Comparison of the Josephson Voltage Standards of the NIMT and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b)

View through CrossRef
A comparison of the Josephson array voltage standards of the Bureau International des Poids et Mesures (BIPM) and the National Institute of Metrology - (Thailand), NIMT, was carried out in November 2015 at the level of 10 V. For this exercise, options A and B of the BIPM.EM-K10.b comparison protocol were applied. Option B required the BIPM to provide a reference voltage for measurement by the NIMT using its Josephson standard with its own measuring device. Option A required the NIMT to provide a reference voltage with its Josephson voltage standard for measurement by the BIPM using an analogue nanovoltmeter and associated measurement loop. In all cases the BIPM array was kept floating from ground. The final results were in good agreement within the combined relative standard uncertainty of 2.6 parts in 1010 for the nominal voltage of 10 V. Main text To reach the main text of this paper, click on Final Report. Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.bipm.org/. The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).
Title: Comparison of the Josephson Voltage Standards of the NIMT and the BIPM (part of the ongoing BIPM key comparison BIPM.EM-K10.b)
Description:
A comparison of the Josephson array voltage standards of the Bureau International des Poids et Mesures (BIPM) and the National Institute of Metrology - (Thailand), NIMT, was carried out in November 2015 at the level of 10 V.
For this exercise, options A and B of the BIPM.
EM-K10.
b comparison protocol were applied.
Option B required the BIPM to provide a reference voltage for measurement by the NIMT using its Josephson standard with its own measuring device.
Option A required the NIMT to provide a reference voltage with its Josephson voltage standard for measurement by the BIPM using an analogue nanovoltmeter and associated measurement loop.
In all cases the BIPM array was kept floating from ground.
The final results were in good agreement within the combined relative standard uncertainty of 2.
6 parts in 1010 for the nominal voltage of 10 V.
Main text To reach the main text of this paper, click on Final Report.
Note that this text is that which appears in Appendix B of the BIPM key comparison database kcdb.
bipm.
org/.
The final report has been peer-reviewed and approved for publication by the CCEM, according to the provisions of the CIPM Mutual Recognition Arrangement (CIPM MRA).

Related Results

MoS2/Montmorillonite Nanocomposite: Preparation, Tribological Properties, and Inner Synergistic Lubrication
MoS2/Montmorillonite Nanocomposite: Preparation, Tribological Properties, and Inner Synergistic Lubrication
A nano-MoS2/montmorillonite K-10 (K10) composite was prepared and characterized. The composite contains two types of 2H-MoS2 nanoparticles. One is the hollow spherical MoS2 with a ...
Key comparison BIPM.RI(I)-K2 of the air-kerma standards of the NIM, China, and the BIPM in low-energy x-rays
Key comparison BIPM.RI(I)-K2 of the air-kerma standards of the NIM, China, and the BIPM in low-energy x-rays
A key comparison has been made between the air-kerma standards of the NIM and the BIPM in the low-energy x-ray range. The results show the standards to be in agreement at the level...
Prevalence of Indices of Stress with Degree of Insomnia and Academic Performance in Undergraduate Medical Students
Prevalence of Indices of Stress with Degree of Insomnia and Academic Performance in Undergraduate Medical Students
Background: Studying medicine is quite challenging as medical students have to work hours and hours which leads to continuous psychological stress and as a result decrease in sleep...
Josephson voltage standards as toolkit for precision metrological applications at PTB
Josephson voltage standards as toolkit for precision metrological applications at PTB
Abstract About 60 years after the discovery of the Josephson effect, electrical DC voltage calibrations are routinely performed worldwide—mostly using automated Jose...
API Offshore Structures Standards: Changing Times
API Offshore Structures Standards: Changing Times
Abstract Two instrumental series of events in the past several years have provided the impetus for API Subcommittee 2 (SC 2) to action a new strategy for the API ...
APMP key comparison of DC voltage at 1.018 V and 10 V
APMP key comparison of DC voltage at 1.018 V and 10 V
A key comparison of DC voltage at 1.018 V and 10 V has been conducted from 2009 to 2011 between APMP member laboratories and the BIPM. All participants' results (except one) are wi...
Design and Simulation Converter with Buck-boost Converter as The Voltage Stabilizer
Design and Simulation Converter with Buck-boost Converter as The Voltage Stabilizer
Buck-boost Converter is the device with the function to convert DC Voltage input to the setpoint DC Voltage output. Buck-boost converter can be used for regulating unstable voltage...

Back to Top