Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

Comparison of Optimized and Conventional Models of Passive Solar Greenhouse—Case Study: The Indoor Air Temperature, Irradiation, and Energy Demand

View through CrossRef
This study was carried out to optimize a computational model of a new underground passive solar greenhouse to improve thermal performance, storage, and saving of heat solar energy. Optimized and conventional passive solar greenhouse were compared in regards of indoor air temperature, irradiation, and energy demand. Six different materials were used in the conventional model. In addition, TRNSYS software was employed to determine heat demand and irradiation in the greenhouse. The results showed that the annual total heating requirement in the optimized model was 30% lower than a conventional passive solar system. In addition, the resulting average air temperature in the optimized model ranged from −4 to 33.1 °C in the four days of cloud, snow, and sun. The average air temperature in the conventional passive solar greenhouse ranged from −8.4 to 24.7 °C. The maximum monthly heating requirement was 796 MJ/m2 for the Wtype87 model (100-mm lightweight concrete block) and the minimum value was 190 MJ/m2 for the Wtype45 model (50-mm insulation with 200-mm clay tile) in a conventional passive solar greenhouse while the monthly heating requirement estimated 126 MJ/m2 for the optimized greenhouse model. The predictability of the TRNSYS model was calculated with a coefficient of determination (R2) of 95.95%.
Title: Comparison of Optimized and Conventional Models of Passive Solar Greenhouse—Case Study: The Indoor Air Temperature, Irradiation, and Energy Demand
Description:
This study was carried out to optimize a computational model of a new underground passive solar greenhouse to improve thermal performance, storage, and saving of heat solar energy.
Optimized and conventional passive solar greenhouse were compared in regards of indoor air temperature, irradiation, and energy demand.
Six different materials were used in the conventional model.
In addition, TRNSYS software was employed to determine heat demand and irradiation in the greenhouse.
The results showed that the annual total heating requirement in the optimized model was 30% lower than a conventional passive solar system.
In addition, the resulting average air temperature in the optimized model ranged from −4 to 33.
1 °C in the four days of cloud, snow, and sun.
The average air temperature in the conventional passive solar greenhouse ranged from −8.
4 to 24.
7 °C.
The maximum monthly heating requirement was 796 MJ/m2 for the Wtype87 model (100-mm lightweight concrete block) and the minimum value was 190 MJ/m2 for the Wtype45 model (50-mm insulation with 200-mm clay tile) in a conventional passive solar greenhouse while the monthly heating requirement estimated 126 MJ/m2 for the optimized greenhouse model.
The predictability of the TRNSYS model was calculated with a coefficient of determination (R2) of 95.
95%.

Related Results

Hydatid Disease of The Brain Parenchyma: A Systematic Review
Hydatid Disease of The Brain Parenchyma: A Systematic Review
Abstarct Introduction Isolated brain hydatid disease (BHD) is an extremely rare form of echinococcosis. A prompt and timely diagnosis is a crucial step in disease management. This ...
Unravelling indoor temperature response to summer heat through long-term crowdsourced observations in Dutch residences
Unravelling indoor temperature response to summer heat through long-term crowdsourced observations in Dutch residences
City dwellers are increasingly exposed to summer heat due to climate change and urbanization. Summer heat, which causes heat stress, is intensified especially at night in urban are...
Solar Trackers Using Six-Bar Linkages
Solar Trackers Using Six-Bar Linkages
Abstract A solar panel faces the sun or has the solar ray normal to its face to enhance power reaping. A fixed solar panel can only meet this condition at one moment...
Solar wind interaction with comet 67P around perihelion
Solar wind interaction with comet 67P around perihelion
AbstractNear perihelion, when comet 67P was most active, the Rosetta spacecraft resided inside the comet induced magnetosphere. The solar wind magnetic field was still present, but...
Study of Solar Combined Air Energy Greenhouse Heating System Model
Study of Solar Combined Air Energy Greenhouse Heating System Model
At present, it is difficult to bring centralized heating to rural areas owing to factors such as scattered distribution, distance from towns and cities, and difficulty in laying pu...
Post-Irradiation Fracture Toughness Characterization of Generation II FeCrAl Alloys
Post-Irradiation Fracture Toughness Characterization of Generation II FeCrAl Alloys
Abstract FeCrAl alloys are promising candidate materials for the accident tolerant fuel (ATF) cladding application due to their exceptional resistance to oxidation i...
Removal of toxic vapors by oxidation: Development of laboratory test procedures for in-duct air cleaning systems
Removal of toxic vapors by oxidation: Development of laboratory test procedures for in-duct air cleaning systems
Exposure to volatile organic compounds (VOC) in workplaces can cause acute effects such as irritation of the skin, the eyes, the mouth, and the nose. Some products may also cause c...
A Hybrid Experimental Modelling Approach to Solar Photovoltaic Cell Temperature Prediction
A Hybrid Experimental Modelling Approach to Solar Photovoltaic Cell Temperature Prediction
Solar cell temperature is critical in the determination of solar energy generated by a solar photovoltaic power plant. High temperatures are associated with a reduction in the ener...

Back to Top