Javascript must be enabled to continue!
Incomplete Caval Protection Following Suprarenal Caval Filter Placement
View through CrossRef
Inferior vena cava filters are increasingly utilized to prevent pulmonary emboli origi nating from lower extremity, pelvis, or caval thromboses. Unique indications exist for filter placement in the suprarenal portion of the vena cava. The largest reported experi ence in suprarenal position has involved the use of the Greenfield filter. Although unique in design, little differences have been described between the stainless steel and titanium version of this device. The authors present a case report of incomplete caval protection after successful placement of a stainless steel Greenfield filter in the suprarenal cava. Subtle differences between the titanium and the stainless steel Greenfield filter may exist and should be taken into consideration for placement in the suprarenal cava. Physiologic conditions supporting this premise are described. Further investigation between the two filter types appears justified.
Title: Incomplete Caval Protection Following Suprarenal Caval Filter Placement
Description:
Inferior vena cava filters are increasingly utilized to prevent pulmonary emboli origi nating from lower extremity, pelvis, or caval thromboses.
Unique indications exist for filter placement in the suprarenal portion of the vena cava.
The largest reported experi ence in suprarenal position has involved the use of the Greenfield filter.
Although unique in design, little differences have been described between the stainless steel and titanium version of this device.
The authors present a case report of incomplete caval protection after successful placement of a stainless steel Greenfield filter in the suprarenal cava.
Subtle differences between the titanium and the stainless steel Greenfield filter may exist and should be taken into consideration for placement in the suprarenal cava.
Physiologic conditions supporting this premise are described.
Further investigation between the two filter types appears justified.
Related Results
Correlation of Caval Index and Central Venous Pressure in Non-ventilated Critically ill Patients
Correlation of Caval Index and Central Venous Pressure in Non-ventilated Critically ill Patients
Background: Determination of intravascular volume status can sometimes be challenging part of critically ill patient’s management in ICU. Invasive haemodynamic monitoring of centra...
Inferior Vena Caval Filter Placement Without Preoperative Venacavography
Inferior Vena Caval Filter Placement Without Preoperative Venacavography
Despite the emergence of noninvasive studies as the gold standard of venous diagnosis, many authors still insist upon formal preoperative venacavograms prior to insertion of an inf...
CFD Simulation and Optimization of a Cake Filtration System
CFD Simulation and Optimization of a Cake Filtration System
Abstract
This study presents a simulation of filter cake formation during the filtration of rice hull ash and liquid mixture using ANSYS Fluent software. Filter cake...
Limited Benefit Gained From Inferior Vena Cava Filter Insertion In Patients With Advanced-Stage Cancer
Limited Benefit Gained From Inferior Vena Cava Filter Insertion In Patients With Advanced-Stage Cancer
Abstract
Introduction
Cancer and its treatment are recognized risk factors for venous thromboembolism (VTE). Inf...
Effect of stent graft fixation types on pararenal aortic diameter and renal function after endovascular aortic repair
Effect of stent graft fixation types on pararenal aortic diameter and renal function after endovascular aortic repair
Background:
This study aims to identify pararenal aortic diameter changes following endovascular aortic repair and to investigate the effects of suprarenal fixa...
A reappraisal of the sinus venosus defect
A reappraisal of the sinus venosus defect
Abstract
OBJECTIVES
The phenotypic features and morphogenesis of the ‘sinus venosus defect’ remain controversial...
Cigarettes with defective filters marketed for 40 years: what Philip Morris never told smokers: Table 1
Cigarettes with defective filters marketed for 40 years: what Philip Morris never told smokers: Table 1
Background: More than 90% of the cigarettes sold worldwide have a filter. Nearly all filters consist of a rod of numerous ( > 12 000) plastic-like cellulose acetate fibres. Duri...
Optimal design of LCL filter in grid‐connected inverters
Optimal design of LCL filter in grid‐connected inverters
As an essential part in technologies for energy storage systems (ESSs) or renewable energy systems (RESs), grid‐connected inverters need power passive filters to meet grid regulati...

