Javascript must be enabled to continue!
Trends and Incidence of Reported Events Associated with Ureteral Stents: An Analysis of the Food and Drug Administration's Manufacturer and User Facility Device Experience (MAUDE) Database
View through CrossRef
Abstract
Aim of this study is to summarize medical device reports (MDRs) between 2012 and 2022 relating to ureteral stents within the Manufacturer and User Facility Device Experience (MAUDE) database maintained by The Food and Drug Administration (FDA). The MAUDE database was analyzed for all MDRs relating to each FDA-approved ureteral stent. Event descriptions were reviewed and characterized into specific event types. Outcome measures include specific ureteral stent and reported events as detailed by the MDRs. All data is de-identified and in compliance with the Health Insurance Portability and Accountability Act (HIPAA). Data is presented as number of specific event/total events. Pooled Relative risk was used to compare data. Overall, 2652 reports were retrieved in 10 years and a progressive rise in reported events was recorded (Fig. 1). 831/2652 (31%) were reported as injury while 1810/2652 (68%) as malfunction of the ureteral stent and 4 events of death. The most frequently reported adverse events (AEs) were stent break (627/2652: 23%); material problems (384/2652: 14%); calcification (222/2652: 8%); difficulty to insert, advance or remove the device (155/2652: 6%). Bard stents were associated with most material problems (19%), Resonance stents were associated with most difficulty to insert, advance or remove the device (9%) and calcification (15%) while filiform double pigtail stent set were associated with most breakage reports (56%) when compared to the other stents (PRR > 1, p < 0,05) (Table 1, 2, 3). According to MAUDE database the most frequent complications related to ureteral stents are breakage, material problems, calcification and difficulty to insert, advance or remove the device. As well Resonance ureteral stents seem to be associated with a higher risk of device problems.
Research Square Platform LLC
Title: Trends and Incidence of Reported Events Associated with Ureteral Stents: An Analysis of the Food and Drug Administration's Manufacturer and User Facility Device Experience (MAUDE) Database
Description:
Abstract
Aim of this study is to summarize medical device reports (MDRs) between 2012 and 2022 relating to ureteral stents within the Manufacturer and User Facility Device Experience (MAUDE) database maintained by The Food and Drug Administration (FDA).
The MAUDE database was analyzed for all MDRs relating to each FDA-approved ureteral stent.
Event descriptions were reviewed and characterized into specific event types.
Outcome measures include specific ureteral stent and reported events as detailed by the MDRs.
All data is de-identified and in compliance with the Health Insurance Portability and Accountability Act (HIPAA).
Data is presented as number of specific event/total events.
Pooled Relative risk was used to compare data.
Overall, 2652 reports were retrieved in 10 years and a progressive rise in reported events was recorded (Fig.
1).
831/2652 (31%) were reported as injury while 1810/2652 (68%) as malfunction of the ureteral stent and 4 events of death.
The most frequently reported adverse events (AEs) were stent break (627/2652: 23%); material problems (384/2652: 14%); calcification (222/2652: 8%); difficulty to insert, advance or remove the device (155/2652: 6%).
Bard stents were associated with most material problems (19%), Resonance stents were associated with most difficulty to insert, advance or remove the device (9%) and calcification (15%) while filiform double pigtail stent set were associated with most breakage reports (56%) when compared to the other stents (PRR > 1, p < 0,05) (Table 1, 2, 3).
According to MAUDE database the most frequent complications related to ureteral stents are breakage, material problems, calcification and difficulty to insert, advance or remove the device.
As well Resonance ureteral stents seem to be associated with a higher risk of device problems.
Related Results
3D-printed polymeric bioresorbable stents for cardiovascular applications
3D-printed polymeric bioresorbable stents for cardiovascular applications
(English) Bioresorbable stents (BRS) have been envisioned as a revolution in the treatment of coronary heart disease. Ideally, stents would initially retain sufficient radial stren...
Clinicopathological and etiological characteristics for urinary tract infections in cervical cancer patients with radical surgery with ureteral stents indwelling
Clinicopathological and etiological characteristics for urinary tract infections in cervical cancer patients with radical surgery with ureteral stents indwelling
Abstract
Background: To investigate the clinicopathological and etiological characteristics for urinary tract infections in cervical cancer radical surgery with indwelling ...
Effect of Preoperative Hydronephrosis on Ureteral Stenosis after Flexible Ureteroscopy: A Propensity Scores Matching Analysis
Effect of Preoperative Hydronephrosis on Ureteral Stenosis after Flexible Ureteroscopy: A Propensity Scores Matching Analysis
Abstract
OBJECTIVES: Ureteral stenosis is a serious complication after flexible ureteroscopy. Other studies have confirmed that stone impaction and intraoperative ureteral ...
Primary ureteroscopy for proximal ureteral stones
Primary ureteroscopy for proximal ureteral stones
Abstract
Purpose
Primary Ureteroscopy & Laser Lithotripsy is the treatment of choice for distal ureteral stones. However, in cases of proximal ureteral stones some uro...
Science progress distinguishing different types of airway stents under bronchoscopy by artificial intelligence
Science progress distinguishing different types of airway stents under bronchoscopy by artificial intelligence
Objective
In prior research, we employed artificial intelligence (AI) to distinguish different anatomical positions in the airway under bronchoscopy. We aimed to levera...
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Small Cell Lung Cancer and Tarlatamab: A Meta-Analysis of Clinical Trials
Abstract
Introduction
Tarlatamab is a Delta-like ligand 3 (DLL3) -directed bispecific T-cell engager recently approved for use in patients with advanced small cell lung cancer (SCL...
Selection of Injectable Drug Product Composition using Machine Learning Models (Preprint)
Selection of Injectable Drug Product Composition using Machine Learning Models (Preprint)
BACKGROUND
As of July 2020, a Web of Science search of “machine learning (ML)” nested within the search of “pharmacokinetics or pharmacodynamics” yielded over 100...
Analysis Of Medical Device Product Recalls: Insights From The MAUDE Database
Analysis Of Medical Device Product Recalls: Insights From The MAUDE Database
Background: Medical device recalls are crucial for patient safety, and analysing patterns and causes is key to improving device safety and regulations. The MAUDE database, maintain...

