Javascript must be enabled to continue!
Applicability of a Heat Recovery Ventilator Retrofit in a Vancouver Residential House
View through CrossRef
Heat recovery systems are increasingly recognized as key energy conservation measures in residential buildings. But their effectiveness is highly sensitive to operational conditions. This study used a calibrated OpenStudio simulation, which is validated against monthly utility data, to investigate the feasibility of implementing a heat recovery ventilator in an existing single-detached house in Vancouver under two scenarios: existing passive ventilation without a heat recovery ventilator versus the proposed balanced mechanical ventilation with a heat recovery ventilator. The findings indicate that employing an HRV in an existing house lacking balanced ventilation would lead to higher annual space heating energy consumption (75.49 GJ electricity and 56.70 GJ natural gas with HRV compared to 73.64 GJ and 52.70 GJ, respectively, without an HRV). Therefore, for existing houses without balanced ventilation, improving the existing building envelope’s airtightness through retrofits should always be carried out before installing a heat recovery ventilator. Additionally, the heat recovery ventilator should be appropriately sized to compensate for any shortfall in natural infiltration to ensure the sufficient indoor air quality while minimizing the outdoor air-induced space heating energy usage. Furthermore, the recommended break-even point of the infiltration rate for the house studied in this work to avoid increased space heating energy use due to the retrofit with a heat recovery ventilator is 0.281 air change per hour.
Title: Applicability of a Heat Recovery Ventilator Retrofit in a Vancouver Residential House
Description:
Heat recovery systems are increasingly recognized as key energy conservation measures in residential buildings.
But their effectiveness is highly sensitive to operational conditions.
This study used a calibrated OpenStudio simulation, which is validated against monthly utility data, to investigate the feasibility of implementing a heat recovery ventilator in an existing single-detached house in Vancouver under two scenarios: existing passive ventilation without a heat recovery ventilator versus the proposed balanced mechanical ventilation with a heat recovery ventilator.
The findings indicate that employing an HRV in an existing house lacking balanced ventilation would lead to higher annual space heating energy consumption (75.
49 GJ electricity and 56.
70 GJ natural gas with HRV compared to 73.
64 GJ and 52.
70 GJ, respectively, without an HRV).
Therefore, for existing houses without balanced ventilation, improving the existing building envelope’s airtightness through retrofits should always be carried out before installing a heat recovery ventilator.
Additionally, the heat recovery ventilator should be appropriately sized to compensate for any shortfall in natural infiltration to ensure the sufficient indoor air quality while minimizing the outdoor air-induced space heating energy usage.
Furthermore, the recommended break-even point of the infiltration rate for the house studied in this work to avoid increased space heating energy use due to the retrofit with a heat recovery ventilator is 0.
281 air change per hour.
Related Results
Current therapeutic strategies for erectile function recovery after radical prostatectomy – literature review and meta-analysis
Current therapeutic strategies for erectile function recovery after radical prostatectomy – literature review and meta-analysis
Radical prostatectomy is the most commonly performed treatment option for localised prostate cancer. In the last decades the surgical technique has been improved and modified in or...
How far can low emission retrofit of terraced housing in Northern Ireland go?
How far can low emission retrofit of terraced housing in Northern Ireland go?
Abstract
With both global and national targets to reduce greenhouse gas (GHG) emissions the improvement of existing buildings will be key to realising these ambition...
Effect of ocean heat flux on Titan's topography and tectonic stresses
Effect of ocean heat flux on Titan's topography and tectonic stresses
INTRODUCTIONThe thermo-mechanical evolution of Titan's ice shell is primarily controlled by the mode of the heat transfer in the ice shell and the amount of heat coming from the oc...
A study to assess the energy savings potential in the ocean going trawler 'Roxana Bank'
A study to assess the energy savings potential in the ocean going trawler 'Roxana Bank'
Increasing fuel prices have forced marine engineers and diesel engine manufacturers to look at methods of. reducing fuel consumption without a loss in output power. Engineers are a...
Magnesium Heat Sink Evaluations
Magnesium Heat Sink Evaluations
<div class="htmlview paragraph">A system has been constructed to estimate heat dissipated from geometrically identical heat sinks and pinfins extruded from magnesium (M1A) an...
Simulation and Economic Research of Circulating Cooling Water Waste Heat and Water Resource Recovery System
Simulation and Economic Research of Circulating Cooling Water Waste Heat and Water Resource Recovery System
Industrial circulating cooling water contains a large amount of low-quality energy, which is lost to the environment through cooling towers. It is of great significance and potenti...
Numerical Evaluation of Clearance Requirements Around Obstructions in Finned Heat Sinks
Numerical Evaluation of Clearance Requirements Around Obstructions in Finned Heat Sinks
This study uses CFD to consider the effects of obstructions (bosses) on the fluid flow and heat transfer in finned heat sinks used for cooling electronic components. In particular,...
Assessment of the Knowledge regarding Ventilator Care Bundle among Final Year BSc. Nursing Students of Mysuru City
Assessment of the Knowledge regarding Ventilator Care Bundle among Final Year BSc. Nursing Students of Mysuru City
Background: Ventilator-associated pneumonia (VAP) is nosocomial pneumonia found in 9–27% of patients on mechanically assisted ventilator and is also a major threat to the recovery ...