Air Damper Effect on Temperature and Airflow Distribution in Enhancing Thermal Comfort Performance
View through CrossRef
Heating, ventilating, and air-conditioning (HVAC) technology keeps growing towards providing people with good thermal comfort and indoor air quality. Most buildings use a centralized air-conditioning system in which the air-handling configuration of variable air volume (VAV) system focuses on controlling the zone temperature. But, some of the areas in the zone facing under-actuated and over-actuated airflow lead to the distortion of thermal comfort. Some indoor areas get too cold, and some get too hot due to improper air distribution. The indoor temperature inconsistency will affect the occupants' productivity and work performance. The main focus of this research is to improve the indoor environment's thermal performance by implementing an active air damper as an air controlling device for a centralized air-conditioning system. Indirectly, this will provide the control of temperature for a specific area in the zone with a VAV system. This paper presents the simulation results on the effect of the air damper pattern and its opening parameter against the temperature and airflow distribution in enhancing the thermal comfort performance. The simulation was performed using Ansys FLUENT to analyze three types of air damper patterns: iris, butterfly and radial. The comparison of CFD simulation results shows that the iris damper pattern can provide an acceptable range of temperature of 22 ºC to 24 ºC, which is significant to the desired thermal comfort. The uniform airflow distribution across the indoor area is obtained with no back-flow form in the ducting. Besides, there is a substantial temperature increment when the opening area of inlet airflow is reduced. Therefore, it can be concluded that the iris damper pattern is the best selection for an active air damper since it can provide the best temperature and air flow distribution performance compared to the butterfly and radial air damper.
Title: Air Damper Effect on Temperature and Airflow Distribution in Enhancing Thermal Comfort Performance
Description:
Heating, ventilating, and air-conditioning (HVAC) technology keeps growing towards providing people with good thermal comfort and indoor air quality.
Most buildings use a centralized air-conditioning system in which the air-handling configuration of variable air volume (VAV) system focuses on controlling the zone temperature.
But, some of the areas in the zone facing under-actuated and over-actuated airflow lead to the distortion of thermal comfort.
Some indoor areas get too cold, and some get too hot due to improper air distribution.
The indoor temperature inconsistency will affect the occupants' productivity and work performance.
The main focus of this research is to improve the indoor environment's thermal performance by implementing an active air damper as an air controlling device for a centralized air-conditioning system.
Indirectly, this will provide the control of temperature for a specific area in the zone with a VAV system.
This paper presents the simulation results on the effect of the air damper pattern and its opening parameter against the temperature and airflow distribution in enhancing the thermal comfort performance.
The simulation was performed using Ansys FLUENT to analyze three types of air damper patterns: iris, butterfly and radial.
The comparison of CFD simulation results shows that the iris damper pattern can provide an acceptable range of temperature of 22 ºC to 24 ºC, which is significant to the desired thermal comfort.
The uniform airflow distribution across the indoor area is obtained with no back-flow form in the ducting.
Besides, there is a substantial temperature increment when the opening area of inlet airflow is reduced.
Therefore, it can be concluded that the iris damper pattern is the best selection for an active air damper since it can provide the best temperature and air flow distribution performance compared to the butterfly and radial air damper.
Related Results
Pre-Optimization of Asymmetrical Underplatform Dampers
Pre-Optimization of Asymmetrical Underplatform Dampers
The numerical coupled optimization of an underplatform damper is the exploration of its dynamics through a finite element model which includes both the damper and the blades. This ...
Optimal Design Methodology of Maxwell Coulomb Friction Damper
Optimal Design Methodology of Maxwell Coulomb Friction Damper
An optimal design methodology of Maxwell Coulomb friction damper is proposed for minimization of resonant vibration of dynamic structures. The simple Coulomb friction damper has th...
Thermal energy storage with tunnels in different subsurface conditions
Thermal energy storage with tunnels in different subsurface conditions
The widespread use of the underground and global climate change impact the urban subsurface temperature. Changes in the subsurface environment can affect the performance of undergr...
Could Mobile Air Supply Unit Enhance Airflow Distribution in Office Environments?
Could Mobile Air Supply Unit Enhance Airflow Distribution in Office Environments?
Effective airflow management in office settings is crucial for good indoor air quality and occupant comfort. Poor air circulation can lead to health issues like increased respirato...
SOCIALIZATION OF THERMAL COMFORT STANDARDS AT SMKN 4 SOUTH TANGERANG
SOCIALIZATION OF THERMAL COMFORT STANDARDS AT SMKN 4 SOUTH TANGERANG
Vocational High School (SMK) is a formal education unit that provides education that prepares students to work in specific fields. Students can continue their vocational education ...
THE EFFECT OF THERMAL COMFORT ON THE HEALTH OF OCCUPANTS AT CITRA GRAHA HOUSING
THE EFFECT OF THERMAL COMFORT ON THE HEALTH OF OCCUPANTS AT CITRA GRAHA HOUSING
Humans mostly spend much time indoors, which is residential houses, so it is necessary to pay attention to thermal comfort because thermal comfort is closely related to health. Sim...
Study on Urban Thermal Environment based on Diurnal Temperature Range
Study on Urban Thermal Environment based on Diurnal Temperature Range
<p>Diurnal temperature range (includes land surface temperature diurnal range and near surface air temperature diurnal range) is an important meteorological parameter...
A Novel Passive Pseudo-Negative Stiffness Damper for Seismic Response Reduction
A Novel Passive Pseudo-Negative Stiffness Damper for Seismic Response Reduction
Abstract
The concept of a pseudo-negative stiffness (PNS) damper using a fluid viscous variable damper has been introduced since early 2000s, which employed a semi-active c...