Javascript must be enabled to continue!
Aberration Generation by Contact Lenses With Aspheric and Asymmetric Surfaces
View through CrossRef
ABSTRACT
PURPOSE: We explored the potential of aberration correction in the human eye by using a new generation of soft contact lenses with aspheric and asymmetric surfaces.
METHODS: Soft contact lens samples were designed with one asymmetrical surface (front) and one spherical (back) to produce predetermined amounts of desired pure defocus, astigmatism, trefoil, coma, and spherical aberration. Contact lens wavefront aberrations were measured ex vivo using a Fizeau-Tolanski interferometer and compared with the in vivo wavefronts obtained by subtracting the aberrations of the eye with and without the contact lenses. These second set of measurements were obtained using a Snack-Hartmann sensor.
RESULTS: We found that an aberration-free contact lens sample induced in the eye a small amount of residual aberration. We obtained a good match between the ex vivo and in vivo wavefront measurements for most of the samples of the contact lenses.
CONCLUSIONS: The aberrations generated by soft contact lenses on the eye were predictable. Rotations and translations of the contact lenses with respect to correct position on the eye were, however, the main limitation for precise correction of the ocular aberrations. [J Refract Surg 2002;18:S603-S609]
Title: Aberration Generation by Contact Lenses With Aspheric and Asymmetric Surfaces
Description:
ABSTRACT
PURPOSE: We explored the potential of aberration correction in the human eye by using a new generation of soft contact lenses with aspheric and asymmetric surfaces.
METHODS: Soft contact lens samples were designed with one asymmetrical surface (front) and one spherical (back) to produce predetermined amounts of desired pure defocus, astigmatism, trefoil, coma, and spherical aberration.
Contact lens wavefront aberrations were measured ex vivo using a Fizeau-Tolanski interferometer and compared with the in vivo wavefronts obtained by subtracting the aberrations of the eye with and without the contact lenses.
These second set of measurements were obtained using a Snack-Hartmann sensor.
RESULTS: We found that an aberration-free contact lens sample induced in the eye a small amount of residual aberration.
We obtained a good match between the ex vivo and in vivo wavefront measurements for most of the samples of the contact lenses.
CONCLUSIONS: The aberrations generated by soft contact lenses on the eye were predictable.
Rotations and translations of the contact lenses with respect to correct position on the eye were, however, the main limitation for precise correction of the ocular aberrations.
[J Refract Surg 2002;18:S603-S609].
Related Results
Optical and Visual Performance of Aspheric Soft Contact Lenses
Optical and Visual Performance of Aspheric Soft Contact Lenses
ABSTRACT
Purpose.
This study was conducted to investigate whether aspheric design soft contact lenses reduce ocular aberr...
Técnicas de reconstrucción y compensación activa de frentes de onda complejos
Técnicas de reconstrucción y compensación activa de frentes de onda complejos
The continuous improvements of optical design tools and manufacturing technologies of free-form optical elements, allow the creation of new complex-shaped lenses that improve the p...
Design method of zoom systems based on high-order structural aberration coefficients
Design method of zoom systems based on high-order structural aberration coefficients
Optical zoom systems have found widespread applications in fields such as security and mobile phone lenses. The theory of zoom lens design has also developed from the first order t...
Design of aspheric spectacle lenses using non-dominated sorting genetic algorithm
Design of aspheric spectacle lenses using non-dominated sorting genetic algorithm
Significance: An effective algorithm for optimization of lens parameter can greatly eliminate the aberration and reduce the thickness, making the wearer more comfortable. Aim: We p...
Inefficacy of Aspheric Soft Contact Lenses for the Correction of Low Levels of Astigmatism
Inefficacy of Aspheric Soft Contact Lenses for the Correction of Low Levels of Astigmatism
ABSTRACT:
Purpose.
The purpose of this article is to compare the visual performance of a toric soft (TS) contact lens (So...
Knowledge and Practice of Refractive Error Correction in Medical Students of National Defence University of Malaysia
Knowledge and Practice of Refractive Error Correction in Medical Students of National Defence University of Malaysia
Objective: To assess the knowledge and practice of refractive error correction (spectacles and contact lenses) in medical students of National Defence University of Malaysia using ...
Effect of chromatic aberration on performance of concentrated multi-junction solar cells and their optimization
Effect of chromatic aberration on performance of concentrated multi-junction solar cells and their optimization
In order to investigate the influence of the chromatic aberration on the performance of multi-junction solar cells, the performance of the triple-junction GaInP/GaInAs/Ge solar cel...
Progress in Surface Theory
Progress in Surface Theory
The workshop
Progress in Surface Theory
, organised by Uwe Abresch (Bochum), Josef Dorfmeister (München), and Masaaki Umehara (Osaka) was he...

