Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Three years performance of Biodegradable Polymer Sirolimus Eluting Stent in all comer patients undergoing Percutaneous Coronary Intervention.

View through CrossRef
Introduction: Contemporary evidence suggest the comparable performance of biodegradable polymer sirolimus eluting stents (BPSES) with that of second generation durable polymer drug eluting stents. This study was done to evaluate the performance of BPSES in all comer patients undergoing percutaneous intervention (PCI) in real world setting over a period of three years. Materials & Methods: This was a prospective observational study, wherein all comer consecutive patients undergoing PCI with BPSES (Yukon Choice Elite stent by Translumina Therapeutics, India) were enrolled and followed up for 3 years. The study's primary endpoint was the Device Oriented Composite Endpoint (DOCE), which included cardiac death, target vessel myocardial infarction (MI), and clinically driven target lesion revascularization (TLR); the co-primary endpoint was the Patient-Oriented Composite Endpoint (POCE), which included all-cause mortality, any MI , and any repeat revascularization and the secondary endpoint was definite or probable stent thrombosis (DST & PST). Results: 301 patients with 502 lesions were treated with 485 BP-SES. Mean age of the study cohort was 61.6± 9.3 yrs and males were 79.1%. 18.6% patients were diabetic, 29.6% had ejection fraction less than 40% and 73.1% patients presented with acute coronary syndrome (ACS). Majority of the patient had triple vessel disease (TVD) (51.8%), multivessel PCI was done in 15.6% and complex PCI in 26.2% patients. A mean of 1.6 ±0.8 stents per patient with mean diameter 3.0 ± 0.3 mm and mean length of 27.2 ± 0.8 mm were placed. DOCE & POCE occurred in 7.9% (cardiac death-4.8%, TLR-2.6% & target vessel MI-0.4%) and 12.8% (All deaths-9.7%, any MI- 0.4% and any revascularisation-2.6%) patients respectively at three years follow-up. DST & PST rate was 0.9% and 0.4% respectively in the study cohort. All the cases of stent thrombosis occurred within 30 days. Kaplan Meier analysis revealed that diabetes mellitus, low ejection fraction (EF), acute coronary syndrome (ACS), long stents and complex intervention had no impact on occurrence of DOCE & POCE while using BP-SES in all-comer patient population. Conclusion: Present study showed favourable long term safety and efficacy profile of BP-SES for all-comer patients undergoing PCI.
Title: Three years performance of Biodegradable Polymer Sirolimus Eluting Stent in all comer patients undergoing Percutaneous Coronary Intervention.
Description:
Introduction: Contemporary evidence suggest the comparable performance of biodegradable polymer sirolimus eluting stents (BPSES) with that of second generation durable polymer drug eluting stents.
This study was done to evaluate the performance of BPSES in all comer patients undergoing percutaneous intervention (PCI) in real world setting over a period of three years.
Materials & Methods: This was a prospective observational study, wherein all comer consecutive patients undergoing PCI with BPSES (Yukon Choice Elite stent by Translumina Therapeutics, India) were enrolled and followed up for 3 years.
The study's primary endpoint was the Device Oriented Composite Endpoint (DOCE), which included cardiac death, target vessel myocardial infarction (MI), and clinically driven target lesion revascularization (TLR); the co-primary endpoint was the Patient-Oriented Composite Endpoint (POCE), which included all-cause mortality, any MI , and any repeat revascularization and the secondary endpoint was definite or probable stent thrombosis (DST & PST).
Results: 301 patients with 502 lesions were treated with 485 BP-SES.
Mean age of the study cohort was 61.
6± 9.
3 yrs and males were 79.
1%.
18.
6% patients were diabetic, 29.
6% had ejection fraction less than 40% and 73.
1% patients presented with acute coronary syndrome (ACS).
Majority of the patient had triple vessel disease (TVD) (51.
8%), multivessel PCI was done in 15.
6% and complex PCI in 26.
2% patients.
A mean of 1.
6 ±0.
8 stents per patient with mean diameter 3.
0 ± 0.
3 mm and mean length of 27.
2 ± 0.
8 mm were placed.
DOCE & POCE occurred in 7.
9% (cardiac death-4.
8%, TLR-2.
6% & target vessel MI-0.
4%) and 12.
8% (All deaths-9.
7%, any MI- 0.
4% and any revascularisation-2.
6%) patients respectively at three years follow-up.
DST & PST rate was 0.
9% and 0.
4% respectively in the study cohort.
All the cases of stent thrombosis occurred within 30 days.
Kaplan Meier analysis revealed that diabetes mellitus, low ejection fraction (EF), acute coronary syndrome (ACS), long stents and complex intervention had no impact on occurrence of DOCE & POCE while using BP-SES in all-comer patient population.
Conclusion: Present study showed favourable long term safety and efficacy profile of BP-SES for all-comer patients undergoing PCI.

Related Results

Biodegradable-Polymer or Durable-Polymer Stents in Patients at High Bleeding Risk: A Randomized, Open-Label Clinical Trial
Biodegradable-Polymer or Durable-Polymer Stents in Patients at High Bleeding Risk: A Randomized, Open-Label Clinical Trial
BACKGROUND: Limited information is available on the comparative efficacy and safety of different stent platforms in patients at high bleeding risk undergoing an abbrevi...
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Early Onset of Coronary Subclavian Steal Syndrome: A Case Report and Literature Review
Abstract Introduction Coronary subclavian steal syndrome (CSSS) is a rare phenomenon that often goes undiagnosed and causes severe complications, including death. This report prese...
Clinical study of biodegradable polymer stent versus durable polymer stent in treating long coronary lesions
Clinical study of biodegradable polymer stent versus durable polymer stent in treating long coronary lesions
Objective This study compared the clinical efficacy and safety of homemade biodegradable polymer rapamycin-eluting stent (EXCEL TM) and durable polymer rapamycin-...
Predictors of insistent restenosis in patients undergoing percutaneous intervention
Predictors of insistent restenosis in patients undergoing percutaneous intervention
Coronary artery disease is one of the leading causes of morbidity and mortality worldwide. The first percutaneous coronary intervention was performed by Andreas Gruntzig on Septemb...
Sirolimus PK trial: A pharmacokinetic study of the sirolimus‐eluting Bx Velocity stent in patients with de novo coronary lesions
Sirolimus PK trial: A pharmacokinetic study of the sirolimus‐eluting Bx Velocity stent in patients with de novo coronary lesions
AbstractThis study was conducted to assess the systemic drug release and distribution of sirolimus‐eluting stents. Early results with sirolimus‐eluting stents have demonstrated a f...
Incidence and Management of In-Stent Restenosis in Patients with Drug-Eluting Stents
Incidence and Management of In-Stent Restenosis in Patients with Drug-Eluting Stents
Introduction: The most prevalent complication of cardiac intervention is restenosis. After the BMS period, drug-eluting stents (DES) are the most suitable choice for stenosis treat...
Effectiveness and safety of the sirolimus‐eluting stents coated with bioabsorbable polymer coating in human coronary arteries
Effectiveness and safety of the sirolimus‐eluting stents coated with bioabsorbable polymer coating in human coronary arteries
AbstractBackground: Although the sirolimus‐eluting stent (CYPHER®, Cordis, USA) has shown a dramatic reduction of restenosis, there are still some concerns about its efficacy and s...

Back to Top