279-OR: How to Use rtCGM Data to Predict Future Severe Hypoglycemia?
View through CrossRef
We combined rtCGM-baseline-data of the HypoDE and DIAMOND study to predict future severe hypoglycemia (SH; third party assistance for recovery). At baseline, in both studies, the rtCGM system (Dexcom G4) was masked. We analyzed the data of 127 study participants in the control groups with type 1 diabetes (age 46.0 ±11.5 years; diabetes duration 22.4 ±14.1 years, A1c 7.9 ±1.0%) using SMBG during the trials. According to the consensus statement we used the following hypoglycemia-specific predictors: % of glucose values < 70mg/dl and <54 mg/dl, the number of such events, Low Blood Glucose Index (LBGI), and the coefficient of variation (CV). After baseline, a total of 44 severe hypoglycemic events were observed during the following 6-months; with 12.6% affected participants. We analyzed the area under the Receiver Operating Characteristics (ROC) curves and determined cut-off values with an optimal sensitivity and specificity (Table). All hypoglycemia-related parameters, except CV, were able to predict SH during the next 6 months significantly better than prediction by chance; e.g., if ≥ 7% of glucose values were < 70 mg/dl, the probability for SH in the next 6-months was 23.4%. CGM-derived hypoglycemic outcome parameters might help to identify people with diabetes who have an increased risk for future hypoglycemia. These results should be corroborated by non-masked use of rtCGM but might also be useful in patients using SMBG.
Disclosure
N. Hermanns: Advisory Panel; Self; Abbott. Board Member; Self; Eli Lilly and Company. Research Support; Self; Abbott, Berlin-Chemie AG, Dexcom, Inc., Roche Diabetes Care. Speaker's Bureau; Self; Berlin-Chemie AG, Dexcom, Inc., Novo Nordisk A/S. D. Ehrmann: Advisory Panel; Self; Medtronic. Speaker's Bureau; Self; Abbott, Berlin-Chemie AG, Dexcom, Inc. P. Calhoun: Stock/Shareholder; Self; Dexcom, Inc. G. Freckmann: Advisory Panel; Self; Abbott, Novo Nordisk Pharma GmbH, Sensile Medical AG. Consultant; Self; Metronom Health Europe, Roche Diabetes Care, Sanofi. Speaker's Bureau; Self; Ascensia Diabetes Care, Dexcom, Inc., Ypsomed AG. L. Heinemann: Consultant; Self; Roche Diabetes Care. Research Support; Self; Dexcom, Inc. Stock/Shareholder; Self; Profil Institute for Metabolic Research, ProSciento.
Funding
Dexcom, Inc.
American Diabetes Association
Title: 279-OR: How to Use rtCGM Data to Predict Future Severe Hypoglycemia?
Description:
We combined rtCGM-baseline-data of the HypoDE and DIAMOND study to predict future severe hypoglycemia (SH; third party assistance for recovery).
At baseline, in both studies, the rtCGM system (Dexcom G4) was masked.
We analyzed the data of 127 study participants in the control groups with type 1 diabetes (age 46.
0 ±11.
5 years; diabetes duration 22.
4 ±14.
1 years, A1c 7.
9 ±1.
0%) using SMBG during the trials.
According to the consensus statement we used the following hypoglycemia-specific predictors: % of glucose values < 70mg/dl and <54 mg/dl, the number of such events, Low Blood Glucose Index (LBGI), and the coefficient of variation (CV).
After baseline, a total of 44 severe hypoglycemic events were observed during the following 6-months; with 12.
6% affected participants.
We analyzed the area under the Receiver Operating Characteristics (ROC) curves and determined cut-off values with an optimal sensitivity and specificity (Table).
All hypoglycemia-related parameters, except CV, were able to predict SH during the next 6 months significantly better than prediction by chance; e.
g.
, if ≥ 7% of glucose values were < 70 mg/dl, the probability for SH in the next 6-months was 23.
4%.
CGM-derived hypoglycemic outcome parameters might help to identify people with diabetes who have an increased risk for future hypoglycemia.
These results should be corroborated by non-masked use of rtCGM but might also be useful in patients using SMBG.
Disclosure
N.
Hermanns: Advisory Panel; Self; Abbott.
Board Member; Self; Eli Lilly and Company.
Research Support; Self; Abbott, Berlin-Chemie AG, Dexcom, Inc.
, Roche Diabetes Care.
Speaker's Bureau; Self; Berlin-Chemie AG, Dexcom, Inc.
, Novo Nordisk A/S.
D.
Ehrmann: Advisory Panel; Self; Medtronic.
Speaker's Bureau; Self; Abbott, Berlin-Chemie AG, Dexcom, Inc.
P.
Calhoun: Stock/Shareholder; Self; Dexcom, Inc.
G.
Freckmann: Advisory Panel; Self; Abbott, Novo Nordisk Pharma GmbH, Sensile Medical AG.
Consultant; Self; Metronom Health Europe, Roche Diabetes Care, Sanofi.
Speaker's Bureau; Self; Ascensia Diabetes Care, Dexcom, Inc.
, Ypsomed AG.
L.
Heinemann: Consultant; Self; Roche Diabetes Care.
Research Support; Self; Dexcom, Inc.
Stock/Shareholder; Self; Profil Institute for Metabolic Research, ProSciento.
Funding
Dexcom, Inc.
Related Results
Predictors of Hypoglycemia Avoidance in a Randomized Controlled rtCGM Trial (HypoDE)
Predictors of Hypoglycemia Avoidance in a Randomized Controlled rtCGM Trial (HypoDE)
The HypoDE study, a randomized multi-center trial, showed that rtCGM use reduces the number of low glucose events (<55 mg/dl for at least 20 minutes) per 28 days from 10.4 t...
Lainoja ja lainakerrostumia
Lainoja ja lainakerrostumia
Lehnwörter und Entlehnungsschichten (saksa)Kielenaineksetabras (kieli: viro, sivulla: 275)aho (kieli: suomi, sivulla: 274)aisa (kieli: suomi, sivulla: 269)ansa (kieli: suomi, sivul...
281-OR: Directness and Sustainability of rtCGM Effects on Hypoglycemia: A Secondary Analysis of the Hypode Study
281-OR: Directness and Sustainability of rtCGM Effects on Hypoglycemia: A Secondary Analysis of the Hypode Study
The HypoDE study demonstrated that real-time continuous glucose monitoring (rtCGM) can reduce biochemical as well as clinical hypoglycemia in people with hypoglycemia problems. How...
Hypoglycemia
Hypoglycemia
AbstractIatrogenic hypoglycemia often causes recurrent morbidity and precludes maintenance of lifelong euglycemia in people with diabetes mellitus. It causes an array of neurogenic...
Hypoglycemia Subtypes in Type 1 Diabetes: An Exploration of the Hypoglycemia Fear Survey-II
Hypoglycemia Subtypes in Type 1 Diabetes: An Exploration of the Hypoglycemia Fear Survey-II
<i>Objectives: </i>The Hypoglycemia Fear Survey II (HFS-II) is a
well-validated measure of fear of hypoglycemia in people with type 1
diabetes. The aim of this study w...
Hypoglycemia Subtypes in Type 1 Diabetes: An Exploration of the Hypoglycemia Fear Survey-II
Hypoglycemia Subtypes in Type 1 Diabetes: An Exploration of the Hypoglycemia Fear Survey-II
<i>Objectives: </i>The Hypoglycemia Fear Survey II (HFS-II) is a
well-validated measure of fear of hypoglycemia in people with type 1
diabetes. The aim of this study w...
Ghrelin does not impact the blunted counterregulatory response to recurrent hypoglycemia in mice
Ghrelin does not impact the blunted counterregulatory response to recurrent hypoglycemia in mice
IntroductionRecurrent episodes of insulin-induced hypoglycemia in patients with diabetes mellitus can result in hypoglycemia-associated autonomic failure (HAAF), which is character...
Severe Hypoglycemia in Children With IDDM: A prospective population study, 1992–1994
Severe Hypoglycemia in Children With IDDM: A prospective population study, 1992–1994
OBJECTIVE
Is an increased incidence of severe hypoglycemia an unavoidable effect of improved metabolic control? And, if so, to what extent?
...