provide insights into the change in RE energies during current ramps.
Title: A lanthanum bromide detector of runaway electrons for TCV
Description:
The safe control and dissipation of Runaway Electrons (REs) generated in tokamak plasmas is vital for the operation of future fusion reactors.
Measuring the evolution of RE energy in tokamaks is important for understanding their generation, transport, and termination.
A new gamma ray spectrometer using a 2″ × 2″ cylindrical, cerium doped lanthanum bromide (LaBr3:Ce) scintillator coupled to a fast photomultiplier tube was developed for studying runaway electrons on the Tokamak à Configuration Variable (TCV).
This diagnostic is capable of measuring the RE bremsstrahlung energy spectrum between 1 and 20 MeV with a peak height resolution of 1.
91% at 1.
44 MeV.
A calibration of the detector using its self-emission up to 2.
66 MeV was performed and modeled using Geant4.
This model was then applied to predict the detector response to photons originating from TCV.
The diagnostic was employed to measure the high energy Hard X-Ray (HXR) spectrum with energies in the range from 0.
5 MeV to ∼8MeV on TCV for the first time.
In TCV, the observations made with this system are demonstrated to provide insights into the change in RE energies during current ramps.
Related Results
Determination of Lanthanum in Lanthanum Dioxycarbonate Drug Substance by Potentiometric Titration
Determination of Lanthanum in Lanthanum Dioxycarbonate Drug Substance by Potentiometric Titration
This research focused on the determination of lanthanum (LAN) in Lanthanum Dioxycarbonate drug substance through potentiometric titration, a vital aspect in ensuring pharmaceutical...
Electron runaway in ASDEX Upgrade experiments of varying core temperature
Electron runaway in ASDEX Upgrade experiments of varying core temperature
The formation of a substantial postdisruption runaway electron current in ASDEX Upgrade material injection experiments is determined by avalanche multiplication of a small seed pop...
Self-consistent modeling of relativistic runaway electron avalanches producing terrestrial gamma ray flashes
Self-consistent modeling of relativistic runaway electron avalanches producing terrestrial gamma ray flashes
Modélisation auto-consistente d'avalanches d'électrons runaway relativistes produisant des flashs gamma terrestres
Les flashs de rayons gamma terrestres (TGFs) sont...
Characterization of a novel HgCdTe focal plane array for ground and space astronomy through innovative infrared setups
Characterization of a novel HgCdTe focal plane array for ground and space astronomy through innovative infrared setups
(English) Nowadays, mercury-cadmium-telluride (MCT) short-wave infrared (SWIR) detectors are widely used in cutting-edge space
missions and ground-based telescopes. They take adva...
Conceptual design report of the MPD Cosmic Ray Detector (MCORD)
Conceptual design report of the MPD Cosmic Ray Detector (MCORD)
Abstract
This report presents a concept of constructing a detector
dedicated for detection of muons observed during measurements
carried out at the MPD (Multi-Pu...
Nanophotonics with charged particles
Nanophotonics with charged particles
(English) Among the fundamental constituents of matter, charged particles such electrons and positrons are leading protagonists in physical phenomena associated with small (~ meV) ...
Contribution of kinetic electrons in Tokamak plasmas
Contribution of kinetic electrons in Tokamak plasmas
Contribution des électrons cinétiques dans les plasmas de Tokamak
Les plasmas de fusion par confinement magnétique sont le siège d'instabilités qui développent des ...
Modeling terrestrial gamma-ray flashes observed by ASIM
Modeling terrestrial gamma-ray flashes observed by ASIM
<p>The Atmosphere-Space Interactions Monitor (ASIM) on the International Space Station is providing important observations of terrestrial gamma-ray flashes (TGFs), in...

