Sensitivity of a 29-Channel MEG Source Montage
View through CrossRef
In this paper, we study the performance of a source montage corresponding to 29 brain regions reconstructed from whole-head magnetoencephalographic (MEG) recordings, with the aim of facilitating the review of MEG data containing epileptiform discharges. Test data were obtained by superposing simulated signals from 100-nAm dipolar sources to a resting state MEG recording from a healthy subject. Simulated sources were placed systematically to different cortical locations for defining the optimal regularization for the source montage reconstruction and for assessing the detectability of the source activity from the 29-channel MEG source montage. The signal-to-noise ratio (SNR), computed for each source from the sensor-level and source-montage signals, was used as the evaluation parameter. Without regularization, the SNR from the simulated sources was larger in the sensor-level signals than in the source montage reconstructions. Setting the regularization to 2% increased the source montage SNR to the same level as the sensor-level SNR, improving the detectability of the simulated events from the source montage reconstruction. Sources producing a SNR of at least 15 dB were visually detectable from the source-montage signals. Such sources are located closer than about 75 mm from the MEG sensors, in practice covering all areas in the grey matter. The 29-channel source montage creates more focal signals compared to the sensor space and can significantly shorten the detection time of epileptiform MEG discharges for focus localization.
Title: Sensitivity of a 29-Channel MEG Source Montage
Description:
In this paper, we study the performance of a source montage corresponding to 29 brain regions reconstructed from whole-head magnetoencephalographic (MEG) recordings, with the aim of facilitating the review of MEG data containing epileptiform discharges.
Test data were obtained by superposing simulated signals from 100-nAm dipolar sources to a resting state MEG recording from a healthy subject.
Simulated sources were placed systematically to different cortical locations for defining the optimal regularization for the source montage reconstruction and for assessing the detectability of the source activity from the 29-channel MEG source montage.
The signal-to-noise ratio (SNR), computed for each source from the sensor-level and source-montage signals, was used as the evaluation parameter.
Without regularization, the SNR from the simulated sources was larger in the sensor-level signals than in the source montage reconstructions.
Setting the regularization to 2% increased the source montage SNR to the same level as the sensor-level SNR, improving the detectability of the simulated events from the source montage reconstruction.
Sources producing a SNR of at least 15 dB were visually detectable from the source-montage signals.
Such sources are located closer than about 75 mm from the MEG sensors, in practice covering all areas in the grey matter.
The 29-channel source montage creates more focal signals compared to the sensor space and can significantly shorten the detection time of epileptiform MEG discharges for focus localization.
Related Results
Event-Wise Stability of Patient-Specific EEG-MEG Deep Learning Spike Detection in Clinical MEG
Event-Wise Stability of Patient-Specific EEG-MEG Deep Learning Spike Detection in Clinical MEG
Abstract
Objective
Computational magnetoencephalography (MEG) interictal epileptiform discharge (IED) detectors have mainly use...
En skvatmølle i Ljørring
En skvatmølle i Ljørring
A Horizontal Mill at Ljørring, Jutland.Horizontal water-mills have been in use in Jutland since the beginning of the Christian era 2). But the one here described shows so close a c...
Insights Into Thrombopoiesis From Infused Human Megakaryocytes Into Mice
Insights Into Thrombopoiesis From Infused Human Megakaryocytes Into Mice
Abstract
Thrombopoiesis is the process by which megakaryocytes (Megs) release platelets (Plts), but issues remain as to the detailed in vivo mechanisms underlying th...
Flow Assurance Impacts on Lean/Rich MEG Circuit Chemistry and MEG Regenerator/Reclaimer Design
Flow Assurance Impacts on Lean/Rich MEG Circuit Chemistry and MEG Regenerator/Reclaimer Design
Abstract
The chemistry of the Lean and Rich monoethylene glycol (MEG) closed loop circuits is dictated by decisions made by the flow assurance design team. During...
Biophysical network models of phase-synchronization in MEG resting-state
Biophysical network models of phase-synchronization in MEG resting-state
Abstract
Magnetoencephalography (MEG) is used extensively to study functional connectivity (FC) networks of phase-synchronization, but the relati...
Real Time Online Hydrate Monitoring and Prevention in Offshore Fields
Real Time Online Hydrate Monitoring and Prevention in Offshore Fields
Abstract
Hydrate blockage had caused impeded flow in offshore pipelines and resulted production stoppage and significant economic loss. Hydrate blockages can occur v...
The Effect of Salt-Laden Degraded MEG on Gas Hydrate Inhibition
The Effect of Salt-Laden Degraded MEG on Gas Hydrate Inhibition
Abstract
The formation of gas hydrates in pipelines continues to be a major challenge in gas production. Conventionally, thermodynamic hydrate inhibitors (THIs) are ...
La huella del montaje Aby Warburg; Aldo van Eyck, Jerzy Grotowski : recorridos a partir del Atlas Mnemosyne
La huella del montaje Aby Warburg; Aldo van Eyck, Jerzy Grotowski : recorridos a partir del Atlas Mnemosyne
The thesis consists in constructing an itinerary through three fields "culture of science, architecture, theatre" and three authors Aby Warburg, Aldo van Eyck, Jerzy Grotowski, on ...