Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Copper, Iron, and Aluminium Electrochemical Corrosion Rates and Intrinsic Diffusivitives Dependence on Temperature Investigations

View through CrossRef
Our investigations show that electrochemical corrosion of copper is faster than electrochemical corrosion of aluminium at temperatures below 100oC. Literature data analysis shows that the Al atoms diffuse faster than the Cu atoms at temperatures higher than 475oC, Al rich intermetallic compounds (IMCs) are formed faster in the Cu-Al system, and the Kirkendall plane shifts toward Al side. Electrochemical corrosion occurs due to electric current and due to diffusion. An electronic devise working time, for example, depends on initial copper cover thickness on aluminium wire, connected to the electronic devise, temperature, and volume and dislocation pipe diffusion coefficients, so copper, iron, and aluminium electrochemical corrosion rates are investigated experimentally at room temperature and at temperature 100oC. Intrinsic diffusivities ratios of copper and aluminium at different temperatures and diffusion activation energies in the Cu-Al system are calculated by proposed here methods using literature experimental data. Dislocation pipe and volume diffusion activation energies of pure iron are calculated separately by earlier proposed method using literature experimental data. Aluminium dissolved into NaCl solution as the Al3+ ions at room temperature and at temperature 100oC, iron dissolved into NaCl solution as the Fe2+ (not Fe3+) ions at room temperature and at temperature 100oC, copper dissolved into NaCl solution as the Cu+ ions at room temperature and as the Cu+ and the Cu2+ ions at temperature 100oC. It is founded experimentally that copper corrosion is higher than aluminium corrosion, and ratio of electrochemical corrosion rates, kCu/kAl>1, decreases with temperature increasing, although iron electrochemical corrosion rate doesn’t depend on temperature below 100oC. It is obvious, because melting point of iron is more higher then melting point of copper or aluminium. It is calculated that copper electrochemical corrosion rate is approximately equal to aluminium electrochemical corrosion at temperature about 300oC, so copper can dissolve into NaCl solution mostly as the Cu2+ ions at temperature about 300oC. Ratio of intrinsic diffusivities, DCu/DAl <1, increases with temperature increasing, and intrinsic diffusivity of aluminium could be approximately equal to intrinsic diffusivity of copper at temperature about 460oC.
Title: Copper, Iron, and Aluminium Electrochemical Corrosion Rates and Intrinsic Diffusivitives Dependence on Temperature Investigations
Description:
Our investigations show that electrochemical corrosion of copper is faster than electrochemical corrosion of aluminium at temperatures below 100oC.
Literature data analysis shows that the Al atoms diffuse faster than the Cu atoms at temperatures higher than 475oC, Al rich intermetallic compounds (IMCs) are formed faster in the Cu-Al system, and the Kirkendall plane shifts toward Al side.
Electrochemical corrosion occurs due to electric current and due to diffusion.
An electronic devise working time, for example, depends on initial copper cover thickness on aluminium wire, connected to the electronic devise, temperature, and volume and dislocation pipe diffusion coefficients, so copper, iron, and aluminium electrochemical corrosion rates are investigated experimentally at room temperature and at temperature 100oC.
Intrinsic diffusivities ratios of copper and aluminium at different temperatures and diffusion activation energies in the Cu-Al system are calculated by proposed here methods using literature experimental data.
Dislocation pipe and volume diffusion activation energies of pure iron are calculated separately by earlier proposed method using literature experimental data.
Aluminium dissolved into NaCl solution as the Al3+ ions at room temperature and at temperature 100oC, iron dissolved into NaCl solution as the Fe2+ (not Fe3+) ions at room temperature and at temperature 100oC, copper dissolved into NaCl solution as the Cu+ ions at room temperature and as the Cu+ and the Cu2+ ions at temperature 100oC.
It is founded experimentally that copper corrosion is higher than aluminium corrosion, and ratio of electrochemical corrosion rates, kCu/kAl>1, decreases with temperature increasing, although iron electrochemical corrosion rate doesn’t depend on temperature below 100oC.
It is obvious, because melting point of iron is more higher then melting point of copper or aluminium.
It is calculated that copper electrochemical corrosion rate is approximately equal to aluminium electrochemical corrosion at temperature about 300oC, so copper can dissolve into NaCl solution mostly as the Cu2+ ions at temperature about 300oC.
Ratio of intrinsic diffusivities, DCu/DAl <1, increases with temperature increasing, and intrinsic diffusivity of aluminium could be approximately equal to intrinsic diffusivity of copper at temperature about 460oC.

Related Results

Copper, Iron, and Aluminium Electrochemical Corrosion Rate Dependence on Temperature
Copper, Iron, and Aluminium Electrochemical Corrosion Rate Dependence on Temperature
Our investigations show that electrochemical corrosion of copper is faster than electrochemical corrosion of aluminium at temperatures below 100°C. Literature data analysis shows t...
Corrosion Of Copper-Base Alloys In A Geothermal Brine
Corrosion Of Copper-Base Alloys In A Geothermal Brine
Abstract The geothermal environment and the experimental procedures and schedules for corrosion tests of copper-base procedures and schedules for corrosion tests ...
Iron stress affects the survival of Toxoplasma gondii
Iron stress affects the survival of Toxoplasma gondii
Abstract Background Iron possesses redox abilities and plays a crucial role in in biosynthesis, energy metabolism, and other biological processes. It represents an indispe...
Sintesis dan Karakteristik Aluminium Sulfat dari Limbah Foil Blister Obat
Sintesis dan Karakteristik Aluminium Sulfat dari Limbah Foil Blister Obat
Limbah foil blister obat merupakan salah satu bahan yang umumnya hanya menjadi sampah bagi masyarakat, padahal limbah aluminium jika berada bebas di lingkungan membutuhkan waktu le...
Evaluating Corrosion Inhibitors For Sour Gas Subsea Pipelines
Evaluating Corrosion Inhibitors For Sour Gas Subsea Pipelines
Abstract Using subsea carbon steel pipelines to transport wet sour gas possesses huge challenges to the operators to maintain the high level of the Assets and Ope...
Spectral Analysis Of CO2 Corrosion Product Scales On 13Cr Tubing Steel
Spectral Analysis Of CO2 Corrosion Product Scales On 13Cr Tubing Steel
Abstract CO2 corrosion product scales formed on 13Cr tubing steel in autoclave and in the simulated corrosion environment of oil field are investigated in the pap...
(Invited) Rust Design for Corrosion Protection of Steel Exposed to Atmospheric and Marine Environments
(Invited) Rust Design for Corrosion Protection of Steel Exposed to Atmospheric and Marine Environments
Steel materials have been used in many fields as basic materials for infrastructures due to their superior strength and toughness. However, steel is significantly more susceptible ...
Addition of Alloying Agents to Improve the Performance of Zn/Al Metallic Coated Steel
Addition of Alloying Agents to Improve the Performance of Zn/Al Metallic Coated Steel
This work set out to investigate the microstructural changes and corrosion mechanisms of several zinc-based sacrificial metallic coatings which are used within the strip steel indu...

Back to Top