Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Ultrasonographic Diagnosis of Slipped Capital Femoral Epiphysis

View through CrossRef
<b>Background</b>: Slipped capital femoral epiphysis (SCFE), a fracture through the physis with resultant slip of the epiphysis, is the most common hip abnormality in adolescents and is a major cause of early osteoarthritis. Plain radiograph is the initial modality used to evaluate patients with painful hip joints. Ultrasonography and magnetic resonance imaging (MRI), which do not involve radiation exposure, have also been used. This case report supports the view that ultrasound can be used as an initial, cost-effective and radiation-free modality for the evaluation of suspected SCFE.<br /> <b>Case Report</b>: A 15-year-old male patient presented with pain in the right hip for 5 days, following a slip and fall accident while playing soccer. The patient was referred to the Department of Radio-diagnosis for ultrasound. A posterior displacement of the femoral head epiphysis with a physeal step was seen on the longitudinal section obtained over the right hip joint region. The anterior physeal step (APS) measured ~3.8 mm on the right side. The distance between the anterior rim of the acetabulum and the metaphysis measured ~20.4 mm on the affected right side and ~23.6 mm on the left side. A plain radiograph in frog leg position showed a widening of the right proximal physis below the right femoral head, with a medial and posterior slip of the right femoral head. A frontal radiograph of the pelvis taken six months before showed a widening of the proximal right femoral physis.<br /> <b>Conclusions</b>: Although MRI appears to be the most sensitive modality for identifying slips early, ultrasound may be used as a cost-effective and radiation-free alternative before proceeding with further evaluation of suspected SCFE, especially considering the demographics of the affected population.
Title: Ultrasonographic Diagnosis of Slipped Capital Femoral Epiphysis
Description:
<b>Background</b>: Slipped capital femoral epiphysis (SCFE), a fracture through the physis with resultant slip of the epiphysis, is the most common hip abnormality in adolescents and is a major cause of early osteoarthritis.
Plain radiograph is the initial modality used to evaluate patients with painful hip joints.
Ultrasonography and magnetic resonance imaging (MRI), which do not involve radiation exposure, have also been used.
This case report supports the view that ultrasound can be used as an initial, cost-effective and radiation-free modality for the evaluation of suspected SCFE.
<br /> <b>Case Report</b>: A 15-year-old male patient presented with pain in the right hip for 5 days, following a slip and fall accident while playing soccer.
The patient was referred to the Department of Radio-diagnosis for ultrasound.
A posterior displacement of the femoral head epiphysis with a physeal step was seen on the longitudinal section obtained over the right hip joint region.
The anterior physeal step (APS) measured ~3.
8 mm on the right side.
The distance between the anterior rim of the acetabulum and the metaphysis measured ~20.
4 mm on the affected right side and ~23.
6 mm on the left side.
A plain radiograph in frog leg position showed a widening of the right proximal physis below the right femoral head, with a medial and posterior slip of the right femoral head.
A frontal radiograph of the pelvis taken six months before showed a widening of the proximal right femoral physis.
<br /> <b>Conclusions</b>: Although MRI appears to be the most sensitive modality for identifying slips early, ultrasound may be used as a cost-effective and radiation-free alternative before proceeding with further evaluation of suspected SCFE, especially considering the demographics of the affected population.

Related Results

Angiographic evaluation of femoral bifurcation in Chinese population
Angiographic evaluation of femoral bifurcation in Chinese population
Objective Common femoral artery (CFA) access has been proved to be safe with lower risk of complications in percutaneous catheterisation. The femoral head can be ...
MONGOLIAN AND HAN NATIONALITY RIGHT FEMORAL ARTERY BIFURCATION ANALYSIS BY ANGIOGRAPHY
MONGOLIAN AND HAN NATIONALITY RIGHT FEMORAL ARTERY BIFURCATION ANALYSIS BY ANGIOGRAPHY
Objectives To analyze the variation of Mongolian and Han nationality in the site of femoral artery bifurcation relying on the femoral head and the pulic symphysis...
Radiographic analysis of the proximal femoral anatomy in the Croatian population
Radiographic analysis of the proximal femoral anatomy in the Croatian population
Abstract Purpose The goal of total hip endoprosthesis is to achieve painless and functional hip for long term. Accurate reconstruction of hip anatom...
A medial circumflex femoral artery passing anteriorly to the femoral vein: report of a bilateral case
A medial circumflex femoral artery passing anteriorly to the femoral vein: report of a bilateral case
The passage of the medial circumflex femoral artery anterior to the femoral vein is an extremely rare anatomical variation. It can lead to  an iatrogenic arteiovenous fistula after...
Intellectual Capital and the Performance of Manufacturing Companies in Indonesia
Intellectual Capital and the Performance of Manufacturing Companies in Indonesia
ARTICLE INFO  ABSTRACT Keywords:Intellectual capital, value added capital employed, value added human capital, structural capital value added, return on asset, return on equity, ma...
Stress-specific differences in Distal Femoral Epiphysis of Leg Length Discrepancy and Pelvic Tilt. A Finite-Element Analysis
Stress-specific differences in Distal Femoral Epiphysis of Leg Length Discrepancy and Pelvic Tilt. A Finite-Element Analysis
Abstract Objective This study aimed to compare the distal femoral epiphyseal stress of Leg Length Discrepancy and Pelvic Tilt, to explain the phenomenon of genu varum and ...

Back to Top