Javascript must be enabled to continue!
Compansation of Electrical Voltage in Distribution System by Dynamic Voltage Restorer
View through CrossRef
Electrical ac power systems consist of generation systems, transmission and distribution networks. The large three phase industrial loads at various distribution and transmission voltages as well as single-phase residential and commercial loads are supplied by the networks. Nowadays, the power quality such as voltage sags/swell, transient interrupts and harmonic distortions in sinusoidal waveforms are concerned with most of the electrical loads. The power quality problems such as voltage sags, swells and harmonics are caused by the widespread using of power electronics devices in power system. In this paper, electrical voltage sags/swells of power quality problems are considered because this problem is one of the most severe disturbances to the industrial equipment of distribution system. Thus, mitigation of these voltages in distribution system is necessary. So, series connected power electronics based device such as Dynamic Voltage Restorer (DVR) is chosen to compensate these voltage for mitigating quickly the voltage sag/swell in the system and restoring the load voltage to the nominal value. For case study, Myaungtagar industrial zone is chosen due to furnaces and large motor drives that cause the common problems such as voltage sag/swell in this system. In this paper, performance analysis of voltage sag/swell compensation of power distribution system with Dynamic Voltage Restorer (DVR) under various fault conditions is carried out. The proposed configuration model uses MATLAB/SIMULINK and the performance of voltage compensation and restoration of load voltage to the nominal value with DVR under various fault conditions is verified by the simulation results.
Lembaga Penelitian dan Pengabdian kepada Masyarakat ITS
Title: Compansation of Electrical Voltage in Distribution System by Dynamic Voltage Restorer
Description:
Electrical ac power systems consist of generation systems, transmission and distribution networks.
The large three phase industrial loads at various distribution and transmission voltages as well as single-phase residential and commercial loads are supplied by the networks.
Nowadays, the power quality such as voltage sags/swell, transient interrupts and harmonic distortions in sinusoidal waveforms are concerned with most of the electrical loads.
The power quality problems such as voltage sags, swells and harmonics are caused by the widespread using of power electronics devices in power system.
In this paper, electrical voltage sags/swells of power quality problems are considered because this problem is one of the most severe disturbances to the industrial equipment of distribution system.
Thus, mitigation of these voltages in distribution system is necessary.
So, series connected power electronics based device such as Dynamic Voltage Restorer (DVR) is chosen to compensate these voltage for mitigating quickly the voltage sag/swell in the system and restoring the load voltage to the nominal value.
For case study, Myaungtagar industrial zone is chosen due to furnaces and large motor drives that cause the common problems such as voltage sag/swell in this system.
In this paper, performance analysis of voltage sag/swell compensation of power distribution system with Dynamic Voltage Restorer (DVR) under various fault conditions is carried out.
The proposed configuration model uses MATLAB/SIMULINK and the performance of voltage compensation and restoration of load voltage to the nominal value with DVR under various fault conditions is verified by the simulation results.
Related Results
Modelado de un Recuperador Dinámico de Tensión para el Mejoramiento de la Calidad de la Onda de Tensión
Modelado de un Recuperador Dinámico de Tensión para el Mejoramiento de la Calidad de la Onda de Tensión
[1] R. C. Dugan, H. W. Beaty, y S. Santoso, Electrical Power Systems Quality, Third edition. Tata McGraw Hill Education, 2012.[2] J. Arrilaga y N. R. Watson, Powe...
EPD Electronic Pathogen Detection v1
EPD Electronic Pathogen Detection v1
Electronic pathogen detection (EPD) is a non - invasive, rapid, affordable, point- of- care test, for Covid 19 resulting from infection with SARS-CoV-2 virus. EPD scanning techno...
A preliminary identification ofRf*-A619, a novel restorer gene for CMS-C in maize (Zea maysL.)
A preliminary identification ofRf*-A619, a novel restorer gene for CMS-C in maize (Zea maysL.)
C-type cytoplasmic male sterility (CMS-C) is widely utilized for hybrid maize seed production. However, genetic mechanisms underlying the fertility restoration are very complicated...
Genetics of male sterility in gynodioecious Plantago coronopus. II. Nuclear genetic variation.
Genetics of male sterility in gynodioecious Plantago coronopus. II. Nuclear genetic variation.
Abstract
Inheritance of male sterility was studied in the gynodioecious species Plantago coronopus using five plants and their descendants from an area of approximat...
Comparative Analysis between Dynamic Voltage Restorer and PWM-Switched Autotransformer in Voltage Sag Mitigation
Comparative Analysis between Dynamic Voltage Restorer and PWM-Switched Autotransformer in Voltage Sag Mitigation
This research aims to address the problem of voltage sag, which is a significant power quality issue in power systems. Voltage sag can lead to power transmission and distribution l...
Characteristics of Various Single Wind-Power Distributed Generation Placements for Voltage Drop Improvement in a 22 kV Distribution System
Characteristics of Various Single Wind-Power Distributed Generation Placements for Voltage Drop Improvement in a 22 kV Distribution System
A major challenge in distribution systems is the issue of voltage drop along the distribution line resulting from an increased load capacity connected to the utility. A significant...
Electromagnetic Compatibility of Compensating Devices and Converters of an Adjustable Electric Drive in Electrical Networks of Industrial Enterprises
Electromagnetic Compatibility of Compensating Devices and Converters of an Adjustable Electric Drive in Electrical Networks of Industrial Enterprises
The problems of reactive power compensation and improving the quality of electrical energy in the power supply systems of industrial enterprises are inseparable. Their relevance is...
Improving Power Quality with Non-Segregated Dynamic Voltage Restorer-Ultra capacitor Design
Improving Power Quality with Non-Segregated Dynamic Voltage Restorer-Ultra capacitor Design
A product that might improve voltage sag and swell change and integration of energy storage is the dynamic voltage restorer (DVR). Ultra capacitors, or UCAPs, are conducive in reli...

