Javascript must be enabled to continue!
18F-NaF PET/CT in Presumed Aseptic Pseudarthrosis after Spinal Fusion: Correlation with Findings at Revision Surgery and Intraoperative Cultures
View through CrossRef
Abstract
Background Conventional imaging is useful to assess interbody fusion by showing complete trabecular bony bridging, but has a low positive predictive value for pseudarthrosis. Because alterations of bone metabolism may precede structural anatomical changes on computed tomography (CT), we aimed to investigate the ability of fluorine 18 sodium fluoride positron emission tomography/computed tomography (18F-NaF PET/CT) to identify pseudarthrosis after spinal fusion using surgical revision as the reference standard.
Methods We retrospectively reviewed 18F-NaF PET/CT scans performed between February 2019 and September 2020 in patients experiencing pain after spinal fusion. We included the 18 patients who underwent revision surgery for suspicion of pseudarthrosis. Five consecutive patients who were clearly fused on CT served as the control group.
Results In the revision surgery group (n=18), visual assessment by 18F-NaF PET/CT revealed that all 22 cages with an increased 18F-NaF uptake around intercorporal fusion material had mobility at revision surgery, whereas none of the fused patients (n=5) showed uptake around cage/intervertebral disk space. Among the 18 patients with presumed aseptic pseudarthrosis, intraoperative cultures revealed surgical site infection (SSI) caused by Cutibacterium acnes (C. acnes) in seven patients (38.9%). There was a statistically significant difference in standardized uptake values and uptake ratios between the revision surgery and control groups (p=5.3× 10−6 and p=0.0002, respectively).
Conclusions 18F-NaF PET/CT imaging appeared as a useful tool to identify pseudarthrosis following spinal fusion. The unexpectedly high prevalence (38.9%) of SSI caused by C. acnes found in presumed aseptic patients supports the utility of intraoperative cultures in revision cases for pseudarthrosis, even without preoperative clinical suspicion of SSI.
Title: 18F-NaF PET/CT in Presumed Aseptic Pseudarthrosis after Spinal Fusion: Correlation with Findings at Revision Surgery and Intraoperative Cultures
Description:
Abstract
Background Conventional imaging is useful to assess interbody fusion by showing complete trabecular bony bridging, but has a low positive predictive value for pseudarthrosis.
Because alterations of bone metabolism may precede structural anatomical changes on computed tomography (CT), we aimed to investigate the ability of fluorine 18 sodium fluoride positron emission tomography/computed tomography (18F-NaF PET/CT) to identify pseudarthrosis after spinal fusion using surgical revision as the reference standard.
Methods We retrospectively reviewed 18F-NaF PET/CT scans performed between February 2019 and September 2020 in patients experiencing pain after spinal fusion.
We included the 18 patients who underwent revision surgery for suspicion of pseudarthrosis.
Five consecutive patients who were clearly fused on CT served as the control group.
Results In the revision surgery group (n=18), visual assessment by 18F-NaF PET/CT revealed that all 22 cages with an increased 18F-NaF uptake around intercorporal fusion material had mobility at revision surgery, whereas none of the fused patients (n=5) showed uptake around cage/intervertebral disk space.
Among the 18 patients with presumed aseptic pseudarthrosis, intraoperative cultures revealed surgical site infection (SSI) caused by Cutibacterium acnes (C.
acnes) in seven patients (38.
9%).
There was a statistically significant difference in standardized uptake values and uptake ratios between the revision surgery and control groups (p=5.
3× 10−6 and p=0.
0002, respectively).
Conclusions 18F-NaF PET/CT imaging appeared as a useful tool to identify pseudarthrosis following spinal fusion.
The unexpectedly high prevalence (38.
9%) of SSI caused by C.
acnes found in presumed aseptic patients supports the utility of intraoperative cultures in revision cases for pseudarthrosis, even without preoperative clinical suspicion of SSI.
Related Results
Value of 18F-FDG PET/CT to Identify Occult Infection in Presumed Aseptic Pseudarthrosis after Spinal Fusion: Correlation with Intraoperative Cultures
Value of 18F-FDG PET/CT to Identify Occult Infection in Presumed Aseptic Pseudarthrosis after Spinal Fusion: Correlation with Intraoperative Cultures
Abstract
Objective Fluorine-18 fluorodeoxyglucose (18F-FDG) positron emission tomography/computed tomography (PET/CT) has gained attention as an emerging tool in case of ...
Bridging bones
Bridging bones
Chapter 2 presents the evaluation of the feasibility of utilizing whole-body [18F]Fluoride PET/CT for visualizing molecular new bone formation in clinically active PsA patients. Th...
SEMANA DE ENFERMAGEM E SEUS ASPECTOS SOCIAIS NA VALORIZAÇÃO PROFISSIONAL: UM RELATO DE EXPERIÊNCIA DO GRUPO PET-ENFERMAGEM
SEMANA DE ENFERMAGEM E SEUS ASPECTOS SOCIAIS NA VALORIZAÇÃO PROFISSIONAL: UM RELATO DE EXPERIÊNCIA DO GRUPO PET-ENFERMAGEM
A enfermagem é o pilar da assistência pois está na linha de frente do cuidado holístico, todavia esta é estigmatizada e desvalorizada, assim como não possui reconhecimento consider...
Head to Head Comparison of 18F-Fluorocholine and Imaging of Prostate-Specific Membrane Antigen, using 18F-DCFPyL PET/CT, in Patients with Biochemical Recurrence of Prostate Cancer: A Review
Head to Head Comparison of 18F-Fluorocholine and Imaging of Prostate-Specific Membrane Antigen, using 18F-DCFPyL PET/CT, in Patients with Biochemical Recurrence of Prostate Cancer: A Review
Purpose
To analyse diagnostic and therapeutic impact of molecular imaging TNM (miTNM) stage obtained with 18F-DCFPyL versus 18F-Fluorocholine in head to head comparison in bioche...
Nghiên cứu nâng cấp quy trình tổng hợp dược chất phóng xạ 18F-NaF quy mô sản xuất
Nghiên cứu nâng cấp quy trình tổng hợp dược chất phóng xạ 18F-NaF quy mô sản xuất
Mục tiêu: Điều chế DCPX 18F-NaF ổn định ở quy mô sản xuất 1000 ± 100mCi/mẻ. Đối tượng và phương pháp: Đối tượng là DCPX 18F-NaF, sử dụng quy trình hóa tổng hợp 18F-NaF ở quy mô 100...
[18F]Fluoride uptake in various bone types and soft tissues in rat
[18F]Fluoride uptake in various bone types and soft tissues in rat
Abstract
Background: In the development of new 18F-labelled tracers, it is important to assess the amount of released [18F]fluoride taken up in the bones of experimental an...
Rosuvastatin effect on atherosclerotic plaque microcalcification
Rosuvastatin effect on atherosclerotic plaque microcalcification
Abstract
Background and Aims
Atherosclerotic plaque fluorine-18 sodium fluoride (18F-NaF) uptake on positron emission tomography...
Increased aortic valve uptake of sodium fluoride is associated with higher cardiovascular risk: assessing pathophysiology with PET/CT
Increased aortic valve uptake of sodium fluoride is associated with higher cardiovascular risk: assessing pathophysiology with PET/CT
Abstract
Introduction
Positron emission tomography-computed tomography (PET-CT) with 18F-sodium fluoride (18F-NaF) has been used...