Beam Emittance and Bunch Length Diagnostics for the MIR-FEL Beamline at Chiang Mai University

View through CrossRef
The generation of high-quality mid-infrared free-electron laser (MIR-FEL) radiation depends critically on precise control of electron beam parameters, including energy, energy spread, transverse emittance, bunch charge, and bunch length. At the PBP-CMU Electron Linac Laboratory (PCELL), effective beam diagnostics are essential for optimizing FEL performance. However, dedicated systems for direct measurement of transverse emittance and bunch length at the undulator entrance have been lacking. This paper addresses this gap by presenting the design, simulation, and analysis of diagnostic stations for accurate characterization of these parameters. A two-quadrupole emittance measurement system was developed, enabling independent control of beam-focusing in both transverse planes. An analytical model was formulated specifically for this configuration to enhance emittance reconstruction accuracy. Systematic error analysis was conducted using ASTRA beam dynamics simulations, incorporating 3D field maps from CST Studio Suite and fully including space-charge effects. Results show that transverse emittance values as low as 0.15 mm·mrad can be measured with less than 20% error when the initial RMS beam size is under 2 mm. Additionally, quadrupole misalignment effects were quantified, showing that alignment within ±0.95 mm limits systematic errors to below 33.3%. For bunch length measurements, a transition radiation (TR) station coupled with a Michelson interferometer was designed. Spectral and interferometric simulations reveal that transverse beam size and beam splitter properties significantly affect measurement accuracy. A 6% error due to transverse size was identified, while Kapton beam splitters introduced additional systematic distortions. In contrast, a 6 mm-thick silicon beam splitter enabled accurate, correction-free measurements. The finite size of the radiator was also found to suppress low-frequency components, resulting in up to 10.6% underestimation of bunch length. This work provides a practical and comprehensive diagnostic framework that accounts for multiple error sources in both transverse emittance and bunch length measurements. These findings contribute valuable insight for the beam diagnostics community and support improved control of beam quality in MIR FEL systems.
Title: Beam Emittance and Bunch Length Diagnostics for the MIR-FEL Beamline at Chiang Mai University
Description:
The generation of high-quality mid-infrared free-electron laser (MIR-FEL) radiation depends critically on precise control of electron beam parameters, including energy, energy spread, transverse emittance, bunch charge, and bunch length.
At the PBP-CMU Electron Linac Laboratory (PCELL), effective beam diagnostics are essential for optimizing FEL performance.
However, dedicated systems for direct measurement of transverse emittance and bunch length at the undulator entrance have been lacking.
This paper addresses this gap by presenting the design, simulation, and analysis of diagnostic stations for accurate characterization of these parameters.
A two-quadrupole emittance measurement system was developed, enabling independent control of beam-focusing in both transverse planes.
An analytical model was formulated specifically for this configuration to enhance emittance reconstruction accuracy.
Systematic error analysis was conducted using ASTRA beam dynamics simulations, incorporating 3D field maps from CST Studio Suite and fully including space-charge effects.
Results show that transverse emittance values as low as 0.
15 mm·mrad can be measured with less than 20% error when the initial RMS beam size is under 2 mm.
Additionally, quadrupole misalignment effects were quantified, showing that alignment within ±0.
95 mm limits systematic errors to below 33.
3%.
For bunch length measurements, a transition radiation (TR) station coupled with a Michelson interferometer was designed.
Spectral and interferometric simulations reveal that transverse beam size and beam splitter properties significantly affect measurement accuracy.
A 6% error due to transverse size was identified, while Kapton beam splitters introduced additional systematic distortions.
In contrast, a 6 mm-thick silicon beam splitter enabled accurate, correction-free measurements.
The finite size of the radiator was also found to suppress low-frequency components, resulting in up to 10.
6% underestimation of bunch length.
This work provides a practical and comprehensive diagnostic framework that accounts for multiple error sources in both transverse emittance and bunch length measurements.
These findings contribute valuable insight for the beam diagnostics community and support improved control of beam quality in MIR FEL systems.

Related Results

Deranged MicroRNA 16-2 Expression Contributes to Erythropoiesis in Polycythemia Vera.
Deranged MicroRNA 16-2 Expression Contributes to Erythropoiesis in Polycythemia Vera.
Abstract Abstract 3896 Poster Board III-832 We previously reported the finding of significantly raised levels of mature microRNA 16 (mi...
MicroRNAs Expression Profile in Young Patients with Acute Myocardial Infarction
MicroRNAs Expression Profile in Young Patients with Acute Myocardial Infarction
Introduction: Acute myocardial infarction (AMI) is a severe coronary heart disease.   Targeted miRNAs studies implicated two main pathways in the regulation of AMI namely pro-apopt...
Directional emittance of dry and moist paper
Directional emittance of dry and moist paper
Abstract The directional emittance of dry and moist paper and board samples was measured in two wavelength ranges; the mid-wavelength infrared (MWIR) range and the l...

Back to Top