Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Comparison of the Josephson Voltage Standards of the NIMT and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b)

View through CrossRef
A comparison of the Josephson array voltage standards of the Bureau International des Poids et Mesures (BIPM) and the National Institute of Metrology - (Thailand), NIMT, was carried out in November 2015 at the level of 10 V. For this exercise, options A and B of the BIPM.EM-K10.b comparison protocol were applied. Option B required the BIPM to provide a reference voltage for measurement by the NIMT using its Josephson standard with its own measuring device. Option A required the NIMT to provide a reference voltage with its Josephson voltage standard for measurement by the BIPM using an analogue nanovoltmeter and associated measurement loop. In all cases the BIPM array was kept floating from ground. The final results were in good agreement within the combined relative standard uncertainty of 2.6 parts in 1010 for the nominal voltage of 10 V. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Title: Comparison of the Josephson Voltage Standards of the NIMT and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b)
Description:
A comparison of the Josephson array voltage standards of the Bureau International des Poids et Mesures (BIPM) and the National Institute of Metrology - (Thailand), NIMT, was carried out in November 2015 at the level of 10 V.
For this exercise, options A and B of the BIPM.
EM-K10.
b comparison protocol were applied.
Option B required the BIPM to provide a reference voltage for measurement by the NIMT using its Josephson standard with its own measuring device.
Option A required the NIMT to provide a reference voltage with its Josephson voltage standard for measurement by the BIPM using an analogue nanovoltmeter and associated measurement loop.
In all cases the BIPM array was kept floating from ground.
The final results were in good agreement within the combined relative standard uncertainty of 2.
6 parts in 1010 for the nominal voltage of 10 V.
Main text To reach the main text of this paper, click on Final Report.
Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.
bipm.
org/.
The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

Related Results

Bilateral comparison of 10 V standards between the NSAI - NML (Ireland) and the BIPM (BIPM.EM-K11.b)
Bilateral comparison of 10 V standards between the NSAI - NML (Ireland) and the BIPM (BIPM.EM-K11.b)
As part of the ongoing BIPM key comparison BIPM.EM-K11.b, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Authority of Ireland - Nationa...
BIPM.EM-K11 comparison of 1.018 V and 10 V Standards between the BEV (Austria) and the BIPM, April to May 2025
BIPM.EM-K11 comparison of 1.018 V and 10 V Standards between the BEV (Austria) and the BIPM, April to May 2025
Main text As part of the ongoing BIPM key comparison BIPM.EM-K11, a comparison of the 1.018 V and 10 V voltage reference standards of the BIPM and the Bundesamt für ...
Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM
Bilateral comparison of 10 V standards between the NSAI-NML (Ireland) and the BIPM
Main text As part of the ongoing BIPM key comparison BIPM.EM-K11, a comparison of the 10 V voltage reference standards of the BIPM and the National Standards Auth...
Bilateral comparison of 1.018 V and 10 V standards between the BIM (Bulgaria) and the BIPM (BIPM.EM-K11.a and b)
Bilateral comparison of 1.018 V and 10 V standards between the BIM (Bulgaria) and the BIPM (BIPM.EM-K11.a and b)
Main text As part of the ongoing BIPM key comparison BIPM.EM-K11.a and b, a comparison of the 1.018 V and 10 V voltage reference standards of the BIPM and the Bul...
Comparison of the Josephson Voltage Standards of the PTB and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b)
Comparison of the Josephson Voltage Standards of the PTB and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b)
A comparison of the Josephson array voltage standards of the Bureau International des Poids et Mesures (BIPM) and the Physikalisch-Technische Bundesanstalt (PTB), Braunschweig, Ger...
Comparison of the Josephson voltage standards of the MIKES and the BIPM
Comparison of the Josephson voltage standards of the MIKES and the BIPM
Main text As part of the ongoing BIPM key comparison BIPM.EM-K10.b, a direct comparison of the Josephson array voltage standards of the Bureau International des P...

Back to Top