C56 ACCURACY OF TWO–DIMENSIONAL SPECKLE TRACKING PARAMETERS REFLECTING LEFT ATRIAL FUNCTION IN PREDICTING OUTCOME AMONG OUTPATIENTS AFFECTED BY HEART FAILURE

View through CrossRef
Abstract Background The two–dimensional speckle tracking analysis (2D–ST) is a new useful tool in order to evaluate both atrial and ventricular function. Aim of the study. To evaluate the accuracy of the 2D–ST measures reflecting atrial and ventricular function in predicting the outcome among outpatients affected by chronic heart failure (CHF). Methods We enrolled 212 outpatients (age 64±13 years, 77% males, mean left ventricular ejection fraction, LVEF, 38±11%, NYHA class 2.4±0.5) affected by CHF in conventional therapy (sacubitril/valsartan or ACE–inhibitors or Angiotensin II receptor blockers in 85%, beta–blockers in 94%, mineralcorticoid receptor antagonists in 74%, diuretics in 72%, SGLT2 inhibitors in 20%). All patients underwent a medical visit, an ECG and an echocardiographic examination. The following 2D–ST parameters reflecting atrial and ventricular function were analyzed: global longitudinal left ventricular strain (LV–GLS, mean –11.4±3.9%), global longitudinal right ventricular strain (RV–GLS, mean –15.2±5.2%), free wall right ventricular longitudinal strain (RV–fwLS, mean –20.2±5.8%); left atrial reservoir (LAr, mean 19±10.8%), conduit (LAcd, mean –10.–8±6.8) and contraction (LAct, mean –8.1±8.2). Moreover, the early diastolic peak at pulsed Doppler (E) and at the level of septal (e’s) and lateral (e’l) mitral annulus by Tissue Doppler Imaging (TDI) were also evaluated. Then the ratio between E and e’s (E/es, mean 13.9±6.4) and between E and the mean of e’s and e’l (E/em, mean 11.1±5.4) were also calculated. Finally, the ratio between LAr and E/es (LAr/Ees, mean 1.98±1.65) and E/em (LAr/Eem, mean 2.51±1.95) were computed. During follow–up the progression of heart failure, defined as heart failure hospitalization or cardiovascular death, were evaluated. Results During a mean follow–up of 13±6, 32 patients experienced death (13) and/or hospitalization (25) for heart failure worsening. The table shows the relationship among echocardiographic variables and outcome At Cox univariate regression analysis and the relative C–index. LAR/Ees showed the greater accuracy (C–index) in predicting heart failure progression. Conclusions 2D–ST is an echocardiographic approach able to more accurately assess both left ventricular and atrial function. In our series, among the 2D–ST parameters, the ratio between LAr and E/es is characterized by the greater accuracy in predicting heart failure progression.
Title: C56 ACCURACY OF TWO–DIMENSIONAL SPECKLE TRACKING PARAMETERS REFLECTING LEFT ATRIAL FUNCTION IN PREDICTING OUTCOME AMONG OUTPATIENTS AFFECTED BY HEART FAILURE
Description:
Abstract Background The two–dimensional speckle tracking analysis (2D–ST) is a new useful tool in order to evaluate both atrial and ventricular function.
Aim of the study.
To evaluate the accuracy of the 2D–ST measures reflecting atrial and ventricular function in predicting the outcome among outpatients affected by chronic heart failure (CHF).
Methods We enrolled 212 outpatients (age 64±13 years, 77% males, mean left ventricular ejection fraction, LVEF, 38±11%, NYHA class 2.
4±0.
5) affected by CHF in conventional therapy (sacubitril/valsartan or ACE–inhibitors or Angiotensin II receptor blockers in 85%, beta–blockers in 94%, mineralcorticoid receptor antagonists in 74%, diuretics in 72%, SGLT2 inhibitors in 20%).
All patients underwent a medical visit, an ECG and an echocardiographic examination.
The following 2D–ST parameters reflecting atrial and ventricular function were analyzed: global longitudinal left ventricular strain (LV–GLS, mean –11.
4±3.
9%), global longitudinal right ventricular strain (RV–GLS, mean –15.
2±5.
2%), free wall right ventricular longitudinal strain (RV–fwLS, mean –20.
2±5.
8%); left atrial reservoir (LAr, mean 19±10.
8%), conduit (LAcd, mean –10.
–8±6.
8) and contraction (LAct, mean –8.
1±8.
2).
Moreover, the early diastolic peak at pulsed Doppler (E) and at the level of septal (e’s) and lateral (e’l) mitral annulus by Tissue Doppler Imaging (TDI) were also evaluated.
Then the ratio between E and e’s (E/es, mean 13.
9±6.
4) and between E and the mean of e’s and e’l (E/em, mean 11.
1±5.
4) were also calculated.
Finally, the ratio between LAr and E/es (LAr/Ees, mean 1.
98±1.
65) and E/em (LAr/Eem, mean 2.
51±1.
95) were computed.
During follow–up the progression of heart failure, defined as heart failure hospitalization or cardiovascular death, were evaluated.
Results During a mean follow–up of 13±6, 32 patients experienced death (13) and/or hospitalization (25) for heart failure worsening.
The table shows the relationship among echocardiographic variables and outcome At Cox univariate regression analysis and the relative C–index.
LAR/Ees showed the greater accuracy (C–index) in predicting heart failure progression.
Conclusions 2D–ST is an echocardiographic approach able to more accurately assess both left ventricular and atrial function.
In our series, among the 2D–ST parameters, the ratio between LAr and E/es is characterized by the greater accuracy in predicting heart failure progression.

Related Results

Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct Introduction Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Frequency of Common Chromosomal Abnormalities in Patients with Idiopathic Acquired Aplastic Anemia
Objective: To determine the frequency of common chromosomal aberrations in local population idiopathic determine the frequency of common chromosomal aberrations in local population...
Left atrial function assessment by speckle tracking echocardiography in low-risk atrial fibrillation patients
Left atrial function assessment by speckle tracking echocardiography in low-risk atrial fibrillation patients
Objective: To compare the left atrial function utilising speckle tracking echocardiography in patients with low-risk and high-risk non-valvular atrial fibrillation.Methods: The des...
Left atrial appendage anatomy and function: short term response to sustained atrial fibrillation
Left atrial appendage anatomy and function: short term response to sustained atrial fibrillation
OBJECTIVE To determine whether there is significant atrial or atrial appendage enlargement or functional remodelling as a result of one to two months of sustained...
Left atrial strain parameters are able to predict presence of atrial fibrillation
Left atrial strain parameters are able to predict presence of atrial fibrillation
Abstract Background Three-dimensional speckle-tracking echocardiography allows evaluation of left atrial function, left atrial f...
Etiology and predictors of heart failure in pregnancy. Newer Insights from the M-PAC registry
Etiology and predictors of heart failure in pregnancy. Newer Insights from the M-PAC registry
Abstract Background Women with heart disease undergoing pregnancy is on the increase, along with an increasing cardiac contribut...

Back to Top