Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Design criteria for diagrid tall buildings: Stiffness versus strength

View through CrossRef
SUMMARYThe procedures and formulations suggested in literature for the design of diagrid structures start from the assumption that diagonal sizing process is governed by the stiffness requirements, as usually occurs for other, less efficient, structural types, and that member strength demand is automatically satisfied by the cross section resulting from the stiffness requirements. However, thanks to the high rigidity of the diagonalized façade, strength requirements can be of paramount importance and even be the governing design criterion. In this paper, stiffness and strength design criteria for diagrid structures are examined and translated in simplified formulae for quick member sizing. The application of the two approaches for the design of a 100‐storey building model, carried out for different diagrid geometrical patterns, gives the opportunity of discussing the relative influence of stiffness and strength on the design outcomes, in terms of resulting diagonal cross sections and steel weight, as well as on the structural performance. Copyright © 2013 John Wiley & Sons, Ltd.
Title: Design criteria for diagrid tall buildings: Stiffness versus strength
Description:
SUMMARYThe procedures and formulations suggested in literature for the design of diagrid structures start from the assumption that diagonal sizing process is governed by the stiffness requirements, as usually occurs for other, less efficient, structural types, and that member strength demand is automatically satisfied by the cross section resulting from the stiffness requirements.
However, thanks to the high rigidity of the diagonalized façade, strength requirements can be of paramount importance and even be the governing design criterion.
In this paper, stiffness and strength design criteria for diagrid structures are examined and translated in simplified formulae for quick member sizing.
The application of the two approaches for the design of a 100‐storey building model, carried out for different diagrid geometrical patterns, gives the opportunity of discussing the relative influence of stiffness and strength on the design outcomes, in terms of resulting diagonal cross sections and steel weight, as well as on the structural performance.
Copyright © 2013 John Wiley & Sons, Ltd.

Related Results

Effect of Aspect Ratio on High Rise Structures with Diagrid
Effect of Aspect Ratio on High Rise Structures with Diagrid
Urbanization and population explosion in the present times has led to increase in demand for land and residencies but the availability of land is scare i.e reason a trend has evolv...
Design
Design
Conventional definitions of design rarely capture its reach into our everyday lives. The Design Council, for example, estimates that more than 2.5 million people use design-related...
Livability of High-Rise Districts - Case Study of West Bay in Doha
Livability of High-Rise Districts - Case Study of West Bay in Doha
Doha, the capital of the state of Qatar, is a small Gulf city that grew as a port settlement on pearling and fishing activities. Since the mid-seventies, Doha has begun the process...
Reliability-based design (RBD) of shallow foundations on rock masses
Reliability-based design (RBD) of shallow foundations on rock masses
[ACCESS RESTRICTED TO THE UNIVERSITY OF MISSOURI AT AUTHOR'S REQUEST.] The reliability-based design (RBD) approach that separately accounts for variability and uncertainty in load(...
Decarbonizing Tall Building Structures: Implementing Machine Learning At The Early-stage Of Design Process
Decarbonizing Tall Building Structures: Implementing Machine Learning At The Early-stage Of Design Process
The construction of tall buildings generates a high spatial and temporal concentration of greenhouse gas (GHG) emissions. Research studies have shown that as building height increa...
Stiffness regulation by reflex action in the normal human hand
Stiffness regulation by reflex action in the normal human hand
1. The torque and electromyographic (EMG) responses to stretch of the first dorsal interosseous muscle (externally imposed joint rotation) were recorded in five normal human subjec...
Abstract 1099: Mapping matrix mechanics in 3D to study the role of stiffness in breast tumor progression.
Abstract 1099: Mapping matrix mechanics in 3D to study the role of stiffness in breast tumor progression.
Abstract Introduction Evidence suggests that the Extra Cellular Matrix (ECM) stiffness may be a driving factor in tumor progression and may sensitize ...

Back to Top