Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

A Numerical Study on Sweeping Mist Jet Impingement Cooling

View through CrossRef
Abstract This paper presents a 2-D numerical study to investigate the fluid flow behavior and cooling characteristics caused by injecting tiny droplets into the sweeping air jet through a fluidic oscillator. An unsteady Reynolds-averaged Navier-Stokes (URANS) simulation accompanied with the k-ω SST turbulence model is used in this study. The movement and evaporation of the mist are simulated by using the discrete phase model (DPM). The study has been conducted for a target wall with a constant heat flux of 3,000 W/m2, jet-to-wall distance of 4, ReD = 2,500, and a mist /air mass ratio of 5% with a droplet size of 5 microns. A comparison between the cooling performance of steady and sweeping jets is presented for two impingement schemes (i.e., confined and unconfined impingement). The approach of using a slip upper wall boundary condition as an alternative of the unconfined impingement scheme is investigated as well. The results show that adding mist provided a temperature reduction of 5–10% on the target wall in all cases when compared to the air cases. Mist mostly follows the air jet behavior in both steady and sweeping jets in both impingement schemes. The liquid droplet coalescence phenomenon prevails in the sweeping jet case, while it is not as significant in the steady jet case. For the confined impingement, both mist jets provided the similar average temperature reduction. However, the steady mist jet introduced a 58% more target wall shear compared to the sweeping mist jet. For the unconfined impingement, the steady mist jet achieved a better average cooling performance compared to that of the sweeping mist jet. However, the steady mist jet introduced a 72% more target wall shear compared to the sweeping mist jet. Using a slip upper wall boundary condition to reduce the computational time resulted in similar average heat transfer distribution on the target wall to the unconfined case. However, the flow pattern, vortical structures, and droplet dynamics were very different.
Title: A Numerical Study on Sweeping Mist Jet Impingement Cooling
Description:
Abstract This paper presents a 2-D numerical study to investigate the fluid flow behavior and cooling characteristics caused by injecting tiny droplets into the sweeping air jet through a fluidic oscillator.
An unsteady Reynolds-averaged Navier-Stokes (URANS) simulation accompanied with the k-ω SST turbulence model is used in this study.
The movement and evaporation of the mist are simulated by using the discrete phase model (DPM).
The study has been conducted for a target wall with a constant heat flux of 3,000 W/m2, jet-to-wall distance of 4, ReD = 2,500, and a mist /air mass ratio of 5% with a droplet size of 5 microns.
A comparison between the cooling performance of steady and sweeping jets is presented for two impingement schemes (i.
e.
, confined and unconfined impingement).
The approach of using a slip upper wall boundary condition as an alternative of the unconfined impingement scheme is investigated as well.
The results show that adding mist provided a temperature reduction of 5–10% on the target wall in all cases when compared to the air cases.
Mist mostly follows the air jet behavior in both steady and sweeping jets in both impingement schemes.
The liquid droplet coalescence phenomenon prevails in the sweeping jet case, while it is not as significant in the steady jet case.
For the confined impingement, both mist jets provided the similar average temperature reduction.
However, the steady mist jet introduced a 58% more target wall shear compared to the sweeping mist jet.
For the unconfined impingement, the steady mist jet achieved a better average cooling performance compared to that of the sweeping mist jet.
However, the steady mist jet introduced a 72% more target wall shear compared to the sweeping mist jet.
Using a slip upper wall boundary condition to reduce the computational time resulted in similar average heat transfer distribution on the target wall to the unconfined case.
However, the flow pattern, vortical structures, and droplet dynamics were very different.

Related Results

Impingement/Effusion Cooling With Low Coolant Mass Flow
Impingement/Effusion Cooling With Low Coolant Mass Flow
A low coolant mass flow impingement/effusion design for a low NOx combustor wall cooling application was predicted, using conjugate heat transfer (CHT) computational fluid dynamics...
Conjugate Heat Transfer Characteristics of a Film-Cooled Turbine Blade Leading Edge With Staggered-Oblique Impinging Jets
Conjugate Heat Transfer Characteristics of a Film-Cooled Turbine Blade Leading Edge With Staggered-Oblique Impinging Jets
Abstract The turbine blade leading edge is subjected to harsh conditions due to high heat loads and unfavorable compact structures. To improve the cooling performanc...
Pressure Losses for Jet Array Impingement With Crossflow
Pressure Losses for Jet Array Impingement With Crossflow
Jet impingement is an efficient heat transfer method and has been used successfully in cooling of turbine blades in gas turbine engines. Although many studies have been conducted o...
Heat Transfer Enhancement in Tubular Heat Exchanger with Jet Impingement: A Review
Heat Transfer Enhancement in Tubular Heat Exchanger with Jet Impingement: A Review
Heat exchanger (HE) is a thermal device used to transfer heat from higher fluid temperatures to lower fluid temperatures. There is an increasing need to increase the efficiency of ...
Cavitation in Submerged Water Jet at High Jet Pressure
Cavitation in Submerged Water Jet at High Jet Pressure
Recent industrial applications have unfolded a promising prospect for submerged water jet. Apart from widely acknowledged water jet properties, submerged water jet is characterized...
Numerical Investigation of an Integrated Impingement and Pin-Fin Cooling Configuration in a Wedge Duct
Numerical Investigation of an Integrated Impingement and Pin-Fin Cooling Configuration in a Wedge Duct
In the gas turbine blade cooling design, impingement insert and pin-fins arranged as an array in the trailing region are usually used to enhance the heat transfer. To investigate t...