Search engine for discovering works of Art, research articles, and books related to Art and Culture
ShareThis
Javascript must be enabled to continue!

The Larry Tube: Customized 3D Printed Laryngectomy Tubes Following Total Laryngectomy

View through CrossRef
Objective: To determine whether a custom laryngectomy tube can improve airway symptoms in total laryngectomy patients with atypical anatomy who are unable to use commercial laryngectomy tubes. Furthermore, to exemplify the power of customizable 3D printed medical devices when combined with the expanded access pathway through the FDA. Methods: A custom-fabricated laryngectomy tube, manufactured at in-house clinical engineering labs, was utilized for each patient following typical laryngectomy tube protocols. All participants had previously undergone a total laryngectomy. Patients were selected based on critical airway obstruction posing potentially life-threatening scenarios while using commercially available laryngectomy tubes. Results: For all patients involved, there were no further airway obstruction complications or events, and they reported a subjective, significant improvement in comfort after placement of the custom laryngectomy tube. Conclusion: Custom laryngectomy tubes can provide patients with atypical anatomy relief from airway obstructions and improve comfort when commercial options fail to address the anatomic restriction. The process used to develop custom laryngectomy tubes may be relevant for other diseases and patients with atypical anatomies through the expanded access pathway.
Title: The Larry Tube: Customized 3D Printed Laryngectomy Tubes Following Total Laryngectomy
Description:
Objective: To determine whether a custom laryngectomy tube can improve airway symptoms in total laryngectomy patients with atypical anatomy who are unable to use commercial laryngectomy tubes.
Furthermore, to exemplify the power of customizable 3D printed medical devices when combined with the expanded access pathway through the FDA.
Methods: A custom-fabricated laryngectomy tube, manufactured at in-house clinical engineering labs, was utilized for each patient following typical laryngectomy tube protocols.
All participants had previously undergone a total laryngectomy.
Patients were selected based on critical airway obstruction posing potentially life-threatening scenarios while using commercially available laryngectomy tubes.
Results: For all patients involved, there were no further airway obstruction complications or events, and they reported a subjective, significant improvement in comfort after placement of the custom laryngectomy tube.
Conclusion: Custom laryngectomy tubes can provide patients with atypical anatomy relief from airway obstructions and improve comfort when commercial options fail to address the anatomic restriction.
The process used to develop custom laryngectomy tubes may be relevant for other diseases and patients with atypical anatomies through the expanded access pathway.

Related Results

Blunt Chest Trauma and Chylothorax: A Systematic Review
Blunt Chest Trauma and Chylothorax: A Systematic Review
Abstract Introduction: Although traumatic chylothorax is predominantly associated with penetrating injuries, instances following blunt trauma, as a rare and challenging condition, ...
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
Environmental Surveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) v2
EnvironmentalSurveillance Protocols for Highly Pathogenic Avian Influenza (HPAI) This comprehensive protocol suite enables systematic environmental surveillance for avian influenza...
Hydrogel and Polyester Ventilation Tubes in an Animal Model
Hydrogel and Polyester Ventilation Tubes in an Animal Model
ProblemDetermine the resorption rate and biocompatibility characteristics of novel cross‐linked hydrogel ventilations tubes and varied formulations of polyester ventilation tubes.M...
J-Tube Design for Flexible Umbilicals
J-Tube Design for Flexible Umbilicals
ABSTRACT The design of J-tubes with one or more bends under functional loads is dictated by a single force TL, the cable tension at the bottom of the J-tube. This...
Evaluation of Additively Manufactured Heat Exchanger Tubes Using Experimental and Conjugate Heat Transfer Analysis
Evaluation of Additively Manufactured Heat Exchanger Tubes Using Experimental and Conjugate Heat Transfer Analysis
Abstract Additive manufacturing offers many benefits for the design and production of gas turbine engine components. Direct metal laser sintering (DMLS) expands the ...
Lectin C gene analysis v1
Lectin C gene analysis v1
Mammalian Tissue Total RNA Purification Protocol by GeneJET RNA Purification Kit (Thermo Scientific, USA) Before starting: • Supplement the required amount of Lysis Buffer with β-...
Transoral robotic total laryngectomy
Transoral robotic total laryngectomy
AbstractObjectives/Hypothesis:Minimally invasive surgery has become the standard of care in many organ systems. Head and neck surgery has incorporated transoral surgery, either las...