Javascript must be enabled to continue!
Titanium and Platinum–Fluoroplastic Stapes Prostheses Visualization on Cone Beam Computed Tomography and High-Resolution Computed Tomography
View through CrossRef
Objective: The aim of this study was to evaluate whether stapes prostheses can be visualized with less metal artifacts and therefore more accurately on cone beam computed tomography in comparison to computed tomography imaging. Recent studies have shown that cone beam computed tomography has advantages when imaging metal artifacts. Patients with hearing loss or vertigo, who have undergone stapedotomy, often present a challenge for otologic surgeons. Imaging studies can deliver crucial additional information. Methods: A retrospective analysis of imaging studies and clinical data in a tertiary care center were carried out. Forty-one patients with forty-five implanted ears were evaluated in the study. All included patients had been implanted with a platinum–fluoroplastic (n = 19) or titanium (n = 26) piston and subsequently had undergone imaging months or years after surgery for various reasons. Patients underwent computed tomography or cone beam computed tomography of the temporal bone depending on availability. Piston visualization, prosthesis length, vestibular intrusion and audiologic results were compared between the groups. Piston position on imaging studies were compared to intraoperative findings. Results: Functional length measurements of all prostheses were carried out with a mean error of −0.17 mm (±0.20). Platinum–fluoroplastic protheses were significantly underestimated in length compared to titanium prostheses. To analyze the material-dependent difference in the measurement errors of the imaging techniques the interaction was tested in an ANOVA model and showed no statistically significant result (p = 0.24). The blinded neuroradiologist viewed two implants, both platinum–fluoroplastic pistons, as located outside of the vestibule due to an underestimation of the prothesis length and the missing radiodensity of the lower end of the prosthesis. Conclusion: Surgeons and radiologists should be aware of the different types and radiologic features of stapes prostheses and the missing radiodensity of some protheses parts. Cone beam computed tomography is an imaging alternative with a potential advantage of reduced radiation in patients after stapes surgery suffering from vertigo or hearing loss to evaluate piston position.
Title: Titanium and Platinum–Fluoroplastic Stapes Prostheses Visualization on Cone Beam Computed Tomography and High-Resolution Computed Tomography
Description:
Objective: The aim of this study was to evaluate whether stapes prostheses can be visualized with less metal artifacts and therefore more accurately on cone beam computed tomography in comparison to computed tomography imaging.
Recent studies have shown that cone beam computed tomography has advantages when imaging metal artifacts.
Patients with hearing loss or vertigo, who have undergone stapedotomy, often present a challenge for otologic surgeons.
Imaging studies can deliver crucial additional information.
Methods: A retrospective analysis of imaging studies and clinical data in a tertiary care center were carried out.
Forty-one patients with forty-five implanted ears were evaluated in the study.
All included patients had been implanted with a platinum–fluoroplastic (n = 19) or titanium (n = 26) piston and subsequently had undergone imaging months or years after surgery for various reasons.
Patients underwent computed tomography or cone beam computed tomography of the temporal bone depending on availability.
Piston visualization, prosthesis length, vestibular intrusion and audiologic results were compared between the groups.
Piston position on imaging studies were compared to intraoperative findings.
Results: Functional length measurements of all prostheses were carried out with a mean error of −0.
17 mm (±0.
20).
Platinum–fluoroplastic protheses were significantly underestimated in length compared to titanium prostheses.
To analyze the material-dependent difference in the measurement errors of the imaging techniques the interaction was tested in an ANOVA model and showed no statistically significant result (p = 0.
24).
The blinded neuroradiologist viewed two implants, both platinum–fluoroplastic pistons, as located outside of the vestibule due to an underestimation of the prothesis length and the missing radiodensity of the lower end of the prosthesis.
Conclusion: Surgeons and radiologists should be aware of the different types and radiologic features of stapes prostheses and the missing radiodensity of some protheses parts.
Cone beam computed tomography is an imaging alternative with a potential advantage of reduced radiation in patients after stapes surgery suffering from vertigo or hearing loss to evaluate piston position.
Related Results
Preoperative prediction of stapes exposure during otomicrosurgery based on temporal bone computed tomography images:A cohort observational study
Preoperative prediction of stapes exposure during otomicrosurgery based on temporal bone computed tomography images:A cohort observational study
Introduction:
This prospective study aimed to evaluate the
predictive value of high-resolution computed tomography (CT) scan of the
temporal bone in predicting th...
FACTORS THAT INFLUENCE THE USAGE OF PROSTHESES AMONG PERSONS WITH LOWER LIMB AMPUTATION IN THE KUMASI METROPOLIS
FACTORS THAT INFLUENCE THE USAGE OF PROSTHESES AMONG PERSONS WITH LOWER LIMB AMPUTATION IN THE KUMASI METROPOLIS
There has been numerous technological advancements in dealing with major etiologies of lower limb amputation but lower limb amputation has been on the rise. According to Amoah et a...
Safety and Efficacy of Atezolizumab in Ovarian Cancer
Safety and Efficacy of Atezolizumab in Ovarian Cancer
Abstract
Introduction
Although the efficacy of PD-L1 blockade has been evaluated in analyses that combine pharmacologically distinct antibodies, the specific efficacy and safety of...
Cone Dysfunction Syndromes, Cone Dystrophies, and Cone-Rod Degenerations
Cone Dysfunction Syndromes, Cone Dystrophies, and Cone-Rod Degenerations
Abstract
Predominant abnormalities of cone photoreceptor function are present in retinal disorders previously classified under a number of headings, such as cone dys...
Platinum vs non-platinum chemotherapy for platinum-resistant ovarian cancer: a systematic review and meta-analysis
Platinum vs non-platinum chemotherapy for platinum-resistant ovarian cancer: a systematic review and meta-analysis
Abstract
Background
recurrent ovarian cancer (OC) patients with platinum-free interval (PFI) <6 mo. are usually considered p...
Platinum vs non-platinum chemotherapy for platinum-resistant ovarian cancer: A meta-analysis.
Platinum vs non-platinum chemotherapy for platinum-resistant ovarian cancer: A meta-analysis.
e17551 Background: recurrent ovarian cancer (OC) patients with platinum-free interval (PFI) < 6 mo. are usually considered platinum-resistant and treated with non-platinum chem...
A CROSS-SECTIONAL STUDY OF ARTIFACTS IN CONE BEAM COMPUTED TOMOGRAPHY IMAGES OF PATIENTS IN A HOSPITAL
A CROSS-SECTIONAL STUDY OF ARTIFACTS IN CONE BEAM COMPUTED TOMOGRAPHY IMAGES OF PATIENTS IN A HOSPITAL
Introduction:In the field of dentistry, cone beam computed tomography is frequently used as a method of research. Although it provides a three-dimensional image of the head and nec...
Tympanoplasty with an Intact Stapes Superstructure in Chronic Otitis Media
Tympanoplasty with an Intact Stapes Superstructure in Chronic Otitis Media
BACKGROUND: The objective of our study was to ascertain the functional results in terms of air bone gap (ABG) closure over 4 frequencies (0.5, 1, 2, 3 kHz) in patients with chronic...