Javascript must be enabled to continue!
40Ca+ optical clocks in China
View through CrossRef
In this review, the improvements made in the past two decades for 40Ca+ optical clocks in China are presented. Uncertainty of below 1.3×10−17 was achieved by applying the “magic” RF trapping frequency and introducing a generalized Ramsey excitation scheme. The stability of 40Ca+ optical clocks has been improved to 2.5×10−15/τ with an uptime rate of 93.8% by implementing two ameliorated lock algorithms in the Ramsey excitation scheme. A long-term clock frequency comparison shows a clock stability of 6.3 × 10−18 in an averaging time of 524 000 s. A robust and transportable clock installed in an air-conditioned car trailer can achieve almost the same performance of laboratory clocks. A height difference between transportable and laboratory clocks was measured with an uncertainty of 0.33 m and the absolute frequency of 40Ca+ optical clock transitions was remeasured as 411 042 129 776 400.41(23) Hz, with a fractional uncertainty of 5.6×10−16 based on a Cs fountain clock in the National Institute of Metrology after the transportable clock was transported from Wuhan to Beijing. The author predicts that transportable single-ion optical clocks especially based on the 40Ca+ will make a significant contribution to the construction of a world-wide optical clock network and the redefinition of the unit of time in the future.
American Vacuum Society
Title: 40Ca+ optical clocks in China
Description:
In this review, the improvements made in the past two decades for 40Ca+ optical clocks in China are presented.
Uncertainty of below 1.
3×10−17 was achieved by applying the “magic” RF trapping frequency and introducing a generalized Ramsey excitation scheme.
The stability of 40Ca+ optical clocks has been improved to 2.
5×10−15/τ with an uptime rate of 93.
8% by implementing two ameliorated lock algorithms in the Ramsey excitation scheme.
A long-term clock frequency comparison shows a clock stability of 6.
3 × 10−18 in an averaging time of 524 000 s.
A robust and transportable clock installed in an air-conditioned car trailer can achieve almost the same performance of laboratory clocks.
A height difference between transportable and laboratory clocks was measured with an uncertainty of 0.
33 m and the absolute frequency of 40Ca+ optical clock transitions was remeasured as 411 042 129 776 400.
41(23) Hz, with a fractional uncertainty of 5.
6×10−16 based on a Cs fountain clock in the National Institute of Metrology after the transportable clock was transported from Wuhan to Beijing.
The author predicts that transportable single-ion optical clocks especially based on the 40Ca+ will make a significant contribution to the construction of a world-wide optical clock network and the redefinition of the unit of time in the future.
Related Results
Reassessing Mg/Ca temperature calibrations of Neogloboquadrina pachyderma (sinistral) using paired δ44/40Ca and Mg/Ca measurements
Reassessing Mg/Ca temperature calibrations of Neogloboquadrina pachyderma (sinistral) using paired δ44/40Ca and Mg/Ca measurements
The Mg/Ca temperature calibration of the polar to subpolar planktonic foraminifera Neogloboquadrina pachyderma (sinistral) (sinistral indicates left coiling) was refined by a multi...
Evaluating Optical Clock Performance for GNSS Positioning
Evaluating Optical Clock Performance for GNSS Positioning
Atomic clocks are highly precise timing devices used in numerous Positioning, Navigation, and Timing (PNT) applications on the ground and in outer space. In recent years, however, ...
High Precision Determination of 48Ca/42Ca Ratio by TIMS for Ca Isotope Fractionation Studies
High Precision Determination of 48Ca/42Ca Ratio by TIMS for Ca Isotope Fractionation Studies
For studies of mass‐dependent fractionation of calcium isotopes in natural materials, the 48Ca/42Ca ratio is a superior choice to the conventionally measured 44Ca/40Ca ratio for tw...
Characteristics of the IGS receiver clock performance from multi-GNSS PPP solutions
Characteristics of the IGS receiver clock performance from multi-GNSS PPP solutions
AbstractGlobal navigation satellite system (GNSS) receivers belonging to the International GNSS Service (IGS) are equipped with different types of clocks, such as internal crystal ...
“Epigenetic clocks”: Theory and applications in human biology
“Epigenetic clocks”: Theory and applications in human biology
AbstractAll humans age, but how we age—and how fast—differs considerably from person to person. This deviation between apparent age and chronological age is often referred to as “b...
OmniAge: a compendium of aging omic biomarkers links mitotic clocks to clonal hematopoiesis and causality
OmniAge: a compendium of aging omic biomarkers links mitotic clocks to clonal hematopoiesis and causality
Abstract
Interest in aging ‘omic’ biomarkers has grown due to their ability to quantify biological age. Most of these biomarkers have been derive...
Doklam Standoff Resolution: Interview of Major General S B Asthana by SCMP
Doklam Standoff Resolution: Interview of Major General S B Asthana by SCMP
(Views of Major General S B Asthana,SM,VSM, (Veteran), Questioned by Jiangtao Shi of South China Morning Post on 29 August 2017.Question 1 (SCMP)Are you surprised that the over 70-...
Geochemical fingerprints of dolomitization in Bahamian carbonates: Evidence from sulphur, calcium, magnesium and clumped isotopes
Geochemical fingerprints of dolomitization in Bahamian carbonates: Evidence from sulphur, calcium, magnesium and clumped isotopes
AbstractIn an effort to constrain the mechanism of dolomitization in Neogene dolomites in the Bahamas and improve understanding of the use of chemostratigraphic tracers in shallow‐...

