Effects of sample holder characteristics on thermal diffusivity measurement using the laser flash method
View through CrossRef
The laser flash method is commonly adopted to measure the thermal diffusivity of solid material since its advantages, such as a wide measuring range of thermal diffusivity, a small amount of samples, a high measuring temperature, and so on. However, the sample holders used by this method are limited and costly, which seriously affects the convenience and economy of this method. So, in order to develop and design more kinds of sample holders, it is necessary to study the effects of sample holder characteristics on measuring results. A transient flow and heat transfer calculation model was developed to analyse effects of pulse energy, pulse time, laser beam area, protective gas flow and sample holder materials on the thermal diffusivity measurement. It is found that the temperature increase of the sample upper surface ΔT obviously increases with pulse energy, pulse time and laser beam area increasing, but the half heating up time t50 slightly decreases with theses parameters increasing. ΔT and t50 are independent to the volume flow rate of protective gas. The heat transfer process and mechanism between sample and holders with various materials were analysed. The heat loss of samples depends on the heat conduction and radiation between sample and holder, the heat convection and radiation from sample to protective gas. The thermal conductivity, specific heat and emissivity of holder materials can affect the heat conduction and radiation between sample and holder slightly. So the ΔT and t50 are nearly independent to the holder material properties. Based on these conclusions, a new SUS310 holder was made, and the thermal diffusivity of a sample was experimentally measured using the new holder. As a result, the measuring error is less than ±3%.
Title: Effects of sample holder characteristics on thermal diffusivity measurement using the laser flash method
Description:
The laser flash method is commonly adopted to measure the thermal diffusivity of solid material since its advantages, such as a wide measuring range of thermal diffusivity, a small amount of samples, a high measuring temperature, and so on.
However, the sample holders used by this method are limited and costly, which seriously affects the convenience and economy of this method.
So, in order to develop and design more kinds of sample holders, it is necessary to study the effects of sample holder characteristics on measuring results.
A transient flow and heat transfer calculation model was developed to analyse effects of pulse energy, pulse time, laser beam area, protective gas flow and sample holder materials on the thermal diffusivity measurement.
It is found that the temperature increase of the sample upper surface ΔT obviously increases with pulse energy, pulse time and laser beam area increasing, but the half heating up time t50 slightly decreases with theses parameters increasing.
ΔT and t50 are independent to the volume flow rate of protective gas.
The heat transfer process and mechanism between sample and holders with various materials were analysed.
The heat loss of samples depends on the heat conduction and radiation between sample and holder, the heat convection and radiation from sample to protective gas.
The thermal conductivity, specific heat and emissivity of holder materials can affect the heat conduction and radiation between sample and holder slightly.
So the ΔT and t50 are nearly independent to the holder material properties.
Based on these conclusions, a new SUS310 holder was made, and the thermal diffusivity of a sample was experimentally measured using the new holder.
As a result, the measuring error is less than ±3%.
Related Results
Thermal Effects in High Compactness CEA Stack
Thermal Effects in High Compactness CEA Stack
Thermal management is a pivotal aspect of stack durability and system operability. Consequently, understanding the thermal mapping within a stack based on its operating conditions ...
Dual Laser Method for Experimentally Weathering Planetary Regoliths
Dual Laser Method for Experimentally Weathering Planetary Regoliths
<p>Experimental space weathering&#8212;whether laser, thermal reduction, impact, or ion based&#8212;is a critical endeavor to accurately interpret spa...
Two Successive Lunar Impact Flashes: First lunar impact detection from Turkey
Two Successive Lunar Impact Flashes: First lunar impact detection from Turkey
AbstractA number of attempts have been done to detect of lunar impact flash observations by various researchers in last 20 years. One of the systematically research of lunar impact...
Laser Spectrometric Techniques in Analytical Atomic Spectrometry
Laser Spectrometric Techniques in Analytical Atomic Spectrometry
Abstract
Laser light has a number of spectacular properties that make it useful for analytical spectrometry. One is that it has a high directionality (i.e. i...
Flash Radiation Therapy: Current Insights and Future Prospects
Flash Radiation Therapy: Current Insights and Future Prospects
FLASH radiotherapy (RT) is an innovative approach used in cancer treatment. The FLASH effect is observed at ultra-high dose rates (UHDR) of approximately 40 Gy/s or higher. This tr...
Integration of Deep-Learning-Based Flash Calculation Model to Reservoir Simulator
Integration of Deep-Learning-Based Flash Calculation Model to Reservoir Simulator
Abstract
Flash calculation is an essential step in compositional reservoir simulation. However, it consumes a significant part of the simulation process, leading to ...
LEO-to-GNSS Laser Interferometer for Space Geodesy with Laser DORIS and Laser SAR
LEO-to-GNSS Laser Interferometer for Space Geodesy with Laser DORIS and Laser SAR
In order to increase the accuracy of precise orbit determination for a single satellite or satellites in LEO formation, we propose using a LEO-to-GNSS laser interferometer, what we...
Diffusion of small solutes in cartilage as measured by nuclear magnetic resonance (NMR) spectroscopy and imaging
Diffusion of small solutes in cartilage as measured by nuclear magnetic resonance (NMR) spectroscopy and imaging
AbstractThe ability of water and solutes to move through the cartilage matrix is important to the normal function of cartilage and is presumed to be altered in degenerative disease...