Javascript must be enabled to continue!
Acetabular index and acetabular depth ratio in newborns and infants aged 6 months or less with the healthy development of hips: A retrospective cross-sectional study
View through CrossRef
Radiographic assessment of the hip may render critical in the diagnosis of developmental dysplasia of the hip (DDH) in newborns and infants aged ≤6 months. There is no complete dataset on the acetabular index (AI) and acetabular depth ratio (ADR) values in this age group. The objective of this study was to assess the AI and ADR values in newborns and infants aged ≤6 months with healthy development. A retrospective analysis was performed on pelvic radiographs of newborns and infants (≤6 months) between August 2020 and September 2021. There were 3000 children with pelvic radiographic imaging. Normal sonographic findings and radiographs without any structural deformity of the hip were inclusion criteria. A total of 1132 newborns and infants (2264 hips) were analyzed. Measurements of AI and ADR (ischium and pubic bone as landmarks for acetabular depth ratio A [ADR-A] and acetabular depth ratio B [ADR-B]) were performed. Correlation and intraclass correlation coefficient (ICC) values were calculated. Left-sided AI values were significantly higher than the right-sided AI values, except in infants aged 4 to ≤5 months (P < .05). ADR-B values differed significantly between male and female newborns and infants both in terms of the side of the hip measured and age (P < .05). AI values were fairly correlated with age (r = −0.286 for left and r = −0.254 for right) in the negative direction and with ADR-A (r = 0.449 and r = 0.469 for left and right) and ADR-B (r = 0.545 and r = 0.592 for left and right) in the positive direction. Inter-observer ICC was 0.845 to 0.989 (excellent) for AI, 0.534 and 0.904 (moderate to excellent) for ADR-A, and −0.014 and 0.774 (slightly good to good) for ADR-B. Intra-observer ICC was 0.811 to 0.996 (excellent) for AI, 0.575 to 0.98 (moderate to excellent) for ADR-A, and 0.023 to 0.954 (slightly good to excellent) for ADR-B. This study features the first complete data set of AI and ADR measurements, which are essential for pelvic radiographic imaging of hip dysplasia, in newborns and infants aged ≤6 months.
Ovid Technologies (Wolters Kluwer Health)
Title: Acetabular index and acetabular depth ratio in newborns and infants aged 6 months or less with the healthy development of hips: A retrospective cross-sectional study
Description:
Radiographic assessment of the hip may render critical in the diagnosis of developmental dysplasia of the hip (DDH) in newborns and infants aged ≤6 months.
There is no complete dataset on the acetabular index (AI) and acetabular depth ratio (ADR) values in this age group.
The objective of this study was to assess the AI and ADR values in newborns and infants aged ≤6 months with healthy development.
A retrospective analysis was performed on pelvic radiographs of newborns and infants (≤6 months) between August 2020 and September 2021.
There were 3000 children with pelvic radiographic imaging.
Normal sonographic findings and radiographs without any structural deformity of the hip were inclusion criteria.
A total of 1132 newborns and infants (2264 hips) were analyzed.
Measurements of AI and ADR (ischium and pubic bone as landmarks for acetabular depth ratio A [ADR-A] and acetabular depth ratio B [ADR-B]) were performed.
Correlation and intraclass correlation coefficient (ICC) values were calculated.
Left-sided AI values were significantly higher than the right-sided AI values, except in infants aged 4 to ≤5 months (P < .
05).
ADR-B values differed significantly between male and female newborns and infants both in terms of the side of the hip measured and age (P < .
05).
AI values were fairly correlated with age (r = −0.
286 for left and r = −0.
254 for right) in the negative direction and with ADR-A (r = 0.
449 and r = 0.
469 for left and right) and ADR-B (r = 0.
545 and r = 0.
592 for left and right) in the positive direction.
Inter-observer ICC was 0.
845 to 0.
989 (excellent) for AI, 0.
534 and 0.
904 (moderate to excellent) for ADR-A, and −0.
014 and 0.
774 (slightly good to good) for ADR-B.
Intra-observer ICC was 0.
811 to 0.
996 (excellent) for AI, 0.
575 to 0.
98 (moderate to excellent) for ADR-A, and 0.
023 to 0.
954 (slightly good to excellent) for ADR-B.
This study features the first complete data set of AI and ADR measurements, which are essential for pelvic radiographic imaging of hip dysplasia, in newborns and infants aged ≤6 months.
Related Results
Is Quantitative Radiographic Measurement of Acetabular Version Reliable in Anteverted and Retroverted Hips?
Is Quantitative Radiographic Measurement of Acetabular Version Reliable in Anteverted and Retroverted Hips?
Background
The acetabular version is crucial for hip function, and its accurate assessment is necessary for treating patients with hip disorders. Current studies reveal...
Measurement of safe acetabular medial wall defect size in revision hip arthroplasty with a porous cup
Measurement of safe acetabular medial wall defect size in revision hip arthroplasty with a porous cup
Introduction:
The majority of acetabular revisions can be performed with an uncemented, porous acetabular component with or without bone grafting. These are con...
Cardiovascular Malformations Among Preterm Infants
Cardiovascular Malformations Among Preterm Infants
Objective. Preterm birth and cardiovascular malformations are the 2 most common causes of neonatal and infant death, but there are no published population-based reports on the rela...
The Salter innominate osteotomy does not lead to acetabular retroversion
The Salter innominate osteotomy does not lead to acetabular retroversion
In children with developmental dysplasia of the hip (DDH), Salter’s innominate osteotomy aims to surgically manipulate the acetabulum to increase anterior coverage and aid joint su...
Does Fluoroscopic-Aided Enabling Technology Improve Acetabular Component Position and Reduce Radiation Exposure in Direct Anterior Total Hip Arthroplasty?
Does Fluoroscopic-Aided Enabling Technology Improve Acetabular Component Position and Reduce Radiation Exposure in Direct Anterior Total Hip Arthroplasty?
Accurate acetabular component positioning is crucial for the success of total hip arthroplasty (THA). Malplacement of the acetabular component increases the risk of post-surgery co...
The Transverse Acetabular Ligament: Optimizing Version
The Transverse Acetabular Ligament: Optimizing Version
In total hip arthroplasty (THA), excessive retroversion is associated with posterior instability, anterior impingement, and resultant groin pain. Excessive anteversion can lead to ...
Hip Instability in Down Syndrome: A Focus on Acetabular Retroversion
Hip Instability in Down Syndrome: A Focus on Acetabular Retroversion
Background:
The aim of this study is to compare acetabular anteversion between children with Down syndrome with or without hip instability. The second aim is to report ...
Association of Infant Feeding Practices with Iron Status and Hematologic Parametersin Thai Infants at 6 Months of Age
Association of Infant Feeding Practices with Iron Status and Hematologic Parametersin Thai Infants at 6 Months of Age
Abstract
Background: An infant's iron intake in the first 6 months of life comes solely from milk intake. However, infants' feeding practices vary, and their association wi...